Endovascular treatment of intracranial aneurysms using the Derivo Embolization Device: a multicenter experience

被引:5
|
作者
Lourenco, Galileu Chagas [1 ]
Dantas, Francois [1 ]
Carvalho, Tiago Silva E. [1 ]
Rodrigues Firmino, Roberti Uili [1 ]
Filgueiras Filho, Marcelo Quesado [1 ]
Tosello, Renato Tavares [2 ]
Leao, Claudio Jose [3 ]
Piske, Ronie Leo [4 ]
Darwich, Rogerio Zenobio [1 ]
机构
[1] Biocor Inst, Dept Intervent Neuroradiol, Nova Lima, MG, Brazil
[2] Hosp Beneficencia Portuguesa Sao Paulo, Ctr Neuroangiog, Sao Paulo, Brazil
[3] Hosp Geral Goiania Dr Alberto Rassi, Dept Intervent Neuroradiol, Goiania, Go, Brazil
[4] Beneficencia Portuguesa Sao Paulo, Dept Intervent Neuroradiol, Sao Paulo, Brazil
关键词
flow diverter; aneurysm; stroke; stent;
D O I
10.1136/neurintsurg-2022-018648
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Flow diversion is the first-line treatment for several types of intracranial aneurysms. We report on a large series of patients treated with the Derivo Embolization Device who underwent a 1-year angiographic control follow-up. Methods We performed a multicenter retrospective analysis of prospectively collected data, designed to evaluate the clinical and angiographic results of treatment of intracranial aneurysms with the Derivo Flow Diverter. The primary endpoint was complete occlusion of the aneurysm within 12 months, which was evaluated using DSA. The secondary endpoint was the absence of any serious adverse events. Univariate and multivariate logistic regression analyses were performed to analyze the data. Results The study was conducted from December 2016 to September 2019 and enrolled 127 patients with 177 intracranial aneurysms, treated at three different centers. Efficacy at 6 months was 70.1% (122/174) for total occlusion and 87.3% (152/174) for favorable occlusion and, at 12 months, it was 83.3% (145/174) for total occlusion and 97.7% (170/174) for favorable occlusion. Regarding safety concerns, 97.6% (124/127) of patients did not experience severe adverse effects during the follow-up period of 12 months, and there was no procedure-related mortality. Conclusions The Derivo Embolization Device, achieving a total occlusion rate of 83.3% and a favorable occlusion rate of 97.7% in a 1-year angiographic control study of 174 aneurysms with minor morbidity and no intervention-related mortality, is a safe and effective treatment for intracranial aneurysms.
引用
收藏
页码:776 / 780
页数:6
相关论文
共 50 条
  • [31] Treatment of Ruptured Intracranial Aneurysms With the Pipeline Embolization Device
    Chalouhi, Nohra
    Zanaty, Mario
    Whiting, Alex
    Tjoumakaris, Stavropoula
    Hasan, David
    Ajiboye, Norman
    Hann, Shannon
    Rosenwasser, Robert H.
    Jabbour, Pascal
    NEUROSURGERY, 2015, 76 (02) : 165 - 172
  • [32] The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
    Nelson, P. K.
    Lylyk, P.
    Szikora, I.
    Wetzel, S. G.
    Wanke, I.
    Fiorella, D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (12) : S43 - S49
  • [33] The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
    Nelson, P. K.
    Lylyk, P.
    Szikora, I.
    Wetzel, S. G.
    Wanke, I.
    Fiorella, D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 34 - 40
  • [34] Treatment of unruptured intracranial aneurysms with the pipeline embolization device
    Murthy, Santosh B.
    Shah, Shreyansh
    Rao, Chethan P. Venkatasubba
    Bershad, Eric M.
    Suarez, Jose I.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (01) : 6 - 11
  • [35] Preliminary results of intracranial aneurysm treatment with derivo2heal embolization device
    Rueckel, J.
    Ozpeynirci, Y.
    Trumm, C.
    Brem, C.
    Pflaeging, M.
    Fischer, T. D.
    Liebig, T.
    NEURORADIOLOGY, 2024, 66 (10) : 1747 - 1759
  • [36] Treatment of Intracranial Aneurysms With the SILK Embolization Device in a Multicenter Study. A Retrospective Data Analysis
    Manuel Pumar, Jose
    Banguero, Alexandra
    Cuellar, Hugo
    Guimaraens, Leopoldo
    Masso, Javier
    Miralbes, Salvador
    Blanco-Ulla, Miguel
    Vazquez-Herrero, Fernando
    Souto, Miguel
    Gelabert-Gonzalez, Miguel
    NEUROSURGERY, 2017, 81 (04) : 595 - 601
  • [37] The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model
    Ley, D.
    Muehl-Benninghaus, R.
    Yilmaz, U.
    Koerner, H.
    Cattaneo, G. F. M.
    Mailaender, W.
    Kim, Y-J.
    Scheller, B.
    Reith, W.
    Simgen, A.
    CLINICAL NEURORADIOLOGY, 2017, 27 (03) : 335 - 343
  • [38] Single-center experience with the new generation Derivo Embolization Device in ruptured dissecting and blister aneurysms
    Kaschner, Marius Georg
    Petridis, Athanasios
    Turowski, Bernd
    ACTA RADIOLOGICA, 2020, 61 (01) : 37 - 46
  • [39] Treatment of Distal Anterior Circulation Aneurysms With the Pipeline Embolization Device: A US Multicenter Experience
    Lin, Ning
    Lanzino, Giuseppe
    Lopes, Demetrius K.
    Arthur, Adam S.
    Ogilvy, Christopher S.
    Ecker, Robert D.
    Dumont, Travis M.
    Turner, Raymond D.
    Gooch, M. Reid
    Boulos, Alan S.
    Kan, Peter
    Snyder, Kenneth V.
    Levy, Elad I.
    Siddiqui, Adnan H.
    NEUROSURGERY, 2016, 79 (01) : 14 - 22
  • [40] The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model
    D. Ley
    R. Mühl-Benninghaus
    U. Yilmaz
    H. Körner
    G. F. M. Cattaneo
    W. Mailänder
    Y-J. Kim
    B. Scheller
    W. Reith
    A. Simgen
    Clinical Neuroradiology, 2017, 27 : 335 - 343