Plantar pressure gradient and pressure gradient angle are affected by inner pressure of air insole

被引:1
|
作者
Haris, Fahni [1 ,2 ]
Jan, Yih-Kuen [3 ]
Liau, Ben-Yi [4 ]
Hsieh, Chang-Wei [5 ]
Shen, Wei-Cheng [6 ]
Tai, Chien-Cheng [7 ]
Shih, Yin-Hwa [1 ]
Lung, Chi-Wen [3 ,8 ]
机构
[1] Asia Univ, Dept Healthcare Adm, Taichung, Taiwan
[2] Univ Muhammadiyah Yogyakarta, Sch Nursing, Yogyakarta, Indonesia
[3] Univ Illinois, Rehabil Engn Lab, Champaign, IL 61820 USA
[4] Feng Chia Univ, Dept Automatic Control Engn, Taichung, Taiwan
[5] Asia Univ, Dept Comp Sci & Informat Engn, Taichung, Taiwan
[6] Asia Univ, Dept Digital Media Design, Taichung, Taiwan
[7] Taipei Med Univ, Int Ph D Program Cell Therapy & Regenerat Med, Taipei, Taiwan
[8] Asia Univ, Dept Creat Prod Design, Taichung, Taiwan
关键词
diabetic foot ulcer; big toe; metatarsal head; walking exercise; walking duration; FOOT ULCERS; WALKING; RISK; EPIDEMIOLOGY; STRESS; INJURY;
D O I
10.3389/fbioe.2024.1353888
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Clinically, air insoles may be applied to shoes to decrease plantar pressure gradient (PPG) and increase plantar gradient angle (PGA) to reduce foot ulcers. PPG and PGA may cause skin breakdown. The effects of different inner pressures of inflatable air insoles on dynamic PPG and PGA distributions are largely unknown in non-diabetics and people with diabetes. This study aimed to explore the impact of varying inner air insole pressures on PPG and PGA to establish early mitigation strategies for people at risk of foot ulcers. A repeated measures study design, including three air insoles (80 mmHg, 160 mmHg, and 240 mmHg) and two walking durations (10 and 20 min) for a total of six walking protocols, was tested on 13 healthy participants (height, 165.8 +/- 8.4 cm; age, 27.0 +/- 7.3 years; and weight, 56.0 +/- 7.9 kg, BMI: 20.3 +/- 1.7 kg/m<^>2) over three consecutive weeks. PPG, a measurement of the spatial variation in plantar pressure around the peak plantar pressure (PPP) and PGA, a variation in the gradient direction values at the three plantar regions, big toe (T1), first metatarsal head (M1), and second metatarsal head (M2), were calculated. This study indicated that PPG was lower at 80 mmHg air insoles after 20 min of walking in the M1 region (p = 0.010). The PGA in the M2 increased at an air insole of 80 mmHg compared to 240 mmHg (p = 0.015). Compared to 20 min, the 10 min walking duration at 240 mmHg of air insole had the lowest PPG in the M1 (p = 0.015) and M2 (p = 0.034) regions. The 80 mmHg air insole significantly lowered the PPG compared to a 160 mmHg and 240 mmHg air insole. Moreover, the 80 mmHg air insole significantly decreased PPP and increased PGA compared to the 160 mmHg and 240 mmHg air insole. A shorter walking period (10 min) significantly lowered PPG. The findings of this study suggest that people with a higher risk of foot ulcers should wear softer air insoles to have a lower PPG, as well as an increased PGA.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Effects of walking speeds and durations on the plantar pressure gradient and pressure gradient angle
    Lung, Chi-Wen
    Mo, Pu-Chun
    Cao, Chunmei
    Zhang, Keying
    Wu, Fu-Lien
    Liau, Ben-Yi
    Jan, Yih-Kuen
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01) : 823
  • [2] Effects of walking speeds and durations on the plantar pressure gradient and pressure gradient angle
    Chi-Wen Lung
    Pu-Chun Mo
    Chunmei Cao
    Keying Zhang
    Fu-Lien Wu
    Ben-Yi Liau
    Yih-Kuen Jan
    BMC Musculoskeletal Disorders, 23
  • [3] Pressure gradient as an indicator of plantar skin injury
    Mueller, MJ
    Zou, DQ
    Lott, DJ
    DIABETES CARE, 2005, 28 (12) : 2908 - 2912
  • [4] On the angle of deviation between gradient of atmospheric pressure and air motion
    van der Stok, JP
    PROCEEDINGS OF THE KONINKLIJKE AKADEMIE VAN WETENSCHAPPEN TE AMSTERDAM, 1912, 14 : 865 - 875
  • [5] Instrumented rubber insole for plantar pressure sensing
    Motha, Lazarus
    Kim, Jiseok
    Kim, Woo Soo
    ORGANIC ELECTRONICS, 2015, 23 : 82 - 86
  • [6] A PORTABLE INSOLE PLANTAR PRESSURE MEASUREMENT SYSTEM
    WERTSCH, JJ
    WEBSTER, JG
    TOMPKINS, WJ
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1992, 29 (01): : 13 - 18
  • [7] Comparison of Peak Plantar Pressure and Peak Pressure Gradient among Patients with Prediabetes and Diabetes
    Izuora, Kenneth
    Trabia, Mohamed
    Deberardinis, Jessica
    Lidstone, Daniel E.
    Varre, Mathew Sunil
    Trotter, Ashley L.
    Dufek, Janet S.
    DIABETES, 2018, 67
  • [8] GRADIENT PRESSURE
    BRUSTER, JM
    PULLIUM, G
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1983, 37 (07): : 485 - 488
  • [10] Using plantar pressure to predict insole comfort in running
    Yang F.
    Liu Z.-L.
    Ma R.-Y.
    Lam W.-K.
    Footwear Science, 2019, 11 (sup1) : S15 - S17