Quantifying cerebral microbleeds using quantitative susceptibility mapping from magnetization-prepared rapid gradient-echo

被引:1
|
作者
Naji, Nashwan [1 ]
Gee, Myrlene [2 ]
Jickling, Glen C. [2 ]
Emery, Derek J. [3 ]
Saad, Feryal [4 ]
Mccreary, Cheryl R. [4 ,5 ]
Smith, Eric E. [4 ]
Camicioli, Richard [2 ]
Wilman, Alan H. [1 ,3 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB T6G 1H9, Canada
[2] Univ Alberta, Div Neurol, Edmonton, AB, Canada
[3] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
[4] Univ Calgary, Hotchkiss Brain Inst, Radiol & Clin Neurosci, Calgary, AB, Canada
[5] Foothills Med Ctr, Seaman Family MR Res Ctr, Calgary, AB, Canada
基金
加拿大健康研究院;
关键词
3; T; microbleed; MPRAGE; QSM; TISSUE; RECONSTRUCTION; DISEASE; FIELD; T-1;
D O I
10.1002/nbm.5139
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) is commonly included in brain studies for structural imaging using magnitude images; however, its phase images can provide an opportunity to assess microbleed burden using quantitative susceptibility mapping (QSM). This potential application for MPRAGE-based QSM was evaluated using in vivo and simulated measurements. Possible factors affecting image quality were also explored. Detection sensitivity was evaluated against standard multiecho gradient echo (MEGE) QSM using 3-T in vivo data of 15 subjects with a combined total of 108 confirmed microbleeds. The two methods were compared based on the microbleed size and susceptibility measurements. In addition, simulations explored the detection sensitivity of MPRAGE-QSM at different representative magnetic field strengths and echo times using microbleeds of different size, susceptibility, and location. Results showed that in vivo microbleeds appeared to be smaller (x 0.54) and of higher mean susceptibility (x 1.9) on MPRAGE-QSM than on MEGE-QSM, but total susceptibility estimates were in closer agreement (slope: 0.97, r2: 0.94), and detection sensitivity was comparable. In simulations, QSM at 1.5 T had a low contrast-to-noise ratio that obscured the detection of many microbleeds. Signal-to-noise ratio (SNR) levels at 3 T and above resulted in better contrast and increased detection. The detection rates for microbleeds of minimum one-voxel diameter and 0.4-ppm susceptibility were 0.55, 0.80, and 0.88 at SNR levels of 1.5, 3, and 7 T, respectively. Size and total susceptibility estimates were more consistent than mean susceptibility estimates, which showed size-dependent underestimation. MPRAGE-QSM provides an opportunity to detect and quantify the size and susceptibility of microbleeds of at least one-voxel diameter at B0 of 3 T or higher with no additional time cost, when standard T2*-weighted images are not available or have inadequate spatial resolution. The total susceptibility measure is more robust against sequence variations and might allow combining data from different protocols. Quantifying microbleeds' susceptibility and size using QSM derived from MPRAGE was evaluated using in vivo and simulated measurements, in comparison with standard multiecho QSM. Results showed that the detection sensitivity of MPRAGE-QSM was comparable with standard QSM. MPRAGE-QSM provides an opportunity to detect and quantify the size and susceptibility of microbleeds of at least one-voxel diameter at B0 >= 3 T with no additional time cost, when standard T2*w images are not available or have inadequate spatial resolution. image
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Detection of colorectal liver metastases with magnetization-prepared rapid acquisition gradient echo: Thinner slices, better performance?
    Pijl, ME
    Hoekstra, J
    Wasser, MN
    RADIOLOGY, 2002, 225 : 299 - 299
  • [32] IMPROVED EFFICIENCY IN 2DFT MAGNETIZATION-PREPARED RAPID GRADIENT ECHO IMAGING - APPLICATION TO ABDOMINAL IMAGING
    BAMPTON, AEH
    RIEDERER, SJ
    MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (01) : 195 - 203
  • [33] Phase-corrected bipolar gradients in multi-echo gradient-echo sequences for quantitative susceptibility mapping
    Jianqi Li
    Shixin Chang
    Tian Liu
    Hongwei Jiang
    Fang Dong
    Mengchao Pei
    Qianfeng Wang
    Yi Wang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 347 - 355
  • [34] Associations of High Intensities on Magnetization-Prepared Rapid Acquisition with Gradient Echo with Aortic Complicated Lesions in Ischemic Stroke Patients
    Yamaguchi, Yoshitaka
    Tanaka, Tomotaka
    Morita, Yoshiaki
    Yoshimura, Sohei
    Koga, Masatoshi
    Ihara, Masafumi
    Toyoda, Kazunori
    CEREBROVASCULAR DISEASES, 2019, 47 (1-2) : 15 - 23
  • [35] Free-breathing myocardial T1 mapping using magnetization-prepared slice interleaved spoiled gradient echo imaging
    Sébastien Roujol
    Jihye Jang
    Tamer A Basha
    Sebastian Weingartner
    Sophie Berg
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [36] Gadolinium-enhanced breath-hold three-dimensional MR angiography of the portal vein: Value of the magnetization-prepared rapid acquisition gradient-echo sequence
    Yamashita, Y
    Mitsuzaki, K
    Miyazaki, T
    Namimoto, T
    Sumi, S
    Urata, J
    Abe, Y
    Ogata, I
    Takahashi, M
    RADIOLOGY, 1996, 201 (01) : 283 - 288
  • [37] MAGNETIZATION PREPARED RAPID GRADIENT-ECHO (MP-RAGE) MR IMAGING OF THE LIVER - COMPARISON WITH SPIN-ECHO IMAGING
    DELANGE, EE
    MUGLER, JP
    BERTOLINA, JA
    GAY, SB
    JANUS, CL
    BROOKEMAN, JR
    MAGNETIC RESONANCE IMAGING, 1991, 9 (04) : 469 - 476
  • [38] Cerebral artery segmentation based on magnetization-prepared two rapid acquisition gradient echo multi-contrast images in 7 Tesla magnetic resonance imaging
    Choi, Uk-Su
    Kawaguchi, Hirokazu
    Kida, Ikuhiro
    NEUROIMAGE, 2020, 222
  • [39] Non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE) in the preoperative evaluation of living liver donor candidates: Comparison with conventional computed tomography venography
    Yamashita, Rikiya
    Isoda, Hiroyoshi
    Arizono, Shigeki
    Ono, Ayako
    Onishi, Natsuko
    Furuta, Akihiro
    Togashi, Kaori
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 90 : 89 - 96
  • [40] Gadolinium-Enhanced Three-Dimensional Magnetization-Prepared Rapid Gradient-Echo (3D MP-RAGE) Imaging is Superior to Spin-Echo Imaging in Delineating Brain Metastases
    Takeda, T.
    Takeda, A.
    Nagaoka, T.
    Kunieda, E.
    Takemasa, K.
    Watanabe, M.
    Hatou, T.
    Oguro, S.
    Katayama, M.
    ACTA RADIOLOGICA, 2008, 49 (10) : 1167 - 1173