Impact of self-tonometry on glaucoma treatment decision

被引:6
|
作者
Querat, Laurence [1 ,2 ]
Chen, Enping [1 ,2 ]
机构
[1] Karolinska Inst, Div Eye & Vis, Dept Clin Neurosci, Stockholm, Sweden
[2] St Erik Eye Hosp, Dept Anterior Segment Disorders Glaucoma Neurooph, Solna, Sweden
关键词
glaucoma treatment; Goldmann applanation tonometry; iCare (R) Home; intraocular pressure; self-tonometry; INDEPENDENT RISK-FACTOR; NORMAL OFFICE HOURS; INTRAOCULAR-PRESSURE; OCULAR HYPERTENSION; PROGRESSION; FLUCTUATIONS; MANAGEMENT; 24-HOUR;
D O I
10.1111/aos.15256
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to examine the impact of self-tonometry on clinicians' decision in glaucoma treatment. Materials and Methods: Medical records of 133 patients who had performed self-tonometry using iCare (R) Home between January and December 2019 were retrospectively reviewed. Inclusion criteria were as follows: age over 18 years, all types of glaucoma, as well as ocular hypertension and glaucoma suspect, compliance with tonometer manufacturer's recommendations and monitoring over at least 2 days. The data consisted of age, gender, diagnosis, visual field index, rate of progression and type of treatment pre- and post-intraocular pressure (IOP) phasing. The following TOP measurements were used to calculate the mean and maximum IOP, and range over each day and consecutive days: Goldmann applanation tonometry (GAT) measurements from referral and training visits and iCare (R) Home measurements made by the trainers and the patients themselves. A total of 90 patients were included. Results: Clinicians were satisfied with the actual treatment in 54.4% of the cases. There was a statistically significant difference between the clinicians' decision to maintain same treatment or to escalate therapy for all the mean and maximum IOPs measured on each single day and over a 2- or 3-day period (p <0.002). Conclusion: Our results suggest that the presence of high IOP values obtained with self-tonometry supports an intensification of glaucoma treatment. Self-tonometry provides clinicians with an important complement for clinical decision-making, and under- or over-treatment may be avoided for the benefit of patients.
引用
收藏
页码:E246 / E251
页数:6
相关论文
共 50 条
  • [21] Telematically assisted self-tonometry (TAS) - Response
    Michelson, G
    OPHTHALMOLOGE, 2005, 102 (06): : 625 - 626
  • [22] Self-tonometry in Glaucoma Management-Past, Present and Future (vol 54, pg 450, 2009)
    Liang, S. Y. -W.
    Lee, G. A.
    Shields, D.
    SURVEY OF OPHTHALMOLOGY, 2009, 54 (05) : 642 - 642
  • [23] Application of rebound self-tonometry for measurements in a supine position
    Amani, Afsaneh
    Rosentreter, Andre
    Dietlein, Thomas
    Hoerster, Robert
    OPHTHALMOLOGE, 2019, 116 (08): : 766 - 770
  • [24] Weekly fluctuation of intraocular pressure in exfoliation glaucoma: long-term follow-up with self-tonometry
    Tarkkanen, Ahti
    Kivela, Tero
    ACTA OPHTHALMOLOGICA, 2018, 96 (08) : E1035 - E1037
  • [25] Precision and accuracy of proview tonometer: Clinical implications for self-tonometry
    Choudhari, NS
    Sekhar, GC
    Nutheti, R
    Thomas, R
    JOURNAL OF GLAUCOMA, 2005, 14 (06) : 515 - 515
  • [26] Determining Significant Elevation of Intraocular Pressure Using Self-tonometry
    Huang, Jessie
    Phu, Jack
    Kalloniatis, Michael
    Zangerl, Barbara
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (02) : 86 - 93
  • [27] SELF-TONOMETRY - TECHNICAL ASPECTS OF CALIBRATION AND CLINICAL-APPLICATION
    GROENHOFF, S
    DRAEGER, J
    DEUTSCH, C
    WIEZORREK, R
    HOCK, B
    INTERNATIONAL OPHTHALMOLOGY, 1992, 16 (4-5) : 299 - 303
  • [28] The Icare HOME (TA022) Study Performance of an Intraocular Pressure Measuring Device for Self-Tonometry by Glaucoma Patients
    Mudie, Lucy I.
    LaBarre, Sophie
    Varadaraj, Varshini
    Karakus, Sezen
    Onnela, Jouni
    Munoz, Beatriz
    Friedman, David S.
    OPHTHALMOLOGY, 2016, 123 (08) : 1675 - 1684
  • [29] Monitoring daily intraocular pressure fluctuations with self-tonometry in healthy subjects
    Querat, Laurence
    Chen, Enping
    ACTA OPHTHALMOLOGICA, 2017, 95 (05) : 525 - 529
  • [30] Pressure phosphene self-tonometry in a patient with Posner-Schlossman syndrome
    Leung, Dexter Y. L.
    Rao, Srinivas K.
    Lam, Dennis S. C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (06): : 513 - 515