Effect of blade top clearance on semi-open fuel pump performance and leakage vortex

被引:1
|
作者
Liu, Xin [1 ]
Li, Yibin [1 ]
Wang, Bo
Zhang, Shengfu [1 ,2 ]
Jing, Weimin [1 ]
Li, Wanqi [1 ]
机构
[1] Lanzhou Univ Technol, Sch Energy & Power Engn, Lanzhou 730050, Peoples R China
[2] Lanzhou Wanli Aero Electromech Ltd Corp Co Ltd, Lanzhou 730070, Peoples R China
关键词
Fuel pumps; Blade top clearances; Leakage vortex; Vorticity transport equation; Entropy generation; FLOW;
D O I
10.1007/s40430-023-04259-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In order to reveal the fuel pump performance and leakage vortex characteristics under different blade top clearances, three schemes with blade top clearances of 0.1 mm, 0.2 mm, and 0.3 mm are chosen in this paper to reveal the fuel pump performance and leakage vortex characteristics under various blade top clearances. The SST k-omega turbulence model is then used to numerically simulate the semi-open fuel pump and analyze the fuel pump external characteristics, leakage vortex structure, motion trajectory, formation mechanism, blade pressure loading, and entropy generation rate in the impeller. The results demonstrate that as the blade top clearance increases, the hydraulic performance of the fuel pump decreases and the area of the separated vortex area in the blade top clearance area increases; at phi = 0.3 mm, the fuel pump's efficiency is about 6% less efficient than at phi = 0.1 mm; under all three blade top clearances, there are two leakage vortices, TLV1 and TLV2, with TLV1 having the most influence on the flow pattern in the main flow area. the pressure coefficient difference Delta C-p is the greatest near the leading edge of the blade, leading to the formation of TLV here; from the blade inlet to outlet, TLV motion trajectory gradually away from the blade suction surface, and as the blade top clearance becomes larger, the motion trajectory deviates from the blade suction surface more, which is mainly caused by the Koch force term in the vortex transport equation; entropy generation rate and TLV distribution location are basically the same, mainly distributed in the blade suction surface side. The closer the blade top clearance area, the higher the entropy generation rate; the larger the blade top clearance, the larger the distribution area of high entropy generation rate, the stronger the mechanical energy dissipation effect in the fuel pump.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Optimization design of semi-open impeller based on thrombogenicity in a blood pump
    Liu, Xuemin
    Shao, Jiejie
    Wang, Peng
    Zhao, Honghua
    Liu, Luning
    Han, Qing
    ARTIFICIAL ORGANS, 2024, 48 (09) : 1060 - 1069
  • [32] Improvement of washout flow in a centrifugal blood pump by a semi-open impeller
    Tsukiya, T.
    Taenaka, Y.
    Tatsumi, E.
    Takano, H.
    ASAIO Journal, 2000, 46 (02)
  • [33] Improvement of washout flow in a centrifugal blood pump by a semi-open impeller
    Tsukiya, T
    Taenaka, Y
    Tatsumi, E
    Takano, H
    ASAIO JOURNAL, 2002, 48 (01) : 76 - 82
  • [34] Study on Internal Flow and External Performance of a Semi-open Impeller Centrifugal Pump with Different Tip Clearances
    Jia, Xiao-Qi
    Cui, Bao-Ling
    Zhang, Yu-Liang
    Zhu, Zu-Chao
    INTERNATIONAL JOURNAL OF TURBO & JET-ENGINES, 2015, 32 (01) : 1 - 12
  • [35] Effects of tip clearance and impeller geometry on the performance of semi-open ceramic centrifugal fan impellers at elevated temperatures
    Engin, Tahsin
    Gur, Mesut
    Scholz, Reinhard
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2006, 30 (06) : 565 - 577
  • [36] Effect of a bearing gap on hemolytic property in a hydrodynamically levitated centrifugal blood pump with a semi-open impeller
    Kosaka, Ryo
    Nishida, Masahiro
    Maruyama, Osamu
    Yambe, Tomoyuki
    Imachi, Kou
    Yamane, Takashi
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2013, 23 (1-2) : 37 - 47
  • [37] GEROTOR FUEL PUMP PERFORMANCE AND LEAKAGE STUDY
    Alberto Ruvalcaba, Mario
    Hu, Xiao
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 6, PTS A AND B, 2012, : 807 - 815
  • [38] Improvement of hemolysis in a centrifugal blood pump with hydrodynamic bearings and semi-open impeller
    Kosaka, Ryo
    Yamane, Takashi
    Maruyama, Osamu
    Nishida, Masahiro
    Yada, Toru
    Saito, Sakae
    Hirai, Shusaku
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3982 - 3985
  • [39] INTERNAL FLOW CONDITION OF FLUID FOOD PUMP USING SEMI-OPEN IMPELLER
    Shigemitsu, Toru
    Shinohara, Hirotaka
    Matsubara, Takumi
    Fukutomi, Junichiro
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2015, VOL 1A, SYMPOSIA, PT 2, 2016,
  • [40] Effect of thermal deformation on leakage clearance of claw hydrogen circulating pump for fuel cell system
    Dong, Kairui
    Liu, Guangbin
    Yang, Qichao
    Zhao, Yuanyang
    Li, Liansheng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (66) : 28655 - 28669