An Investigation Into the Effect of Different Static Magnetic Fields of 1.5-T and 3.0-T MRI on the Measurement of Tumor Diameters in Breast Cancer

被引:0
|
作者
Yamamoto, Shinji [1 ]
Okada, Yukinori [2 ]
Yoshida, Nobukiyo [3 ]
Takeshita, Koji [4 ]
Sakurai, Noriko [3 ]
Ichikawa, Atsushi [5 ]
Takimoto, Manabu [1 ]
机构
[1] Tokyo Yamate Med Ctr, Radiol Technol, Tokyo, Japan
[2] St Marianna Univ, Sch Med, Radiat Oncol, Kanagawa, Japan
[3] Niigata Univ Hlth & Welf, Radiol Technol, Niigata, Japan
[4] Tokyo Yamate Med Ctr, Radiol, Tokyo, Japan
[5] Nihon Univ Itabashi Hosp, Radiol Technol, Tokyo, Japan
关键词
breast cancer; tumor measurement; 3.0-t mri; 1.5-t mri; static field;
D O I
10.7759/cureus.52838
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective This study aimed to determine whether differences in the static field strength of 1.5-T and 3.0-T MRI systems affect the diagnostic results of tumor size measurement in breast cancer and to compare them with the results of tumor size in surgical pathology diagnosis. Methods We adopted a retrospective and case-control study design. We included patients with a suspected or confirmed diagnosis of breast cancer who underwent breast MRI at our hospital between January 2017 and March 2023. Diffusion-weighted imaging (DWI), gadolinium-enhanced T1-weighted (Gd-T1WI) MRI, and tumor size from surgical pathology were compared via a significance difference test and correlation analysis between the two groups. In this study, the maximum diameters of the tumor obtained by DWI and Gd-T1WI on 1.5-T and 3.0-T MRI systems were divided by the maximum diameter from surgical pathology diagnosis to arrive at the tumor ratio index. Results A total of 36 patients met the selection criteria: 15 for the 1.5-T system and 21 for the 3.0-T system; all of them were female. The mean ratio of pathological tumor length to diameter measured by MRI for each system showed no significant difference between the groups (p=0.653). For the 1.5-T MRI system, the ratio of tumor length diameter by DWI to that by pathology was 1.042-0.361, and the ratio of tumor length diameter by Gd-T1WI to that by pathology was 1.107-0.314, with no significant difference observed between ratios (p=0.345). The correlation coefficient between them was r=0.730 (p=0.002). For the 3.0-T MRI system, the ratio of tumor length diameter by DWI to that by pathology was 0.893-0.197, while the ratio of tumor length diameter by Gd-T1WI to that by pathology was 1.062-0.177, with a significant difference between the two (p<0.001). The correlation coefficient between the two groups was 0.695 (p<0.001). Conclusions While there was no significant difference in the ratios of tumor length diameter measured by 1.5-T Gd-T1WI and DWI compared to pathology, there was a significant difference in the ratios of tumor length diameter measured by 3.0-T DWI and Gd-T1WI compared to pathology. Hence, only 3.0-T DWI can lead to a potential underestimation of tumor length.
引用
收藏
页数:7
相关论文
共 35 条
  • [21] Investigation of the optimal b-value to detect breast tumors with diffusion weighted imaging by 1.5-T MRI
    Tamura, Takayuki
    Murakami, Shigeru
    Naito, Kumiko
    Yamada, Tamaki
    Fujimoto, Takashi
    Kikkawa, Takeshi
    CANCER IMAGING, 2014, 14
  • [22] Investigation of the optimal b-value to detect breast tumors with diffusion weighted imaging by 1.5-T MRI
    Takayuki Tamura
    Shigeru Murakami
    Kumiko Naito
    Tamaki Yamada
    Takashi Fujimoto
    Takeshi Kikkawa
    Cancer Imaging, 14
  • [23] Evaluation of 3.0-T MRI Brain Signal after Exposure to Gadoterate Meglumine in Women with High Breast Cancer Risk and Screening Breast MRI
    Bennani-Baiti, Barbara
    Krug, Barbara
    Giese, Daniel
    Hellmich, Martin
    Bartsch, Sophie
    Helbich, Thomas H.
    Baltzer, Pascal A. T.
    RADIOLOGY, 2019, 293 (03) : 523 - 530
  • [24] THE EFFECTS OF STATIC 3.0-T AND 0.5-T MAGNETIC-FIELDS AND THE ECHO-PLANAR IMAGING EXPERIMENT AT 0.5-T ON ESCHERICHIA-COLI
    MAHDI, A
    GOWLAND, PA
    MANSFIELD, P
    COUPLAND, RE
    LLOYD, RG
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (802): : 983 - 987
  • [25] Breast MRI at 3.0 T in a high-risk familial breast cancer screening cohort: comparison with 1.5 T screening studies
    Pickles, M. D.
    Turnbull, L. W.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015): : 990 - 995
  • [26] Increased Specificity for Detection of Invasive Breast Cancer Using Combined High-resolution 3.0-T MRI and Vascular Mapping of the Breast
    Schmitz, A. C.
    Peters, N.
    Mali, W. P.
    van Diest, P. J.
    van den Bosch, M. A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [27] A health and safety model for occupational exposure to radiofrequency fields and static magnetic fields from 1.5 and 3 T MRI scanners
    P. Rathebe
    C. Weyers
    F. Raphela
    Health and Technology, 2020, 10 : 39 - 50
  • [28] A health and safety model for occupational exposure to radiofrequency fields and static magnetic fields from 1.5 and 3 T MRI scanners
    Rathebe, P.
    Weyers, C.
    Raphela, F.
    HEALTH AND TECHNOLOGY, 2020, 10 (01) : 39 - 50
  • [29] Effect of 0.35 T and 1.5 T magnetic fields on superficial dose in MR-guided radiotherapy of laryngeal cancer
    Conrad, Mireille
    Dal Bello, Riccardo
    van Timmeren, Janita E.
    Andratschke, Nicolaus
    Wilke, Lotte
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    Balermpas, Panagiotis
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2023, 40
  • [30] T1 Relaxation Measurement of Ex-Vivo Breast Cancer Tissues at Ultralow Magnetic Fields
    Lee, Seong-Joo
    Shim, Jeong Hyun
    Kim, Kiwoong
    Hwang, Seong-min
    Yu, Kwon Kyu
    Lim, Sanghyun
    Han, Jae Ho
    Yim, Hyunee
    Kim, Jang-Hee
    Jung, Yong Sik
    Kim, Ku Sang
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015