Enantiomeric purity analysis of synthetic peptide therapeutics by direct chiral high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

被引:5
|
作者
Strege, Mark A. [1 ]
Oman, Trent J. [1 ]
Risley, Donald S. [1 ]
Muehlbauer, Laura K. [1 ]
Jalan, Ankur [1 ]
Lian, Zhirui Jerry [1 ]
机构
[1] Eli Lilly Co, Lilly Corp Ctr, Lilly Res Labs, Indianapolis, IN 46285 USA
关键词
Native amino acids; Enantioseparation; Synthetic peptide therapeutics; Chiral purity; Method validation feasibility; D-AMINO ACIDS; STATIONARY PHASES; ENANTIOSEPARATION; RACEMIZATION; BIOANALYSIS; IMPURITIES; SEPARATION;
D O I
10.1016/j.jchromb.2023.123638
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The determination of chiral purity is critical to the evaluation of the quality of peptide pharmaceutical products. For synthetic peptides, the undesirable D-isomers can be introduced as impurities in amino acid starting materials and can also be formed during peptide synthesis and in some cases during product shelf life. A chiral high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method is described that facilitates rapid and accurate determination of amino acid chiral purity of a peptide. The peptide is hydrolyzed in deuterated acid to facilitate correction for any racemization occurring during this step of sample preparation, and the amino acids are subsequently separated by chiral chromatography interfaced with ESI-MS/MS for quantitation. The amino acid samples are analyzed directly following hydrolysis using high-low chromatography and extraction of selected ion response, providing efficiency and simplicity by avoiding the derivatization steps and multiple external standards required by traditional methodologies. GMP method vali-dation feasibility is described for all nineteen chiral proteogenic amino acids. The practical application of the chiral HPLC-ESI-MS/MS method was demonstrated through the recovery of D-amino acid substitutions at each residue of an octapeptide across the 0.1-1.0 % range of interest. The method was applied to the analysis of four model peptides, each consisting of 8-14 amino acid residues, and the results were comparable to those provided by traditional testing methods.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] DETERMINATION OF PHENYLETHANOID GLYCOSIDES IN LAGOTIS BREVITUBA MAXIM. BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY
    Li, Chunting
    Liu, Yongqiang
    Abdulla, Rahima
    Aisa, Haji Akber
    Suo, Yourui
    ANALYTICAL LETTERS, 2014, 47 (11) : 1862 - 1873
  • [32] Analysis of cationic surfactants by microbore high-performance liquid chromatography-electrospray mass spectrometry
    Department of Hydrology, University of Bayreuth, 95440 Bayreuth, Germany
    Anal Chem, 23 (5362-5366):
  • [33] Determination of trinexapac in wheat by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hiemstra, M
    De Kok, A
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (20) : 5855 - 5860
  • [34] Analysis of cationic surfactants by microbore high-performance liquid chromatography-electrospray mass spectrometry
    Radke, M
    Behrends, T
    Förster, J
    Herrmann, R
    ANALYTICAL CHEMISTRY, 1999, 71 (23) : 5362 - 5366
  • [35] Studies on the flavones using liquid chromatography-electrospray ionization tandem mass spectrometry
    Wu, W
    Yan, CY
    Li, L
    Liu, ZQ
    Liu, SY
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (02) : 213 - 220
  • [36] Determination of Erythromycin Residue in Fishery Products by High Performance Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Yu Hui-Juan
    Cai You-Qiong
    Hui Yun-Hua
    Liu Ting
    Jiang Chao-Jun
    Shen Xiao-Sheng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (01) : 91 - 94
  • [37] Analysis of corticosteroids by high performance liquid chromatography-electrospray mass spectrometry
    Panusa, A
    Ottaviani, M
    Picardo, M
    Camera, E
    Gagliardi, L
    Chimenti, P
    Granese, A
    Tonelli, D
    ANALYST, 2004, 129 (08) : 719 - 723
  • [39] High-performance liquid chromatography-electrospray ionization mass spectrometry determination of sodium ferulate in human plasma
    Yang, Cheng
    Tian, Yuan
    Zhang, Zunjian
    Xu, Fengguo
    Chen, Yun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (03) : 945 - 950
  • [40] Analyses of butyrophenones and their analogues in whole blood by high-performance liquid chromatography-electrospray tandem mass spectrometry
    Seno, H
    Hattori, H
    Ishii, A
    Kumazawa, T
    Watanabe-Suzuki, K
    Suzuki, O
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 746 (01): : 3 - 9