Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience

被引:11
|
作者
Stein, Thomas [1 ]
Rau, Alexander [1 ]
Russe, Maximilian Frederik [1 ]
Arnold, Philipp [1 ]
Faby, Sebastian [2 ]
Ulzheimer, Stefan [2 ]
Weis, Meike [3 ]
Froelich, Matthias F. [3 ]
Overhoff, Daniel [3 ]
Horger, Marius [4 ]
Hagen, Florian [4 ]
Bongers, Malte [4 ]
Nikolaou, Konstantin [4 ]
Schoenberg, Stefan O. [3 ]
Bamberg, Fabian [1 ]
Weiss, Jakob [1 ]
机构
[1] Univ Freiburg, Dept Diagnost & Intervent Radiol, Ctr Med, Freiburg, Germany
[2] Siemens Healthcare GmbH, Computed Tomog, Forchheim, Germany
[3] Univ Med Ctr Mannheim, Dept Radiol & Nucl Med, Mannheim, Germany
[4] Univ Hosp Tubingen, Dept Radiol, Tubingen, Germany
关键词
Photon Counting; Computed Tomography; Diagnostic Imaging; Spectral Computed Tomography; Photon-Counting Detector; Energy-Integrating Detectors; DUAL-ENERGY CT; IMAGE NOISE; SPIRAL CT; SYSTEM; PERFORMANCE; ACCURACY;
D O I
10.1055/a-2018-3396
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change todays workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. Method The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms "Photon-Counting CT", "Photon-Counting detector", "spectral CT", "Computed Tomography" as well as on the authors' experience. Results The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. Conclusion For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases.
引用
收藏
页码:691 / 698
页数:8
相关论文
共 50 条
  • [41] Photon counting computed tomography: Concept and initial results
    Shikhaliev, PM
    Xu, T
    Molloi, S
    MEDICAL PHYSICS, 2005, 32 (02) : 427 - 436
  • [42] Initial Clinical Images From a Second-Generation Prototype Silicon-Based Photon-Counting Computed Tomography System
    Almqvist, Hakan
    Crotty, Dominic
    Nyren, Sven
    Yu, Jimmy
    Arnberg-Sandor, Fabian
    Brismar, Torkel
    Tovatt, Cedric
    Linder, Hugo
    Dagotto, Jose
    Fredenberg, Erik
    Tamm, Moa Yveborg
    Deak, Paul
    Fanariotis, Michail
    Bujila, Robert
    Holmin, Staffan
    ACADEMIC RADIOLOGY, 2024, 31 (02) : 572 - 581
  • [43] Clinical Impact and Diagnostic Performance of Photon-Counting Detector Computed Tomography in Coronary Artery Disease
    Sakai, Koshiro
    Shin, Doosup
    Singh, Mandeep
    Malik, Sarah
    Dakroub, Ali
    Sami, Zainab
    Weber, Jonathan
    Cao, Jane
    Parikh, Roosha
    Sosa, Fernando
    Cohen, David
    Moses, Jeffrey
    Shlofmitz, Richard
    Collet, Carlos
    Shlofmitz, Evan
    Jeremias, Allen
    Ali, Ziad
    Khalique, Omar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B170 - B171
  • [44] Diagnostic Performance and Clinical Impact of Photon-Counting Detector Computed Tomography in Coronary Artery Disease
    Sakai, Koshiro
    Shin, Doosup
    Singh, Mandeep
    Malik, Sarah
    Dakroub, Ali
    Sami, Zainab
    Weber, Jonathan
    Cao, J. Jane
    Parikh, Roosha
    Chen, Lu
    Sosa, Fernando
    Cohen, David J.
    Moses, Jeffrey W.
    Shlofmitz, Richard A.
    Collet, Carlos
    Shlofmitz, Evan
    Jeremias, Allen
    Khalique, Omar K.
    Ali, Ziad A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2025, 85 (04) : 339 - 348
  • [45] No gadolinium K-edge detected on the first clinical photon-counting computed tomography scanner
    Baubeta, Erik
    Laurin Gadsboll, Eva
    Will, Leon
    Holmquist, Fredrik
    Aurumskjold, Marie-Louise
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (04):
  • [46] Clinical Utility of Multi-Energy Spectral Photon-Counting Computed Tomography in Crystal Arthritis
    Stamp, Lisa K.
    Anderson, Nigel G.
    Becce, Fabio
    Rajeswari, Maya
    Polson, Matthew
    Guyen, Olivier
    Viry, Anais
    Choi, Chloe
    Kirkbride, Tracy E.
    Raja, Aamir Y.
    ARTHRITIS & RHEUMATOLOGY, 2019, 71 (07) : 1158 - 1162
  • [47] Exploration of the pulse pileup effects in a clinical CdTe-based photon-counting computed tomography
    Bhattarai, Mridul
    Bache, Steve
    Abadi, Ehsan
    Samei, Ehsan
    MEDICAL PHYSICS, 2023, 50 (11) : 6693 - 6703
  • [48] Validation of Photon-counting Computed Tomography Image Data for Radiation Therapy
    Richter, Anne
    Razinskas, Gary
    Paulus, Patrick
    Weick, Stefan
    Lutyj, Paul
    Kraft, Johannes
    Huflage, Henner
    Grunz, Jan-Peter
    Bley, Thorsten
    Flentje, Michael
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 : S141 - S141
  • [49] Accuracy of photon-counting computed tomography for the measurement of bone quality in the knee
    Azari, Fahimeh
    Uniyal, Piyush
    Soete, Jeroen
    Coudyzer, Walter
    Wyers, Caroline E.
    Quintiens, Jilmen
    van den Bergh, Joop P.
    van Lenthe, Harry
    BONE, 2024, 181
  • [50] Toward molecular imaging using spectral photon-counting computed tomography?
    Sawall, Stefan
    Amato, Carlo
    Klein, Laura
    Wehrse, Eckhard
    Maier, Joscha
    Kachelriess, Marc
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2021, 63 : 163 - 170