Failure Analysis of Heat Exchanger Tubes

被引:3
|
作者
Saffiudeen, Mohamed Fayas [1 ]
Syed, Abdullah [1 ]
Mohammed, Fasil T. [1 ]
机构
[1] Royal Commiss Jubail & Yanbu, Jubail Tech Inst, Dept Mech Skills, Jubail Ind City, Saudi Arabia
关键词
Heat exchanger; Tube inspection; Eddy current testing; Retubing; Maintenance; PMI inspection;
D O I
10.1007/s11668-023-01679-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This research aimed to investigate the causes of tube failures in a shell-and-tube heat exchanger at an oil and gas plant. The shell side of this heat exchanger (reboiler) is used to heat cooling water, while the tube side is used to generate process vapor. The tube material was made of SA 213 TP 317LM (UNS 31725), and tube sheet material was SA 240 TP 317LM (UNS 31725). This heat exchanger had failed its 91 tubes against 2998 tubes after just over 1.8 years in service. Eddy current testing was carried out on 100% of tubes during the turnaround and found 91 tubes with wall thickness loss between 10 and 54%. A failure investigation was carried out on the leaked tubes by pulling one tube and examined for visual examination and a chemical composition test (PMI testing) to see if the material used met the standard specification. The preliminary cause of the tube failure is change in the tube material grade, and the actual tube material is SA 213 TP 304L instead of the required SA 213 TP 317LM. Poor quality control from the inspection department has resulted in the tubes failing to meet the required standards specification of the heat exchanger. As a significant corrective or remedial action, heat exchanger tubes must be changed to SA 213 TP 317LM based on the requirement after performing 100% ECT.
引用
收藏
页码:1259 / 1264
页数:6
相关论文
共 50 条
  • [11] Corrosion Failure of Aluminum Heat Exchanger Tubes
    Ifezue D.
    Tobins F.H.
    Journal of Failure Analysis and Prevention, 2015, 15 (4) : 541 - 547
  • [12] A corrosion failure analysis of heat exchanger tubes operating in petrochemical refinery
    Rezaei, Milad
    Mahidashti, Zeynab
    Eftekhari, Sajad
    Abdi, Ehsan
    ENGINEERING FAILURE ANALYSIS, 2021, 119
  • [13] Failure analysis of 70/30 cupronickel tubes serving in a heat exchanger
    Tong, Hongtao
    Liu, Xuehui
    Sui, Yongqiang
    Liu, Feng
    Liu, Yapeng
    Li, Xiangbo
    Hou, Jian
    ENGINEERING FAILURE ANALYSIS, 2023, 152
  • [14] Failure Analysis of Stainless Steel Heat Exchanger Tubes in a Petrochemical Plant
    Adnyana, D. N.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2018, 18 (02) : 413 - 422
  • [15] Failure analysis of corroded heat exchanger CuNi tubes from a geothermal plant
    Morake, Joseph B.
    Mutua, James M.
    Ruthandi, Martin M.
    Olakanmi, Eyitayo O.
    Botes, Annelize
    ENGINEERING FAILURE ANALYSIS, 2023, 153
  • [16] Failure and structural analysis: A case history on welded tubes in a naval heat exchanger
    Arrigoni, B
    Zonta, GL
    CASE HISTORIES ON INTEGRITY AND FAILURES IN INDUSTRY, 1999, : 571 - 580
  • [17] Comparative study of heat exchanger tubes failure analysis using ECT and IRIS
    Saffiudeen, Mohamed Fayas
    Syed, Abdullah
    Mohammed, Fasil T.
    Mughal, Mohammad Asghar
    Alamri, Yassir A.
    Alanazi, Mubarak A.
    Interactions, 2024, 245 (01)
  • [18] Failure of heat exchanger tubes in cooling water applications
    van Wijngaarden, R
    RISK, ECONOMY AND SAFETY, FAILURE MINIMISATION AND ANALYSIS: FAILURES 2000, 2000, : 123 - 133
  • [19] Failure of heat exchanger tubes due to localized damage
    Malik, MM
    Salam, I
    Tauqir, A
    ENGINEERING PLASTICITY FROM MACROSCALE TO NANOSCALE PTS 1 AND 2, 2003, 233-2 : 151 - 156
  • [20] Failure Analysis of Duplex Stainless Steel for Heat Exchanger Tubes with Seawater Cooling Medium
    Ardy, Husaini
    Albatros, Thomas
    Sumboja, Afriyanti
    METALS, 2023, 13 (07)