Type Ic Endoleak after LifeStream Balloon-Expandable Stent Graft and Zenith Iliac Branch Device Placement

被引:1
|
作者
Kim, Hyeon Ju [1 ]
Yun, Woo-Sung [1 ]
Kim, Hyung-Kee [2 ]
机构
[1] Kyungpook Natl Univ Hosp, Div Vasc Surg, Dept Surg, Daegu, South Korea
[2] Kyungpook Natl Univ, Kyungpook Natl Univ Chilgok Hosp, Sch Med, Dept Surg,Div Vasc Surg, Daegu, South Korea
关键词
Iliac aneurysm; Abdominal aortic aneurysm; Endovascular aneurysm repair; Endoleak; ENDOVASCULAR REPAIR; ANATOMIC SUITABILITY; ANEURYSMS; OUTCOMES;
D O I
10.5758/vsi.230002
中图分类号
R61 [外科手术学];
学科分类号
摘要
Considering the recent advancements in endovascular management of aortoiliac aneurysms, the use of an iliac branch device (IBD) to preserve pelvic blood flow and reduce complications caused by embolization of the internal iliac artery (IIA) is recommended by various guidelines. Although the outcomes reported following IBD placement are mainly positive and durable, IBD-specific complications such as a type Ic endoleak and associated reintervention may occur. Moreover, only one IBD device and one type of balloon-expandable bridging stent graft for IIA are currently available on the domestic market. Here we present two cases of type Ic endoleak following IBD placement. In both cases, IIA diameter was slightly larger than the basic instructions for use. Notably, the initial procedures were considered successful; however, type Ic endoleaks were detected on 1-month follow-up imaging. This finding emphasizes the need for a precise preoperative evaluation, intraoperative manipulation, and postoperative follow-up.
引用
收藏
页数:7
相关论文
共 34 条
  • [31] Late distal perigraft endoleak after endovascular repair of an abdominal aortic aneurysm due to cranial migration of the iliac branch of a modular stent-graft
    Maleux, G
    Nevelsteen, A
    Stockx, L
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (02): : 156 - 157
  • [32] Management of Refractory Hepatic Encephalopathy After Insertion of TIPS: Long-Term Results of Shunt Reduction With Hourglass-Shaped Balloon-Expandable Stent-Graft
    Fanelli, Fabrizio
    Salvatori, Filippo Maria
    Rabuffi, Paolo
    Boatta, Emanuele
    Riggio, Oliviero
    Lucatelli, Pierleone
    Passariello, Roberto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1696 - 1702
  • [33] Translumbar repair of a type II endoleak associated with an aorta-to-left renal vein fistula after aortic stent-graft placement
    Resnick, S
    Rome, V
    Eskandari, M
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (03) : 557 - 561
  • [34] Successful type II endoleak closure by subclavian-to-carotid artery transposition after stent-graft placement of a distal aortic arch aneurysm
    Zimpfer, D
    Schoder, M
    Fleck, T
    Holzenbein, T
    Cejna, M
    Lammer, J
    Wolner, E
    Grabenwoger, M
    Czerny, M
    THORACIC AND CARDIOVASCULAR SURGEON, 2005, 53 (05): : 322 - 324