Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study

被引:13
|
作者
Kernen, Florian [1 ]
Braendle, Dominik [1 ]
Wagendorf, Oliver [2 ,3 ,4 ,5 ]
Recca, Mario [6 ]
Mehrhof, Juergen [7 ]
Vach, Kirstin [8 ]
Nahles, Susanne [6 ]
Nelson, Katja [1 ]
Fluegge, Tabea [6 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Oral & Maxillofacial Surg Translat Implantol, Freiburg, Germany
[2] Dept Oral & Maxillofacial Surg, Berlin, Germany
[3] Free Univ Berlin, Berlin, Germany
[4] Humboldt Univ, Berlin, Germany
[5] Charite Univ Med Berlin, Berlin Inst Hlth, Berlin, Germany
[6] Univ Freiburg, Fac Med, Med Ctr, Dept Prosthet Dent, Freiburg, Germany
[7] Mehrhof Implant Technol GmbH, Berlin, Germany
[8] Univ Freiburg, Fac Med, Med Ctr, Inst Med Biometry & Stat, Freiburg, Germany
关键词
accuracy; dental implant; dental Impression; digital Dentistry; digital impression; intraoral scanner; optical Imaging; scan body; SURFACE RECONSTRUCTION; IMPRESSIONS;
D O I
10.1111/clr.14107
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Intraoral scans of multiple implants in the edentulous arch are challenged by the absence of a distinct surface morphology between scan bodies. A scan aid was applied in such situation and evaluated for intraoral scanning accuracy in vivo. Materials and Methods: 87 implants in 22 patients were scanned with scan aid (SA) and without scan aid (NO) using two different intraoral scanners (CS3600 [CS] and TRIOS3 [TR]). Master casts were digitized by a laboratory scanner. Virtual models were superimposed using an inspection software and Linear deviation and precision were measured. Statistical analysis was performed using linear mixed models (alpha =.05). Results: Total mean linear deviation within the CS group was 189 mu m without scan aid and 135 mu m when using the scan aid. The TR group's total mean deviation was 165 mu m with and without a scan aid. Significant improvement with scan aid was observed for the CS group (p =.001), and no difference was found in the TR group. 96% of scan bodies were successfully scanned in the TR-SA group compared to 86% for the TR-NO group, 83% for the CS-SA, and 70% for the CS-NO group, respectively. Conclusions: The evaluated scan aid improved linear deviation compared to unsplinted scans for the CS group but not for the TR group. These differences could originate from different scanning technologies used, active triangulation (CS) and confocal microscopy (TR). The scan aid improved the ability to recognize scan bodies successfully with both systems, which could have a favorable clinical impact overall.
引用
收藏
页码:793 / 801
页数:9
相关论文
共 50 条
  • [21] Influence of rescanning mesh holes on the accuracy of an intraoral scanner: An in vivo study
    Revilla-Leon, Marta
    Quesada-Olmo, Nieves
    Gomez-Polo, Miguel
    Sicilia, Elena
    Farjas-Abadia, Mercedes
    Kois, John C.
    JOURNAL OF DENTISTRY, 2021, 115
  • [22] Factors that influence the accuracy of intraoral scanning of total edentulous arches rehabilitated with multiple implants: A systematic review
    Pereira, Ana Larisse Carneiro
    Curinga, Miria Rafaelli Souza
    Segundo, Henrique Vieira Melo
    Porto Carreiro, Adriana da Fonte
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06): : 855 - 862
  • [23] Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner
    Mueller, Philipp
    Ender, Andreas
    Joda, Tim
    Katsoulis, Joannis
    QUINTESSENCE INTERNATIONAL, 2016, 47 (04): : 343 - 349
  • [24] Influence of scan technology on the accuracy and speed of intraoral scanning systems for the edentulous maxilla: An in vitro study
    Osman, Reham Bassuni
    Alharbi, Nawal Murshed
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 821 - 828
  • [25] Face oriented digital workflow for transferring intraoral and extraoral data of edentulous arch rehabilitated with multiple implants: A clinical technique
    Nuytens, Philippe
    Li, Junying
    Lepidi, Luca
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 655 - 661
  • [26] Superimposition of intraoral scans of an edentulous arch with implants and implant-supported provisional restoration, implementing a novel implant prosthetic scan body
    Ntovas, Panagiotis
    Spanopoulou, Maria
    Martin, William
    Sykaras, Nikitas
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (03) : 475 - 480
  • [27] Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry
    Cheng, Jing
    Zhang, Haidong
    Liu, Hailin
    Li, Junying
    Wang, Hom-Lay
    Tao, Xian
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) : 560 - 572
  • [28] Impact of Different Scan Bodies and Scan Strategies on the Accuracy of Digital Implant Impressions Assessed with an Intraoral Scanner: An In Vitro Study
    Motel, Constantin
    Kirchner, Elena
    Adler, Werner
    Wichmann, Manfred
    Matta, Ragai Edward
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (04): : 309 - 314
  • [29] Accuracy of Photogrammetry, Intraoral Scanning, and Conventional Impression for Multiple Implants: An In Vitro Study
    Lyu, Mingyue
    Li, Yizhou
    Xu, Dingyi
    Xing, Qi
    Zhang, Shiwen
    Yuan, Quan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2025, 27 (01)
  • [30] Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan
    Deferm, Julie Tilly
    Baan, Frank
    Nijsink, Johan
    Verhamme, Luc
    Maal, Thomas
    Meijer, Gert
    IMAGING SCIENCE IN DENTISTRY, 2023, 53 (01) : 21 - 26