Functional interaction of aortic valve and ascending aorta in patients after valve-sparing procedures

被引:0
|
作者
Reil, Jan-Christian [1 ,3 ]
Marquetand, Christoph [2 ]
Busch-Tilge, Claudia [3 ]
Ivannikova, Maria [1 ]
Rudolph, Volker [1 ]
Aboud, Anas [3 ]
Ensminger, Stephan [3 ]
Schaefers, Hans-Joachim [4 ]
Stierle, Ulrich [3 ]
Reil, Gert-Hinrich [5 ]
机构
[1] Herz Diabet Zentrum Nordrhein Westphalen, Klin Allgemeine & Interventionelle Kardiolgie, Georgstr 11, D-32545 Bad Oeynhausen, Germany
[2] Univ Herzzentrum Lubeck, Univ klinikum Schleswig Holstein, Med Klin Kardiol Angiol & Internist Intens med 2, Ratzeburger Allee 160, Lubeck, Germany
[3] Univ Herzzentrum Lubeck, Univ klinikum Schleswig Holstein, Klin Herzchirurg, Campus Lubeck Ratzeburger Allee 160, Lubeck, Germany
[4] Univ klinkum Saarlandes, Klin Herz & Thoraxchirurg, Kirrberger Str, D-66421 Homburg, Saar, Germany
[5] Univ klin Innere Med Kardiol, Klinikum Oldenburg, Rahel Strauss Str 10, Oldenburg, Germany
关键词
ENERGY-LOSS INDEX; PRESSURE RECOVERY; DOPPLER ULTRASOUND; STENOSIS; AREA;
D O I
10.1038/s41598-023-42068-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Pressure recovery (PR) is essential part of the post stenotic fluid mechanics and depends on the ratio of EOA/A(A), the effective aortic valve orifice area (EOA) and aortic cross-sectional area (A(A)). In patients with advanced ascending aortic aneurysm and mildly diseased aortic valves, the effect of A(A) on pressure recovery and corresponding functional aortic valve opening area (ELCO) was evaluated before and after valve-sparing surgery (Dacron graft implantation). 66 Patients with ascending aortic aneurysm (mean aortic diameter 57 +/- 10 mm) and aortic valve-sparing surgery (32 reimplantation technique (David), 34 remodeling technique (Yacoub)) were routinely investigated by Doppler echocardiography. Dacron graft with a diameter between 26 and 34 mm were implanted. EOA was significantly declined after surgery (3.4 +/- 0.8 vs. 2.6 +/- 0.9cm(2); p < 0.001). Insertion of Dacron prosthesis resulted in a significant reduction of A(A) (26.7 +/- 10.2 vs. 6.8 +/- 1.1cm(2); p < 0.001) with increased ratio of EOA/A(A) (0.14 +/- 0.05 vs. 0.40 +/- 0.1; p < 0.001) and pressure recovery index (PRI; 0.24 +/- 0.08 vs. 0.44 +/- 0.06; p < 0.0001). Despite reduction of EOA, ELCO (= EOA corrected for PR) increased from 4.0 +/- 1.1 to 5.0 +/- 3.1cm(2) (p < 0.01) with reduction in transvalvular LV stroke work (1005 +/- 814 to 351 +/- 407 mmHg x ml, p < 0.001) after surgery. These effects were significantly better in patients with Yacoub technique than with the David operation. The hemodynamic findings demonstrate a valve-vessel interaction almost entirely caused by a marked reduction in the ascending A(A) with significant PR gain. The greater hemodynamic benefit of the Yacoub technique due to higher EOA values compared to the David technique was evident and may be of clinical relevance.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Development of complications in ascending aorta after aortic valve replacement in patients with bicuspid valve
    Gil, CP
    Tornos, P
    Evangelista, A
    Ferreira, I
    Permanyer, C
    Murtra, M
    Soler-Soler, J
    EUROPEAN HEART JOURNAL, 2001, 22 : 89 - 89
  • [42] Valve-sparing excision of aortic valve papillary fibroelastoma
    Vagefi, PA
    Bates, NR
    Ptaszek, LM
    Adams, MS
    Walker, JD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05): : 1177 - U74
  • [43] Early valve failure after aortic valve-sparing root reconstruction - Commentary
    David, TE
    ANNALS OF THORACIC SURGERY, 1999, 68 (01): : 259 - 259
  • [44] Valve opening and closing dynamics after different aortic valve-sparing operations
    Aybek, T
    Sotiriou, M
    Wöhleke, T
    Miskovic, A
    Simon, A
    Doss, M
    Dogan, S
    Wimmer-Greinecker, G
    Moritz, A
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (01): : 114 - 120
  • [45] Valve-sparing Aortic Root Replacement
    Shimizu, Hideyuki
    Yozu, Ryohei
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 17 (04) : 330 - 336
  • [46] Ascending Aorta Diameter Changes after Aortic Valve Replacement in Elderly Patients with Aortic Valve Stenosis
    Gong, Jiamiao
    An, Kang
    Lin, Hongyuan
    Hou, Jianfeng
    CARDIOLOGY RESEARCH AND PRACTICE, 2022, 2022
  • [47] Valve-sparing aortic root replacement
    Sin, YK
    Pillai, RG
    JOURNAL OF CARDIAC SURGERY, 2000, 15 (06) : 424 - 427
  • [48] Valve-Sparing Aortic Root Reconstruction
    Smith, Robert L.
    Kron, Irving L.
    SURGICAL CLINICS OF NORTH AMERICA, 2009, 89 (04) : 837 - +
  • [49] Valve-sparing aortic root replacement
    Koolbergen, David R.
    Manshanden, Johan S. J.
    Bouma, Berto J.
    Blom, Nico A.
    Mulder, Barbara J. M.
    de Mol, Bas A. J. M.
    Hazekamp, Mark G.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (02) : 348 - 354
  • [50] VALVE-SPARING CORRECTION OF AORTIC INCOMPETENCE
    MOIDL, R
    MORITZ, A
    SIMON, P
    OWEN, AN
    KUPILIK, N
    HAVEL, M
    WOLNER, E
    ZEITSCHRIFT FUR KARDIOLOGIE, 1995, 84 (04): : 264 - 269