An Investigation Into the Effect of Different Static Magnetic Fields of 1.5-T and 3.0-T MRI on the Measurement of Tumor Diameters in Breast Cancer

被引:0
|
作者
Yamamoto, Shinji [1 ]
Okada, Yukinori [2 ]
Yoshida, Nobukiyo [3 ]
Takeshita, Koji [4 ]
Sakurai, Noriko [3 ]
Ichikawa, Atsushi [5 ]
Takimoto, Manabu [1 ]
机构
[1] Tokyo Yamate Med Ctr, Radiol Technol, Tokyo, Japan
[2] St Marianna Univ, Sch Med, Radiat Oncol, Kanagawa, Japan
[3] Niigata Univ Hlth & Welf, Radiol Technol, Niigata, Japan
[4] Tokyo Yamate Med Ctr, Radiol, Tokyo, Japan
[5] Nihon Univ Itabashi Hosp, Radiol Technol, Tokyo, Japan
关键词
breast cancer; tumor measurement; 3.0-t mri; 1.5-t mri; static field;
D O I
10.7759/cureus.52838
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective This study aimed to determine whether differences in the static field strength of 1.5-T and 3.0-T MRI systems affect the diagnostic results of tumor size measurement in breast cancer and to compare them with the results of tumor size in surgical pathology diagnosis. Methods We adopted a retrospective and case-control study design. We included patients with a suspected or confirmed diagnosis of breast cancer who underwent breast MRI at our hospital between January 2017 and March 2023. Diffusion-weighted imaging (DWI), gadolinium-enhanced T1-weighted (Gd-T1WI) MRI, and tumor size from surgical pathology were compared via a significance difference test and correlation analysis between the two groups. In this study, the maximum diameters of the tumor obtained by DWI and Gd-T1WI on 1.5-T and 3.0-T MRI systems were divided by the maximum diameter from surgical pathology diagnosis to arrive at the tumor ratio index. Results A total of 36 patients met the selection criteria: 15 for the 1.5-T system and 21 for the 3.0-T system; all of them were female. The mean ratio of pathological tumor length to diameter measured by MRI for each system showed no significant difference between the groups (p=0.653). For the 1.5-T MRI system, the ratio of tumor length diameter by DWI to that by pathology was 1.042-0.361, and the ratio of tumor length diameter by Gd-T1WI to that by pathology was 1.107-0.314, with no significant difference observed between ratios (p=0.345). The correlation coefficient between them was r=0.730 (p=0.002). For the 3.0-T MRI system, the ratio of tumor length diameter by DWI to that by pathology was 0.893-0.197, while the ratio of tumor length diameter by Gd-T1WI to that by pathology was 1.062-0.177, with a significant difference between the two (p<0.001). The correlation coefficient between the two groups was 0.695 (p<0.001). Conclusions While there was no significant difference in the ratios of tumor length diameter measured by 1.5-T Gd-T1WI and DWI compared to pathology, there was a significant difference in the ratios of tumor length diameter measured by 3.0-T DWI and Gd-T1WI compared to pathology. Hence, only 3.0-T DWI can lead to a potential underestimation of tumor length.
引用
收藏
页数:7
相关论文
共 35 条
  • [1] Multicenter Reproducibility of Liver Iron Quantification with 1.5-T and 3.0-T MRI
    Hernando, Diego
    Zhao, Ruiyang
    Yuan, Qing
    Ghasabeh, Mounes Aliyari
    Ruschke, Stefan
    Miao, Xinran
    Karampinos, Dimitrios C.
    Mao, Lu
    Harris, David T.
    Mattison, Ryan J.
    Jeng, Michael R.
    Pedrosa, Ivan
    Kamel, Ihab R.
    Vasanawala, Shreyas
    Yokoo, Takeshi
    Reeder, Scott B.
    RADIOLOGY, 2023, 306 (02)
  • [2] 1.5-T and 3.0-T Magnetic Resonance Imaging Artifacts from Breast Biopsy Clips
    Le-Petross, H.
    Carkaci, S.
    Stafford, R.
    Elliott, A.
    Jackson, E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [3] Performance Comparison of 1.5-T Endorectal Coil MRI with 3.0-T Nonendorectal Coil MRI in Patients with Prostate Cancer
    Shah, Zarine K.
    Elias, Saba N.
    Abaza, Ronney
    Zynger, Debra L.
    DeRenne, Lawrence A.
    Knopp, Michael V.
    Guo, Beibei
    Schurr, Ryan
    Heymsfield, Steven B.
    Jia, Guang
    ACADEMIC RADIOLOGY, 2015, 22 (04) : 467 - 474
  • [4] Comparison between 1.5-T and 3.0-T MRI for the diagnosis of placenta accreta spectrum disorders
    Bourgioti, Charis
    Zafeiropoulou, Konstantina
    Tzavara, Chara
    Daskalakis, George
    Fotopoulos, Stavros
    Theodora, Marianna
    Nikolaidou, Maria Evangelia
    Konidari, Marianna
    Gourtsoyianni, Sofia
    Panourgias, Evangelia
    Koutoulidis, Vassilis
    Martzoukos, Epameinondas Anastasios
    Konstantinidou, Anastasia Evangelia
    Moulopoulos, Lia Angela
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (09) : 408 - 417
  • [5] Effect of 1.5-T and 3.0-T magnetic resonance imaging on the ceramic adhesion and physical properties of prosthetic substructures
    Baysal, Nurten
    Ayyildiz, Simel
    Orujalipoor, Ilghar
    Erol, Baris Filiz
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 809.e1 - 809.e7
  • [6] Specific Absorption Rate and Specific Energy Dose: Comparison of 1.5-T versus 3.0-T Fetal MRI
    Barrera, Christian A.
    Francavilla, Michael L.
    Serai, Suraj D.
    Edgar, J. Christopher
    Jaimes, Camilo
    Gee, Michael S.
    Roberts, Timothy P. L.
    Otero, Hansel J.
    Adzick, N. Scott
    Victoria, Teresa
    RADIOLOGY, 2020, 295 (03) : 664 - 674
  • [7] Exposure levels of radiofrequency magnetic fields and static magnetic fields in 1.5 and 3.0 T MRI units
    Rathebe, P.
    Weyers, C.
    Raphela, F.
    SN APPLIED SCIENCES, 2021, 3 (02):
  • [8] Exposure levels of radiofrequency magnetic fields and static magnetic fields in 1.5 and 3.0 T MRI units
    P. Rathebe
    C. Weyers
    F. Raphela
    SN Applied Sciences, 2021, 3
  • [9] MRI safety for leave-on powdered hair thickeners under 1.5-T and 3.0-T MRI: measurement of deflection force, MRI artifact, and evaluation of preexamination screening
    Sato, Yusuke
    Takeuchi, Tomokazu
    Fuju, Atsuya
    Takahashi, Masahiko
    Hashimoto, Maiko
    Okawa, Ryuya
    Hayashi, Norio
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) : 915 - 924
  • [10] MRI safety for leave-on powdered hair thickeners under 1.5-T and 3.0-T MRI: measurement of deflection force, MRI artifact, and evaluation of preexamination screening
    Yusuke Sato
    Tomokazu Takeuchi
    Atsuya Fuju
    Masahiko Takahashi
    Maiko Hashimoto
    Ryuya Okawa
    Norio Hayashi
    Physical and Engineering Sciences in Medicine, 2023, 46 : 915 - 924