3D-printed procedural task trainer for the aspiration of penile corpus cavernosa in ischaemic priapism

被引:0
|
作者
Harvey, Steven B. [1 ,2 ]
Bezzina, Andrew J. [3 ]
Mac Partlin, Matthew [4 ]
Caldwell, Janice [3 ]
Short, Leah [3 ]
机构
[1] Wollongong Hosp, Med Imaging Dept, Crown St, Wollongong, NSW 2500, Australia
[2] Univ Wollongong, Fac Engn & Informat Sci, Wollongong, NSW, Australia
[3] Wollongong Hosp, Illawarra Shoalhaven Hlth Educ Ctr, Wollongong, NSW, Australia
[4] Wollongong Hosp, Intens Care Unit, Wollongong, NSW, Australia
关键词
3D printing; additive manufacturing; priapism; task trainer; MANAGEMENT;
D O I
10.1111/1742-6723.14131
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
ObjectiveResults The development and initial clinical assessment of a novel 3D-printed procedural task trainer for the aspiration of penile corpus cavernosa in ischaemic priapism. Methods A task trainer for the aspiration of penile corpus cavernosa was designed and manufactured using commercially available 3D printing equipment. The trainer was assessed in two separate training sessions led by faculty investigators. Participants in the sessions were asked to complete a post-procedure survey with regards to the utility and realism of the task trainer. The participants (n = 14) covered a broad spectrum of clinician types. The trainer was perceived by the participants as being anatomically realistic, and especially while under drapes provided a reasonable facsimile of real clinical setup. The trainer proved resilient to multiple attempts at aspiration by multiple participants. Conclusions Participant and facilitator feedback indicates that the task trainer is a useful platform to train for what is a low frequency, but high stakes, procedure. Small numbers of participants preclude statistical rigour and certainty regarding overall performance of the trainer. However, the uniformity in the responses would suggest that this is indeed a task trainer that is 'fit for purpose'.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 25 条
  • [21] Absolute iodine concentration for dynamic perfusion imaging of the myocardium: improved detection of poststenotic ischaemic in a 3D-printed dynamic heart phantom
    Hammel, Johannes
    Birnbacher, Lorenz
    Makowski, Marcus R.
    Pfeiffer, Franz
    Pfeiffer, Daniela
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2022, 6 (01)
  • [22] Absolute iodine concentration for dynamic perfusion imaging of the myocardium: improved detection of poststenotic ischaemic in a 3D-printed dynamic heart phantom
    Johannes Hammel
    Lorenz Birnbacher
    Marcus R. Makowski
    Franz Pfeiffer
    Daniela Pfeiffer
    European Radiology Experimental, 6
  • [23] The Discriminative Power and Stability of Radiomics Features With Computed Tomography Variations Task-Based Analysis in an Anthropomorphic 3D-Printed CT Phantom
    Jimenez-Del-Toro, Oscar
    Aberle, Christoph
    Bach, Michael
    Schaer, Roger
    Obmann, Markus M.
    Flouris, Kyriakos
    Konukoglu, Ender
    Stieltjes, Bram
    Mueller, Henning
    Depeursinge, Adrien
    INVESTIGATIVE RADIOLOGY, 2021, 56 (12) : 820 - 825
  • [24] Grafting Area Reduction in Peyronie's Disease Surgery: Comparative Assessment Between Double Y Vs iGrafter APP Using 3D-Printed Penile Models
    Tourchi, Ali
    Nascimento, Bruno
    Miranda, Alexandre de Freitas
    Miranda, Eduardo
    Bessa, Jose
    Nahas, William C.
    Sayao Filho, Rogerio
    Srougi, Miguel
    Machado, Bruno
    JOURNAL OF SEXUAL MEDICINE, 2022, 19 (04): : 669 - 675
  • [25] PEYRONIE'S DISEASE SURGERY GRAFTING AREA REDUCTION: A COMPARATIVE ASSESSMENT BETWEEN IGRAFTER APP VS DOUBLE Y USING VALIDATED LOW-COST 3D-PRINTED PENILE MODELS
    Machado, Bruno
    Miranda, Alexandre
    Miranda, Eduardo
    Nascimento, Bruno
    JOURNAL OF SEXUAL MEDICINE, 2023, 20 : 62 - 62