Perioperative Risk Factors for Bleeding in Adolescents Undergoing Pedicle Screw Instrumentation for Scoliosis

被引:3
|
作者
Soini, Venla [1 ,2 ,3 ]
Syvanen, Johanna [1 ,2 ]
Helenius, Ilkka [4 ,5 ,6 ]
Helenius, Linda [7 ,8 ]
Raitio, Arimatias [1 ,2 ]
机构
[1] Univ Turku, Dept Paediat Surg & Paediat Orthopaed Surg, Savitehtaankatu 5, Turku 20520, Finland
[2] Turku Univ Hosp, Savitehtaankatu 5, Turku 20520, Finland
[3] Vaasa Cent Hosp, Wellbeing Serv Cty Ostrobothn, Dept Surg, Vaasa 65130, Finland
[4] Univ Helsinki, Dept Orthopaed & Traumatol, Helsinki 00029, Finland
[5] Helsinki Univ Hosp, Helsinki 00029, Finland
[6] Helsinki New Childrens Hosp, Dept Paediat Orthopaed Surg, Helsinki 00290, Finland
[7] Turku Univ Hosp, Dept Anaesthesiol & Intens Care, Turku 20521, Finland
[8] Univ Turku, Turku 20521, Finland
来源
CHILDREN-BASEL | 2023年 / 10卷 / 02期
关键词
bleeding; blood loss; hidden blood loss; pediatric orthopedics; scoliosis; neuromuscular scoliosis; idiopathic scoliosis; spinal fusion; POSTERIOR SPINAL-FUSION; INTRAOPERATIVE BLOOD-LOSS; IDIOPATHIC SCOLIOSIS; NEUROMUSCULAR SCOLIOSIS; WOUND DRAIN; SURGERY; CHILDREN; MANAGEMENT; TRANSFUSION; MULTICENTER;
D O I
10.3390/children10020381
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Progressive scoliosis eventually leads to extensive spinal fusion surgery, which carries a risk for significant bleeding. Neuromuscular scoliosis (NMS) patients have an additional inherent risk of major perioperative bleeding. The purpose of our research was to investigate the risk factors for measured (intraoperative, drain output) and hidden blood loss related to pedicle screw instrumentation in adolescents, divided into adolescent idiopathic scoliosis (AIS) and NMS patient groups. A retrospective cohort study with prospectively collected data of consecutive AIS and NMS patients undergoing segmental pedicle screw instrumentation at a tertiary level hospital between 2009 and 2021 was conducted. In total, 199 AIS (mean age 15.8 years, 143 females) and 81 NMS patients (mean age 15.2 years, 37 females) were included in the analysis. In both groups, levels fused, increased operative time, and smaller or larger size of erythrocytes were associated with perioperative blood loss (p < 0.05 for all correlations). In AIS, male sex (p < 0.001) and the number of osteotomies correlated with more drain output. In NMS, levels fused correlated with drain output, p = 0.00180. In AIS, patients' lower preoperative MCV levels (p = 0.0391) and longer operation times, p = 0.0038, resulted into more hidden blood loss, but we did not find any significant risk factors for hidden blood loss in NMS patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Comparison of pedicle screw fixation and hybrid instrumentation in adolescent idiopathic scoliosis
    Cecen, Gultekin Sitki
    Gulabi, Deniz
    Guclu, Bulent
    Cecen, Dilber Aycicek
    Oltulu, Ismail
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2016, 50 (03) : 351 - 355
  • [12] Ponte osteotomies with pedicle screw instrumentation in the treatment of adolescent idiopathic scoliosis
    Shah S.A.
    Dhawale A.A.
    Oda J.E.
    Yorgova P.
    Neiss G.I.
    Holmes Jr. L.
    Gabos P.G.
    Spine Deformity, 2013, 1 (3) : 196 - 204
  • [13] Pedicle screw versus hybrid posterior instrumentation for dystrophic neurofibromatosis scoliosis
    Wang, Jr-Yi
    Lai, Po-Liang
    Chen, Wen-Jer
    Niu, Chi-Chien
    Tsai, Tsung-Ting
    Chen, Lih-Huei
    MEDICINE, 2017, 96 (22)
  • [14] Hybrid versus total pedicle screw instrumentation in patients undergoing surgery for neuromuscular scoliosis A COMPARATIVE STUDY WITH MATCHED COHORTS
    Mattila, M.
    Jalanko, T.
    Puisto, V.
    Pajulo, O.
    Helenius, I. J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (10): : 1393 - 1398
  • [15] Comparative Analysis of Perioperative Differences Between Hybrid Versus Pedicle Screw Instrumentation in Adolescent Idiopathic Scoliosis by Sugerman et al
    Steib, Jean-Paul
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (08): : 447 - 447
  • [16] A retrospective cohort study of bleeding characteristics and hidden blood loss after segmental pedicle screw instrumentation in neuromuscular scoliosis as compared with adolescent idiopathic scoliosis
    Soini, Venla
    Raitio, Arimatias
    Helenius, Ilkka
    Helenius, Linda
    Syvaenen, Johanna
    NORTH AMERICAN SPINE SOCIETY JOURNAL, 2022, 12
  • [17] Comparison of segmental pedicle screw instrumentation versus anterior instrumentation in adolescent idiopathic thoracolumbar and lumbar scoliosis
    Hee, Hwan-Tak
    Yu, Zhi-Rong
    Wong, Hee-Kit
    SPINE, 2007, 32 (14) : 1533 - 1542
  • [18] Perioperative rehabilitation instruction in treatment of scoliosis by vertebra l pedicle screw system
    夏江南
    徐艳萍
    中国临床康复, 2003, (04) : 695 - 695
  • [19] Pedicle Screw Instrumentation for Adult Idiopathic Scoliosis An Improvement Over Hook/Hybrid Fixation
    Rose, Peter S.
    Lenke, Lawrence G.
    Bridwell, Keith H.
    Mulconrey, Daniel S.
    Cronen, Geoffrey A.
    Buchowski, Jacob M.
    Schwend, Richard M.
    Sides, Brenda A.
    SPINE, 2009, 34 (08) : 852 - 857
  • [20] Comparative analysis of pedicle screw versus hybrid instrumentation in adolescent idiopathic scoliosis surgery
    Rafi, Sohail
    Munshi, Naseem
    Abbas, Asad
    Shaikh, Rabia Hassan
    Hashmi, Imtiaz
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2016, 7 (04) : 550 - 553