Impact of self-tonometry on glaucoma treatment decision

被引:6
|
作者
Querat, Laurence [1 ,2 ]
Chen, Enping [1 ,2 ]
机构
[1] Karolinska Inst, Div Eye & Vis, Dept Clin Neurosci, Stockholm, Sweden
[2] St Erik Eye Hosp, Dept Anterior Segment Disorders Glaucoma Neurooph, Solna, Sweden
关键词
glaucoma treatment; Goldmann applanation tonometry; iCare (R) Home; intraocular pressure; self-tonometry; INDEPENDENT RISK-FACTOR; NORMAL OFFICE HOURS; INTRAOCULAR-PRESSURE; OCULAR HYPERTENSION; PROGRESSION; FLUCTUATIONS; MANAGEMENT; 24-HOUR;
D O I
10.1111/aos.15256
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to examine the impact of self-tonometry on clinicians' decision in glaucoma treatment. Materials and Methods: Medical records of 133 patients who had performed self-tonometry using iCare (R) Home between January and December 2019 were retrospectively reviewed. Inclusion criteria were as follows: age over 18 years, all types of glaucoma, as well as ocular hypertension and glaucoma suspect, compliance with tonometer manufacturer's recommendations and monitoring over at least 2 days. The data consisted of age, gender, diagnosis, visual field index, rate of progression and type of treatment pre- and post-intraocular pressure (IOP) phasing. The following TOP measurements were used to calculate the mean and maximum IOP, and range over each day and consecutive days: Goldmann applanation tonometry (GAT) measurements from referral and training visits and iCare (R) Home measurements made by the trainers and the patients themselves. A total of 90 patients were included. Results: Clinicians were satisfied with the actual treatment in 54.4% of the cases. There was a statistically significant difference between the clinicians' decision to maintain same treatment or to escalate therapy for all the mean and maximum IOPs measured on each single day and over a 2- or 3-day period (p <0.002). Conclusion: Our results suggest that the presence of high IOP values obtained with self-tonometry supports an intensification of glaucoma treatment. Self-tonometry provides clinicians with an important complement for clinical decision-making, and under- or over-treatment may be avoided for the benefit of patients.
引用
收藏
页码:E246 / E251
页数:6
相关论文
共 50 条
  • [1] Self-tonometry in glaucoma
    Tarkkanen, Ahti
    Ulfves, Kristian
    Ulfves, Tuulikki
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (11) : 1679 - 1681
  • [2] Self-tonometry in glaucoma
    Ahti Tarkkanen
    Kristian Ulfves
    Tuulikki Ulfves
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1679 - 1681
  • [3] Self-tonometry as a complement in the investigation of glaucoma patients
    Chen, Enping
    Querat, Laurence
    Akerstedt, Christina
    ACTA OPHTHALMOLOGICA, 2016, 94 (08) : 788 - 792
  • [4] Home Self-tonometry Trials Compared with Clinic Tonometry in Patients with Glaucoma
    McGlumphy, Elyse J.
    Mihailovic, Aleksandra
    Ramulu, Pradeep Y.
    Johnson, Thomas, V
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (06): : 569 - 580
  • [5] Pressure phosphene self-tonometry: A comparison with Goldmann tonometry in glaucoma patients
    Lam, DSC
    Leung, DYL
    Chiu, TYH
    Fan, DSP
    Cheung, EYY
    Wong, TY
    Lai, JSM
    Tham, CCY
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) : 3131 - 3136
  • [6] Self-tonometry with the Ocuton S: evaluation of accuracy in glaucoma patients
    Sacu, S
    Vass, C
    Schemper, M
    Rainer, G
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2004, 82 (04): : 405 - 409
  • [7] Self-tonometry with a Telemetric Intraocular Pressure Sensor in Patients With Glaucoma
    Koutsonas, A.
    Walter, P.
    Plange, N.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (06) : 743 - 748
  • [8] The evaluation of tonometry and self-tonometry with Ocuton tonometers
    Kothy, Peter
    Nagymihaly, Attila
    Hollo, Gabor
    MEDICAL SCIENCE MONITOR, 2003, 9 (01): : PI1 - PI4
  • [9] Self-tonometry in Glaucoma Management-Past, Present and Future
    Liang, Steve Y. -W.
    Lee, Graham A.
    Shields, David
    SURVEY OF OPHTHALMOLOGY, 2009, 54 (04) : 450 - 462
  • [10] Self-tonometry with the Ocuton S versus Goldmann tonometry
    Theofylaktopoulos, I
    Diestelhorst, M
    Krieglstein, GK
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (09) : 720 - 724