Feasibility study on the clinical application of CT-based synthetic brain T1-weighted MRI: comparison with conventional T1-weighted MRI

被引:2
|
作者
Li, Zhaotong [1 ]
Cao, Gan [2 ]
Zhang, Li [3 ]
Yuan, Jichun [4 ]
Li, Sha [5 ]
Zhang, Zeru [5 ]
Wu, Fengliang [6 ]
Gao, Song [5 ]
Xia, Jun [4 ]
机构
[1] Nantong Univ, Med Sch, Dept Med Informat, Lab Digital Med, Nantong, Peoples R China
[2] Longgang Cent Hosp Shenzhen, Dept Radiol, Shenzhen, Peoples R China
[3] Shenzhen Univ, South China Hosp, Hlth Sci Ctr, Dept Radiol, Shenzhen, Peoples R China
[4] Shenzhen Univ, Shenzhen Peoples Hosp 2, Affiliated Hosp 1, Hlth Sci Ctr,Dept Radiol, Shenzhen, Peoples R China
[5] Peking Univ, Hlth Sci Ctr, Inst Med Technol, Beijing, Peoples R China
[6] Peking Univ Third Hosp, Engn Res Ctr Bone & Joint Precis Med, Dept Orthoped, Beijing Key Lab Spinal Dis Res, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Computed tomography; Magnetic resonance imaging; Deep learning; Synthetic T1-weighted imaging; Brain; AGREEMENT;
D O I
10.1007/s00330-023-10534-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThis study aimed to examine the equivalence of computed tomography (CT)-based synthetic T1-weighted imaging (T1WI) to conventional T1WI for the quantitative assessment of brain morphology.Materials and methodsThis prospective study examined 35 adult patients undergoing brain magnetic resonance imaging (MRI) and CT scans. An image synthesis method based on a deep learning model was used to generate synthetic T1WI (sT1WI) from CT data. Two senior radiologists used sT1WI and conventional T1WI on separate occasions to independently measure clinically relevant brain morphological parameters. The reliability and consistency between conventional and synthetic T1WI were assessed using statistical consistency checks, comprising intra-reader, inter-reader, and inter-method agreement.ResultsThe intra-reader, inter-reader, and inter-method reliability and variability mostly exhibited the desired performance, except for several poor agreements due to measurement differences between the radiologists. All the measurements of sT1WI were equivalent to that of T1WI at 5% equivalent intervals.ConclusionThis study demonstrated the equivalence of CT-based sT1WI to conventional T1WI for quantitatively assessing brain morphology, thereby providing more information on imaging diagnosis with a single CT scan.Clinical relevance statementReal-time synthesis of MR images from CT scans reduces the time required to acquire MR signals, improving the efficiency of the treatment planning system and providing benefits in the clinical diagnosis of patients with contraindications such as presence of metal implants or claustrophobia.Key Points center dot Deep learning-based image synthesis methods generate synthetic T1-weighted imaging from CT scans.center dot The equivalence of synthetic T1-weighted imaging and conventional MRI for quantitative brain assessment was investigated.center dot Synthetic T1-weighted imaging can provide more information per scan and be used in preoperative diagnosis and radiotherapy.Key Points center dot Deep learning-based image synthesis methods generate synthetic T1-weighted imaging from CT scans.center dot The equivalence of synthetic T1-weighted imaging and conventional MRI for quantitative brain assessment was investigated.center dot Synthetic T1-weighted imaging can provide more information per scan and be used in preoperative diagnosis and radiotherapy.Key Points center dot Deep learning-based image synthesis methods generate synthetic T1-weighted imaging from CT scans.center dot The equivalence of synthetic T1-weighted imaging and conventional MRI for quantitative brain assessment was investigated.center dot Synthetic T1-weighted imaging can provide more information per scan and be used in preoperative diagnosis and radiotherapy.
引用
收藏
页码:5783 / 5799
页数:17
相关论文
共 50 条
  • [31] Segmentation of cervical Lymph Nodes in T1-weighted MRI Images
    Jung, Florian
    Hilpert, Julia
    Wesarg, Stefan
    BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 353 - 358
  • [32] Generating Synthetic CT From T1-Weighted Brain MRI Using a Linear Mixed-Effects Regression Model
    Pandey, A.
    Yoganathan, S.
    Guo, B.
    Zhang, R.
    MEDICAL PHYSICS, 2022, 49 (06) : E421 - E421
  • [33] Spacial Aliasing Artefact Detection on T1-Weighted MRI Images
    Teixeira, Joao F.
    Oliveira, Helder P.
    PATTERN RECOGNITION AND IMAGE ANALYSIS (IBPRIA 2017), 2017, 10255 : 462 - 470
  • [34] Comparison of vertebral morphometry in the lumbar vertebrae by T1-weighted sagittal MRI and radiograph
    Tomomitsu, T
    Murase, K
    Sone, T
    Fukunaga, M
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 56 (01) : 102 - 106
  • [35] Corticomedullary differentiation on T1-Weighted MRI: Comparison between cirrhotic and noncirrhotic patients
    Lee, Karen S.
    Munoz, Amelia
    Bello Baez, Adan
    Ngo, Long
    Rofsky, Neil M.
    Pedrosa, Ivan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (03) : 644 - 649
  • [36] Reliability of spinal cord measures based on synthetic T1-weighted MRI derived from (MPM)
    Schading, Simon
    Seif, Maryam
    Leutritz, Tobias
    Hupp, Markus
    Curt, Armin
    Weiskopf, Nikolaus
    Freund, Patrick
    NEUROIMAGE, 2023, 271
  • [37] Conventional T1-weighted imaging in the diagnosis and assessment of brain abscesses
    Holz, AJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (05) : 1298 - 1300
  • [38] MRI of spinal hardware: comparison of conventional T1-weighted sequence with a new metal artifact reduction sequence
    Chang, SD
    Lee, MJ
    Munk, PL
    Janzen, DL
    MacKay, A
    Xiang, QS
    SKELETAL RADIOLOGY, 2001, 30 (04) : 213 - 218
  • [39] MRI of spinal hardware: comparison of conventional T1-weighted sequence with a new metal artifact reduction sequence
    Silvia D. Chang
    M. J. Lee
    Peter L. Munk
    Dennis L. Janzen
    Alex MacKay
    Qing-San Xiang
    Skeletal Radiology, 2001, 30 : 213 - 218
  • [40] Reconstruction of Brain Tissue Surface Based on Three-Dimensional T1-Weighted MRI Images
    Lv, Wenchao
    Peng, Yahui
    Yang, Chao
    Li, Xinchun
    2015 8TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), 2015, : 481 - 486