A Dual-Energy Metal Artifact Redcution Method for DECT Image Reconstruction

被引:0
|
作者
Lyu, Tianling [1 ]
Zhao, Wei [2 ,3 ]
Gao, Wei [4 ]
Zhu, Jian [6 ]
Xi, Yan [7 ]
Chen, Yang [4 ,5 ]
Zhu, Wentao [1 ]
机构
[1] Zhejiang Lab, Hangzhou, Peoples R China
[2] Beihang Univ, Sch Phys, Beijing, Peoples R China
[3] Beihang Hangzhou Innovat Inst, Hangzhou, Peoples R China
[4] Southeast Univ, Dept Comp Sci & Technol, Lab Imaging Sci & Technol, Nanjing, Peoples R China
[5] Southeast Univ, Jiangsu Prov Joint Int Res Lab Med Informat Proc, Nanjing, Peoples R China
[6] Shandong First Med Univ, Canc Hosp, Dept Radiat Phys & Technol, Jinan, Peoples R China
[7] Shanghai First Imaging Tech, Shanghai, Peoples R China
关键词
metal artifact reduction; dual-energy CT; material decomposition; NMAR; REDUCTION; CT; ALGORITHM;
D O I
10.1109/EMBC40787.2023.10340221
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Metal implants are one of the culprits for image quality degradation in CT imaging, introducing so-called metal artifacts. With the help of the virtual-monochromatic imaging technique, dual-energy CT has been proven to be effective in metal artifact reduction. However, the virtual monochromatic images with suppressed metal artifacts show reduced CNR compared to polychromatic images. To remove metal artifacts on polychromatic images, we propose a dual-energy NMAR (deNMAR) algorithm in this paper that adds material decomposition to the widely used NMAR framework. The dual energy sinograms are first decomposed into water and bone sinograms, and metal regions are replaced with water on the reconstructed material maps. Prior sinograms are constructed by polyenergetically forward projecting the material maps with corresponding spectra, and they are used to guide metal trace interpolation in the same way as in the NMAR algorithm. We performed experiments on authentic human body phantoms, and the results show that the proposed deNMAR algorithm achieves better performance in tissue restoration compared to other compelling methods. Tissue boundaries become clear around metal implants, and CNR rises to 2.58 from similar to 1.70 on 80 kV images compared to other dual-energy-based algorithms.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Reduction of Metal Artifact with Dual-Energy CT: Virtual Monospectral Imaging with Fast Kilovoltage Switching and Metal Artifact Reduction Software
    Pessis, Eric
    Sverzut, Jean-Michel
    Campagna, Raphael
    Guerini, Henri
    Feydy, Antoine
    Drape, Jean-Luc
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (05) : 446 - 455
  • [22] Impact of covariance modeling in dual-energy spectral CT image reconstruction
    Liu, Yan
    Yu, Zhou
    Zou, Yu
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [23] The utility of dual-energy CT for metal artifact reduction from intracranial clipping and coiling
    Mera Fernandez, D.
    Santos Armentia, E.
    Bustos Fiore, A.
    Villanueva Campos, A. M.
    Utrera Perez, E.
    Souto Bayarri, M.
    RADIOLOGIA, 2018, 60 (04): : 310 - 317
  • [24] A comprehensive dual energy method for CBCT metal artifact reduction
    Ge, Weiwei
    Liu, Zihao
    Cui, Hehe
    Yuan, Xiaogang
    Yang, Yidong
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01):
  • [25] DUAL-ENERGY COMPUTER TOMOGRAPHY (DECT): AN EMERGING TECHNIQUE FOR THE DIAGNOSIS OF GOUT
    Jordan, Kelsey
    Sin, Fang En
    RHEUMATOLOGY, 2019, 58
  • [26] Metal artifact reduction by monoenergetic extrapolation of dual-energy CT in patients with metallic implants
    Lee, Ka Yin Gregory
    Cheng, Hei Man Joyce
    Chu, Chi Yeung
    Tam, Chi Wai Annie
    Kan, Wai Kuen
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [27] Gout tophus detection - A comparison of dual-energy CT(DECT) and histology
    Melzer, R.
    Pauli, C.
    Treumann, T.
    Krauss, B.
    SWISS MEDICAL WEEKLY, 2016, 146 : 10S - 10S
  • [28] A novel image optimization method for dual-energy computed tomography
    Hao, Jia
    Kang, Kejun
    Zhang, Li
    Chen, Zhiqiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 722 : 34 - 42
  • [29] A Novel Image Restoration Method Assisted by Reference Image in Dual-energy CT
    Li, Yuanji
    Zhang, Li
    Kang, Kejun
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [30] Benefits of iterative metal artifact reduction and dual-energy CT towards mitigating artifact in the setting of total shoulder prostheses
    Payam Mohammadinejad
    Francis I. Baffour
    Mark C. Adkins
    Lifeng Yu
    Cynthia H. McCollough
    Joel G. Fletcher
    Katrina N. Glazebrook
    Skeletal Radiology, 2021, 50 : 51 - 58