Plantar pressure gradient and pressure gradient angle are affected by inner pressure of air insole

被引:1
|
作者
Haris, Fahni [1 ,2 ]
Jan, Yih-Kuen [3 ]
Liau, Ben-Yi [4 ]
Hsieh, Chang-Wei [5 ]
Shen, Wei-Cheng [6 ]
Tai, Chien-Cheng [7 ]
Shih, Yin-Hwa [1 ]
Lung, Chi-Wen [3 ,8 ]
机构
[1] Asia Univ, Dept Healthcare Adm, Taichung, Taiwan
[2] Univ Muhammadiyah Yogyakarta, Sch Nursing, Yogyakarta, Indonesia
[3] Univ Illinois, Rehabil Engn Lab, Champaign, IL 61820 USA
[4] Feng Chia Univ, Dept Automatic Control Engn, Taichung, Taiwan
[5] Asia Univ, Dept Comp Sci & Informat Engn, Taichung, Taiwan
[6] Asia Univ, Dept Digital Media Design, Taichung, Taiwan
[7] Taipei Med Univ, Int Ph D Program Cell Therapy & Regenerat Med, Taipei, Taiwan
[8] Asia Univ, Dept Creat Prod Design, Taichung, Taiwan
关键词
diabetic foot ulcer; big toe; metatarsal head; walking exercise; walking duration; FOOT ULCERS; WALKING; RISK; EPIDEMIOLOGY; STRESS; INJURY;
D O I
10.3389/fbioe.2024.1353888
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Clinically, air insoles may be applied to shoes to decrease plantar pressure gradient (PPG) and increase plantar gradient angle (PGA) to reduce foot ulcers. PPG and PGA may cause skin breakdown. The effects of different inner pressures of inflatable air insoles on dynamic PPG and PGA distributions are largely unknown in non-diabetics and people with diabetes. This study aimed to explore the impact of varying inner air insole pressures on PPG and PGA to establish early mitigation strategies for people at risk of foot ulcers. A repeated measures study design, including three air insoles (80 mmHg, 160 mmHg, and 240 mmHg) and two walking durations (10 and 20 min) for a total of six walking protocols, was tested on 13 healthy participants (height, 165.8 +/- 8.4 cm; age, 27.0 +/- 7.3 years; and weight, 56.0 +/- 7.9 kg, BMI: 20.3 +/- 1.7 kg/m<^>2) over three consecutive weeks. PPG, a measurement of the spatial variation in plantar pressure around the peak plantar pressure (PPP) and PGA, a variation in the gradient direction values at the three plantar regions, big toe (T1), first metatarsal head (M1), and second metatarsal head (M2), were calculated. This study indicated that PPG was lower at 80 mmHg air insoles after 20 min of walking in the M1 region (p = 0.010). The PGA in the M2 increased at an air insole of 80 mmHg compared to 240 mmHg (p = 0.015). Compared to 20 min, the 10 min walking duration at 240 mmHg of air insole had the lowest PPG in the M1 (p = 0.015) and M2 (p = 0.034) regions. The 80 mmHg air insole significantly lowered the PPG compared to a 160 mmHg and 240 mmHg air insole. Moreover, the 80 mmHg air insole significantly decreased PPP and increased PGA compared to the 160 mmHg and 240 mmHg air insole. A shorter walking period (10 min) significantly lowered PPG. The findings of this study suggest that people with a higher risk of foot ulcers should wear softer air insoles to have a lower PPG, as well as an increased PGA.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Pressure gradient means flow
    Jueyue Yan
    Zhipeng Xu
    Xujian He
    Chenkan Chen
    Tong Li
    Critical Care, 27
  • [42] COMMENTS ON DIFFUSION IN A PRESSURE GRADIENT
    STEVENS, RN
    DUTTON, R
    SCRIPTA METALLURGICA, 1970, 4 (07): : 509 - &
  • [43] Behavior of a horizontal air curtain subjected to a vertical pressure gradient
    Linden, James
    Phelps, LeEllen
    GROUND-BASED AND AIRBORNE TELESCOPES IV, 2012, 8444
  • [44] Pulsed high-voltage discharge in air with a pressure gradient
    Strikovskiy, A. V.
    Evtushenko, A. A.
    Gushchin, M. E.
    Korobkov, S. V.
    Kostrov, A. V.
    PLASMA PHYSICS REPORTS, 2017, 43 (10) : 1031 - 1038
  • [45] Pulsed high-voltage discharge in air with a pressure gradient
    A. V. Strikovskiy
    A. A. Evtushenko
    M. E. Gushchin
    S. V. Korobkov
    A. V. Kostrov
    Plasma Physics Reports, 2017, 43 : 1031 - 1038
  • [46] PRESSURE-GRADIENT FOR VENOUS RETURN, OR THE PRESSURE-GRADIENT CAUSED BY VENOUS RETURN - REPLY
    LEVY, MN
    CIRCULATION RESEARCH, 1980, 46 (04) : 590 - 591
  • [47] Insole Plantar Pressure Measurement During Quiet Stance Post Stroke
    Hillier, Susan
    Lai, Myra S.
    TOPICS IN STROKE REHABILITATION, 2009, 16 (03) : 189 - 195
  • [48] Design Consideration of Data Acquisition System for Capacitive Plantar Pressure Insole
    Nugroho, Asep
    Gustiandi, Reyhan
    Damayanti, Kristiana Asih
    Rozaqi, Latif
    Sanjaya, Kadek Heri
    Bahrudin
    2022 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET): EMERGING SCIENCE AND INDUSTRIAL INNOVATION IN ELECTRONICS AND TELECOMMUNICATION, 2022, : 1 - 5
  • [49] A Portable Insole System to Simultaneously Measure Plantar Pressure and Shear Stress
    Wang, Lefan
    Jones, Dominic
    Jones, Alexander
    Chapman, Graham J.
    Siddle, Heidi J.
    Russell, David
    Alazmani, Ali
    Culmer, Peter R.
    IEEE SENSORS JOURNAL, 2022, 22 (09) : 9104 - 9113
  • [50] Design and Implementation of a Smart Insole System to Measure Plantar Pressure and Temperature
    Khandakar, Amith
    Mahmud, Sakib
    Chowdhury, Muhammad E. H.
    Reaz, Mamun Bin Ibne
    Kiranyaz, Serkan
    Bin Mahbub, Zaid
    Ali, Sawal Hamid Md
    Bakar, Ahmad Ashrif A.
    Ayari, Mohamed Arselene
    Alhatou, Mohammed
    Abdul-Moniem, Mohammed
    Faisal, Md Ahasan Atick
    SENSORS, 2022, 22 (19)