Drug-Coated Balloon Angioplasty for Carotid Artery In-Stent Restenosis: Case Series

被引:1
|
作者
Eljack, Ammar [1 ]
Shih, Emily [2 ]
Meidan, Talia [1 ,5 ]
Lanfear, Allison [1 ,5 ]
Taha, Mohamed [3 ]
Sayfo, Sameh [1 ]
Gable, Dennis [4 ]
Potluri, Srinivasa [1 ]
机构
[1] Baylor Scott & White Heart Hosp Plano, Dept Cardiol, 1100 Allied Dr, Plano, TX 75093 USA
[2] Baylor Univ Med Ctr, Dept Gen Surg, Dallas, TX USA
[3] Howard Univ, Coll Med, Dept Cardiol, Washington, DC USA
[4] Baylor Scott & White Heart Hosp Plano, Dept Vasc Surg, Plano, TX 75093 USA
[5] Baylor Scott & White Res Inst, Dallas, TX USA
关键词
carotid stent; stenting; drug-coated balloon; in-stent restenosis; balloon angioplasty; restenosis; ELUTING BALLOON;
D O I
10.1177/15266028221120763
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: Few case reports have demonstrated promising results of drug-coated balloons (DCBs) as an emerging management for carotid artery in-stent restenosis (CAISR). Herein, we report 6 cases of CAISR which were treated with a DCB with or without new stent deployment. Background: Carotid artery in-stent restenosis is a high-risk condition with an estimated incidence rate that varies widely from 6% to 40%. Several strategies are available now for the management of the CAISR including conventional balloon angioplasty, plaque modification balloon angioplasty, and new stent placement. Methods: A retrospective review of consecutive patients with a diagnosis of severe CAISR at Baylor Scott & White The Heart Hospital Plano from 2011 to 2021 was performed. This study was approved by the Baylor Scott & White Research Institute institutional review board. Results: Six patients underwent DCB angioplasty with or without stent placement under an embolic protection device. Resolution of CAISR was achieved in all cases with 0% to 10% residual stenosis in all cases. Following the procedure, 1 patient had a brief episode of syncope with balloon inflation with immediate recovery on deflation of the balloon. There were otherwise no significant neurological or cardiac events prior to discharge. All patients were asymptomatic at their follow-up visit with no neurological or cardiac events reported at 12, 24, and 36 months following the procedure. Conclusion: While CAISR treatment remains a challenging condition, our study shows that the use of DCB with or without stent placement is a feasible and promising treatment option when compared with other conventional treatment options. Clinical Impact Carotid artery in-stent restenosis treatment remains a challenging condition. Our study shows that the use of drug coated balloon with or without stent placement is a feasible and promising treatment option when compared with current conventional treatment options.
引用
收藏
页码:305 / 311
页数:7
相关论文
共 50 条
  • [21] Combination of Rotarex Thrombectomy and Drug-Coated Balloon for the Treatment of Femoropopliteal Artery In-Stent Restenosis
    Liao, Chuan-jun
    Song, Sheng-han
    Li, Tan
    Zhang, Yang
    Zhang, Wang-de
    ANNALS OF VASCULAR SURGERY, 2019, 60 : 301 - 307
  • [22] Long-term efficacy of drug-coated balloon for renal artery in-stent restenosis
    Elwany, Mostafa
    Di Palma, Gaetano
    Cortese, Bernardo
    EGYPTIAN HEART JOURNAL, 2018, 70 (01): : 55 - 56
  • [23] Drug-Coated Balloons for In-Stent Restenosis
    Kereiakes, Dean J.
    Kandzari, David E.
    Zidar, James P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (11) : 1391 - 1392
  • [24] A drug-coated balloon effectively treated in-stent restenosis due to a stent fracture
    Oba, Yusuke
    Funayama, Hiroshi
    Fukutomi, Motoki
    Kario, Kazuomi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (02): : 169 - 170
  • [25] A drug-coated balloon effectively treated in-stent restenosis due to a stent fracture
    Yusuke Oba
    Hiroshi Funayama
    Motoki Fukutomi
    Kazuomi Kario
    The International Journal of Cardiovascular Imaging, 2018, 34 : 169 - 170
  • [26] Drug-Coated Balloon Angioplasty for Recurrent Multimetal-Layered In-Stent Restenosis Impact of Previous Stent Fracture
    Miura, Katsuya
    Kadota, Kazushige
    Habara, Seiji
    Kuwayama, Akimune
    Ohya, Masanobu
    Shimada, Takenobu
    Amano, Hidewo
    Kubo, Shunsuke
    Hyodo, Yusuke
    Otsuru, Suguru
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    CIRCULATION, 2016, 134
  • [27] Drug-Coated Balloon Angioplasty for Recurrent Multimetal-Layered In-Stent Restenosis Impact of Previous Stent Fracture
    Miura, Katsuya
    Kadota, Kazushige
    Habara, Seiji
    Kuwayama, Akimune
    Ohya, Masanobu
    Shimada, Takenobu
    Amano, Hidewo
    Kubo, Shunsuke
    Hyodo, Yusuke
    Otsuru, Suguru
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    CIRCULATION, 2016, 134
  • [28] Excimer laser prior to drug-coated balloon treatment of in-stent restenosis
    Alfonso, Fernando
    Rivero, Fernando
    Cortese, Bernardo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 348 : 47 - 49
  • [29] Drug-coated balloon for recurrent in-stent restenosis treatment: A suitable strategy
    Piraino, Davide
    Buccheri, Dario
    Cimino, Giuliana
    Andolina, Giuseppe
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 221 : 1084 - 1086
  • [30] Safety and efficacy of paclitaxel drug-coated balloon in femoropopliteal in-stent restenosis
    Anantha-Narayanan, Mahesh
    Love, Keith
    Nagpal, Sameer
    Sheikh, Azfar Bilal
    Regan, Christopher J.
    Mena-Hurtado, Carlos
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (06) : 533 - 539