Thermo-hydraulic performance of double pass solar air heater duct having semi-circular tubes and perforated blocks as artificial roughness

被引:15
|
作者
Hedau, Ankush [1 ]
Saini, R. P. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Hydro & Renewable Energy, Roorkee 247667, India
关键词
Double pass solar air heater; Perforated block; Artificial roughness; Semi-circular tube; Computational fluid dynamics; Thermo-hydraulic performance; TRANSFER ENHANCEMENT; RECTANGULAR DUCT; TRANSVERSE RIBS; CFD ANALYSIS; CHANNEL; FLOW;
D O I
10.1016/j.renene.2023.01.087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar air heaters (SAH) are used to collect and convert the solar radiations into thermal energy for various thermal applications. Its thermo-hydraulic performance can be improved by using various geometries of artificial roughness that breaks the laminar sublayer on absorber plate. In view of the same, a 3-dimensional computa-tional investigation is conducted to study the heat transfer and friction characteristics of a double pass SAH having transverse semi-circular tubes with rectangular perforated blocks as artificial roughness and its outcomes are reported under the present paper. The investigation is carried out for different parameters such as Reynolds number (Re), tube amplitude to duct-height ratio (a/H), relative blockage-height ratio (e/H) and open area ratio (beta) within a range of 3000-19,000, 0.2 to 0.5, 0.4 to 0.8 and 13%-30%, respectively. The results obtained through CFD simulations are also compared with the experimental results for a typical set of parameters and a maximum percentage deviation for Nusselt number and friction factor are found as 1.82% and 5.28% respec-tively. For a considered range of parameters, the maximum value of thermo-hydraulic performance parameter is achieved as 2.51 corresponds to Re of 3000, a/H of 0.3, e/H of 0.4, and beta of 30%. Based on the obtained results, it is found that the perforated blocks having maximum value of beta and minimum value of e/H results in improved thermo-hydraulic performance of a double pass SAH. The research output of the present study may be useful for designing and optimize the parameters of a double pass SAH for the low temperature applications such as space heating, solar drying and solar air conditioning.
引用
收藏
页码:543 / 562
页数:20
相关论文
共 50 条
  • [1] Performance analysis and optimization of solar air heater with double-pass configuration using perforated blocks and semi-circular tubes as artificial roughness
    Hedau, Ankush
    Singal, S. K.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 53
  • [2] Thermo-hydraulic performance of solar air heater having winglet type roughness element
    Amit Kumar
    Apurba Layek
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 10481 - 10495
  • [3] Thermo-hydraulic performance of solar air heater having winglet type roughness element
    Kumar, Amit
    Layek, Apurba
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (19) : 10481 - 10495
  • [4] Thermo-hydraulic performance of solar air heater having discrete D-shaped ribs as artificial roughness
    Dutt, Nitesh
    Hedau, Ankush Jageshwar
    Kumar, Ashwani
    Awasthi, Mukesh Kumar
    Singh, Varun Pratap
    Dwivedi, Gaurav
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023,
  • [5] Experimental study on thermo-hydraulic performance of a solar air heater with rectangular perforated duct inserts
    Arunkumar, H. S.
    Kumar, Shiva
    Karanth, K. Vasudeva
    SOLAR ENERGY, 2021, 227 : 179 - 189
  • [6] Thermo-hydraulic performance prediction of a solar air heater with circular perforated absorber plate using Artificial Neural Network
    Shetty, Shreyas P.
    Nayak, Sadvidya
    Kumar, Shiva
    Karanth, K. Vasudeva
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 23
  • [7] Thermo-hydraulic performance analysis of solar air heaters having artificial roughness-A review
    Sharma, Sanjay K.
    Kalamkar, Vilas R.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 41 : 413 - 435
  • [8] Thermo-Hydraulic Performance Characteristics and Optimization of Protrusion Rib Roughness in Solar Air Heater
    Alam, Tabish
    Meena, Chandan Swaroop
    Balam, Nagesh Babu
    Kumar, Ashok
    Cozzolino, Raffaello
    ENERGIES, 2021, 14 (11)
  • [9] Optimum thermo-hydraulic performance of solar air heater provided with cubical roughness on the absorber surface
    Nanjundappa, Madhukeshwara
    EXPERIMENTAL HEAT TRANSFER, 2020, 33 (04) : 374 - 387
  • [10] Thermo-hydraulic performance of solar air heater having twisted rib over the absorber plate
    Kumar, Anup
    Layek, Apurba
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 133 : 181 - 195