Evaluation of a hollow fiber membrane contactor reactor for reactive extraction in biodiesel production

被引:0
|
作者
Yaya, Nevardo Bello [1 ,2 ]
Habert, Alberto Claudio [1 ]
de Araujo Kronemberger, Frederico [1 ]
机构
[1] COPPE Fed Univ Rio de Janeiro, Chem Engn Program, BR-21941914 Rio De Janeiro, RJ, Brazil
[2] Av Horacio Macedo 2030,Bloco G,Sala 115, BR-812480 Rio De Janeiro, Brazil
关键词
Process intensification; Reactive extraction; Hollow fiber membrane contactor reactor; Biodiesel; TRANSESTERIFICATION; TECHNOLOGIES; PURIFICATION; REMOVAL; ACID;
D O I
10.1016/j.cep.2023.109574
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A polypropylene hollow fiber membrane contactor reactor (HF-MCR) was used to evaluate the performance of a reactive extraction process for biodiesel production. The process involved the transesterification of soybean oil with methanol, catalyzed by sodium hydroxide. The experimental methodology assessed the impact of oil flow rate and methanol/oil molar ratio on the biodiesel (FAME) production rate, triglyceride reaction rate, and glycerin concentration in the final biodiesel product. The results demonstrated that, by employing a countercurrent configuration, is possible to extract the glycerin from the biodiesel-rich phase with methanol, achieving both the reaction and the separation stages in the same equipment. The best results were obtained at a methanol/ oil molar ratio of 4:1 and an oil flow rate of 0.4 L h-1, leading to a triglyceride conversion rate of 0.14 mol h-1 and a FAME production rate of 0.24 mol h-1, equivalent to 34 % conversion and 56 % yield, respectively. The final biodiesel product showed a low concentration of glycerin, measuring only 0.06 % wt. This investigation highlights the potential of employing membrane contactors technology for the biodiesel production process, reducing the processing time by eliminating the biodiesel/glycerol separation stage, and therefore bringing down the load of downstream purification operations.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] OSMOTIC DISTILLATION AND QUALITY EVALUATION OF SUCROSE, APPLE AND ORANGE JUICES IN HOLLOW FIBER MEMBRANE CONTACTOR
    Rehman, Waheed Ur
    Zeb, Waheed
    Muhammad, Amir
    Ali, Wajid
    Younas, Mohammad
    CHEMICAL INDUSTRY & CHEMICAL ENGINEERING QUARTERLY, 2017, 23 (02) : 217 - 227
  • [32] Liquid-liquid extraction of aroma compounds with hollow fiber contactor
    Baudot, A
    Floury, J
    Smorenburg, HE
    AICHE JOURNAL, 2001, 47 (08) : 1780 - 1793
  • [33] Hydrogen production by glucose reforming using a nickel hollow fiber membrane reactor
    Xue, Kai
    Hu, Zhifei
    Li, Claudia
    Wang, Mingming
    Tan, Xiaoyao
    Wang, Zhigang
    Kawi, Sibudjing
    Meng, Xiangtong
    Qiu, Jieshan
    Liu, Shaomin
    JOURNAL OF MEMBRANE SCIENCE, 2024, 695
  • [34] Cyclodextrin production in hollow fiber membrane reactor system: Effect of substrate preparation
    Sakinah, A. M. Mimi
    Ismail, A. F.
    Illias, R. M.
    Zularisam, A. W.
    Hassan, O.
    Matsuura, T.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2008, 63 (01) : 163 - 171
  • [35] Triple-layer catalytic hollow fiber membrane reactor for hydrogen production
    Maneerung, Thawatchai
    Hidajat, Kus
    Kawi, Sibudjing
    JOURNAL OF MEMBRANE SCIENCE, 2016, 514 : 1 - 14
  • [36] Mass Transfer Simulation of Caffeine Extraction by Subcritical CO2 in a Hollow-Fiber Membrane Contactor
    Shirazian, S.
    Ashrafizadeh, S. N.
    SOLVENT EXTRACTION AND ION EXCHANGE, 2010, 28 (02) : 267 - 286
  • [37] Absorption of Sulfur Dioxide in a Transversal Flow Hollow Fiber Membrane Contactor
    Yu, Hesheng
    Li, Qinghai
    The, Jesse
    Tan, Zhongchao
    CLEAN COAL TECHNOLOGY AND SUSTAINABLE DEVELOPMENT, 2016, : 393 - 399
  • [38] Study on flue gas desulfurization process with hollow fiber membrane contactor
    Chen, Qian-Qiao
    Zhong, Qin
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2010, 24 (01): : 144 - 149
  • [39] Hollow fiber membrane contactor for air humidity control: Modules and membranes
    Kneifel, K
    Nowak, S
    Albrecht, W
    Hilke, R
    Just, R
    Peinemann, KV
    JOURNAL OF MEMBRANE SCIENCE, 2006, 276 (1-2) : 241 - 251
  • [40] Boiler feed water deoxygenation using hollow fiber membrane contactor
    Shao, Jiahui
    Liu, Huifeng
    He, Yiliang
    DESALINATION, 2008, 234 (1-3) : 370 - 377