A novel optimization strategy for line loss reduction in distribution networks with large penetration of distributed generation

被引:9
|
作者
Fu, Jiaqing [1 ]
Han, Yang [1 ]
Li, Wenhao [1 ]
Feng, Yingjun [1 ]
Zalhaf, Amr S. [1 ,2 ]
Zhou, Siyu [1 ]
Yang, Ping [1 ]
Wang, Congling [1 ]
机构
[1] Univ Elect Sci & Technol China UESTC, Sch Mech & Elect Engn, Chengdu 611731, Peoples R China
[2] Tanta Univ, Fac Engn, Elect Power & Machines Engn Dept, Tanta 31511, Egypt
关键词
Line loss minimization; Power electronic distribution network; Harmonic constraints; Distributed generation alposition; DG UNITS; OPTIMAL PLACEMENT; MULTIOBJECTIVE OPTIMIZATION; DISTRIBUTION-SYSTEMS; ALGORITHM; LOCATION; POWER; MICROGRIDS; CAPACITY;
D O I
10.1016/j.ijepes.2023.109112
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the large penetration of power electronic devices in distribution networks, power quality problems such as line loss and harmonics have become the main factors affecting the access of distributed generation (DG). At present, the research on DG integration, such as the optimization of the DG capacity using particle swarm optimization algorithm and ant colony algorithm, is mainly focused on the traditional distribution network. In contrast, the research on the power electronic distribution networks, which include a large number of harmonic sources, is not sufficient. This paper presents a novel optimization method for connecting DG to power electronic distribution network to reduce line loss. Firstly, based on the frequency domain model of the distribution network, this paper establishes the harmonic model of distribution network components, including generators, transformers, lines, harmonic sources and non-harmonic sources. Then the location and capacity of DG are optimized using genetic algorithm with network loss reduction as a target and voltage and harmonic as con-straints. Finally, the power electronic distribution network is modelled based on the IEEE 34 -node standard model. The obtained results confirmed that the optimization model with harmonic constraints can effectively reduce the line loss by 108.26 kW and the line loss rate by 4.67 % using single DG. Also, when using the double DG, the line loss and the line loss rate are decreased by 118.53 kW and 5.14 %, respectively. In addition, the optimization effect of dual DG is better than that of single DG without considering the cost.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] An intelligent strategy for faults location in distribution networks with distributed generation
    Perez, Ramon
    Vasquez, Carmen
    Viloria, Amelec
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2019, 36 (02) : 1627 - 1637
  • [22] A Loss Reduction Optimization Method for Distribution Network Based on Combined Power Loss Reduction Strategy
    Xie, Jihua
    Chen, Chang
    Long, Huan
    COMPLEXITY, 2021, 2021
  • [23] Evaluation of Distributed Generation Impacts on Distribution Networks under Different Penetration Scenarios
    Quiroga, G. A.
    Kagan, H.
    Amasifen, J. C. C.
    Almeida, C. F. M.
    Vicentini, E.
    2015 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES LATIN AMERICA (ISGT LATAM), 2015, : 136 - 141
  • [24] Worst Case Scenario for Large Distribution Networks with Distributed Generation
    Mahmud, M. A.
    Hossain, M. J.
    Pota, H. R.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [25] Impact of High Penetration of Photovoltaic Distributed Generation on the Protection Coordination in Distribution Networks
    Alvarez-Macias, Hector A.
    Pena-Gallardo, Rafael
    Soubervielle-Montalvo, Carlos
    de Leon-Mendoza, Edgar D.
    Pecina-Sanchez, Jose A.
    2022 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2022,
  • [26] A multi-objective approach to maximize the penetration of distributed generation in distribution networks
    Celli, G.
    Ghiani, E.
    Mocci, S.
    Pilo, F.
    2006 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, VOLS 1 AND 2, 2006, : 530 - 535
  • [27] Maximizing Delivery Capability of Unbalanced Distribution Networks for High Penetration of Distributed Generation
    Jian, Liu
    Chiang, Hsiao-Dong
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [28] Calculation Method of Line Loss in Distribution Network Considering Distributed Generation
    Ru, XuLi
    Chen, Fang
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 7391 - 7397
  • [29] Power Loss Reduction in a Radial Distribution Network Using Distributed Generation
    Alam, Afroz
    Zaid, Mohammad
    Gupta, Abhishek
    Bindal, Parth
    Siddiqui, Aiman
    2018 INTERNATIONAL CONFERENCE ON COMPUTING, POWER AND COMMUNICATION TECHNOLOGIES (GUCON), 2018, : 1142 - 1145
  • [30] Energy loss reduction by optimal distributed generation allocation in distribution systems
    Haghighat, Hossein
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (09): : 1673 - 1684