Monitoring mAb proteoforms in mouse plasma using an automated immunocapture combined with top-down and middle-down mass spectrometry

被引:3
|
作者
Dhenin, Jonathan [1 ,2 ,3 ,4 ]
Lafont, Valerie [3 ]
Dupre, Mathieu [3 ]
Krick, Alain [3 ]
Mauriac, Christine [3 ]
Chamot-Rooke, Julia [1 ,3 ,5 ]
机构
[1] Univ Paris Cte, Inst Pasteur, Mass Spectrometry Biol, CNRS,UAR2024, Paris, France
[2] Sorbonne Paris Cite, Univ Paris Cite, Paris, France
[3] DMPK, Sanofi R&D, Chilly Mazarin, France
[4] DMPK, Sanofi R&D, F-91380 Chilly Mazarin, France
[5] Univ Paris Cite, Mass Spectrometry Biol, CNRS, UAR2024, F-75015 Paris, France
基金
欧盟地平线“2020”;
关键词
immunocapture; middle-down mass spectrometry; monoclonal antibody; proteoforms; top-down mass spectrometry; ELECTRON-TRANSFER DISSOCIATION; INTACT MONOCLONAL-ANTIBODY; HIGH-THROUGHPUT ANTIBODY; STRUCTURAL-ANALYSIS; QUALITY ATTRIBUTES; IN-VIVO; LC-MS; IGG1; DRUG; QUANTITATION;
D O I
10.1002/pmic.202300069
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Monoclonal antibodies (mAbs) have established themselves as the leading biopharmaceutical therapeutic modality. Once the developability of a mAb drug candidate has been assessed, an important step is to check its in vivo stability through pharmacokinetics (PK) studies. The gold standard is ligand-binding assay (LBA) and liquid chromatography-mass spectrometry (LC-MS) performed at the peptide level (bottom-up approach). However, these analytical techniques do not allow to address the different mAb proteoforms that can arise from biotransformation. In recent years, top-down and middle-down mass spectrometry approaches have gained popularity to characterize proteins at the proteoform level but are not yet widely used for PK studies. We propose here a workflow based on an automated immunocapture followed by top-down and middle-down liquid chromatography-tandem mass spectrometry (LC-MS/MS) approaches to characterize mAb proteoforms spiked in mouse plasma. We demonstrate the applicability of our workflow on a large concentration range using pembrolizumab as a model. We also compare the performance of two state-of-the-art Orbitrap platforms (Tribrid Eclipse and Exploris 480) for these studies. The added value of our workflow for an accurate and sensitive characterization of mAb proteoforms in mouse plasma is highlighted.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Characterization of Modified RNA by Top-Down Mass Spectrometry
    Taucher, Monika
    Breuker, Kathrin
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (45) : 11289 - 11292
  • [32] Mass spectrometry: Bottom-up or top-down?
    Chait, Brian T.
    SCIENCE, 2006, 314 (5796) : 65 - 66
  • [33] Intact protein mass spectrometry and top-down proteomics
    Whitelegge, Julian
    EXPERT REVIEW OF PROTEOMICS, 2013, 10 (02) : 127 - 129
  • [34] Top-Down Identification and Characterization of Biomolecules by Mass Spectrometry
    Breuker, Kathrin
    Jin, Mi
    Han, Xuemei
    Jiang, Honghai
    McLafferty, Fred W.
    Journal of the American Society for Mass Spectrometry, 2008, 19 (08): : 1045 - 1053
  • [35] Proteoform characterization based on top-down mass spectrometry
    Zhong, Jiancheng
    Sun, Yusui
    Xie, Minzhu
    Peng, Wei
    Zhang, Chushu
    Wu, Fang-Xiang
    Wang, Jianxin
    BRIEFINGS IN BIOINFORMATICS, 2021, 22 (02) : 1729 - 1750
  • [36] Top-down mass spectrometry of integral membrane proteins
    Whitelegge, Julian
    Halgand, Frederic
    Souda, Puneet
    Zabrouskov, Vlad
    EXPERT REVIEW OF PROTEOMICS, 2006, 3 (06) : 585 - 596
  • [37] Top-down identification and characterization of biomolecules by mass spectrometry
    Breuker, Kathrin
    Jin, Mi
    Han, Xuemei
    Jiang, Honghai
    McLafferty, Fred W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (08) : 1045 - 1053
  • [38] Top-down mass spectrometry analysis of amyloidogenic proteins
    Costello, C. E.
    Theberge, R.
    Kingsbury, J.
    Klimtchuk, E.
    Connors, L. H.
    Skinner, M.
    O'Connor, P. B.
    Chen, L.
    AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2006, 13 : 25 - 25
  • [39] Top-down mass spectrometry of crosslinked functional materials
    Endres, Kevin
    Dilla, Roger
    Becker, Matthew
    Wesdemiotis, Chrys
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [40] Characterization of Insulin Dimers by Top-Down Mass Spectrometry
    Gammelgaard, Simon K.
    Petersen, Steffen B.
    Haselmann, Kim F.
    Nielsen, Peter Kresten
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (08) : 1910 - 1918