An acoustic sensor based on balloon-shaped microfiber Mach-Zehnder interferometer

被引:7
|
作者
Zhu, Xiaojun [1 ]
Sun, Ang [1 ]
Pan, Yongquan [1 ]
Zhuang, Haoran [1 ]
Liu, Wen [1 ]
Cao, Juan [1 ]
Zhang, Guoan [1 ]
Yang, Yongjie [1 ]
Liang, Zhipeng [1 ]
Shi, Yuechun [2 ]
Wu, Wuming [3 ]
机构
[1] Nantong Univ, Sch Informat Sci & Technol, Nantong 226019, Jiangsu, Peoples R China
[2] Nanjing Univ, Key Lab Intelligent Opt Sensing & Manipulat, Minist Educ, Nanjing 210093, Peoples R China
[3] Hunan Univ, Phys & Microelect, Changsha 410082, Hunan, Peoples R China
来源
关键词
Polarization-maintaining fiber; Mach-Zehnder interferometer; Balloon-shaped loop structure; Acoustic sensor; Micro-fiber;
D O I
10.1016/j.optlastec.2023.109447
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An acoustic sensor based on balloon-shaped microfiber Mach-Zehnder Interferometer (BSMZI) is proposed and demonstrated. The BSMZI is constructed by bending a tapered polarization-maintaining fiber (PMF), which has the interference phenomenon due to the phase difference between the fundamental mode and cladding modes of the balloon-shaped loop structure. When placing the sensor in front of a loudspeaker and using a fiber Bragg grating (FBG) as the signal reflector, the transmission spectra of the sensor can be changed with the acoustic signals correspondingly. Furthermore, by changing the bending radius of the BSMZI, the maximum sensitivity of the sensor is 115 mV/Pa, and the minimum detection pressure of the noise limit is 2.1 mPa/root Hz when the acoustic frequency range change from 100 Hz to 2000 Hz. The experimental results show that the sensor has a good ability in acoustic detection and has potential application in the fields of nuclear magnetic medical treatment and security interception.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Locating acoustic emission with an amplitude-multiplexed acoustic sensor array based on a modified Mach-Zehnder interferometer
    Gong, JM
    MacAlpine, JMK
    Jin, W
    Liao, YB
    APPLIED OPTICS, 2001, 40 (34) : 6199 - 6202
  • [42] Ultrasensitive Strain Sensor Based on Mach-Zehnder Interferometer With Bent Structures
    Wang, Senyu
    Ma, Yiwei
    Chen, Wenhuan
    Wang, Shengjia
    Yi, Yang
    Li, Xiaoyang
    Lu, Chupeng
    Zhang, Shuo
    Geng, Tao
    Sun, Weimin
    Yuan, Libo
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (21) : 6958 - 6967
  • [43] High sensitive pressure sensor based on plasmonic Mach-Zehnder interferometer
    Kumar, Manish
    Raghuwanshi, Sanjeev Kumar
    Pareek, Prakash
    PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES XXV, 2017, 10098
  • [44] Highly sensitive curvature sensor based on an asymmetrical Mach-Zehnder interferometer
    Xia, Feng
    Zhao, Yong
    Hu, Hai-Feng
    Chen, Mao-Qing
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2017, 45 (06) : 605 - 617
  • [45] DESIGN AND SIMULATION OF A INTEGRATED MACH-ZEHNDER INTERFEROMETER SENSOR
    Ionita, Mihaela Roxana
    Kusko, Mihai
    2010 INTERNATIONAL SEMICONDUCTOR CONFERENCE (CAS), VOLS 1 AND 2, 2010, : 529 - 532
  • [46] Micro-optic temperature sensor based on a Mach-Zehnder interferometer
    Park, Sung Jo
    Lee, Jong Hoon
    Kwon, Hyung Woo
    Kim, Kyu-Jin
    Jang, Su-Won
    Kang, Shin-Won
    Song, Jae-Won
    Kim, Hyun Deok
    2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 417 - +
  • [47] Simulation and optimization of sensor based on Mach-Zehnder interferometer with reference waveguide
    Kusko, M. (mihai.kusko@imt.ro), 1600, National Institute of Optoelectronics (07): : 11 - 12
  • [48] Optical fiber sensor based on a radio frequency Mach-Zehnder interferometer
    Wei, Tao
    Huang, Jie
    Lan, Xinwei
    Han, Qun
    Xiao, Hai
    OPTICS LETTERS, 2012, 37 (04) : 647 - 649
  • [49] Highly Sensitive Temperature Fiber Sensor Based on Mach-Zehnder Interferometer
    Hsu, Jui-Ming
    Chen, Jian-Zhi
    Zheng, Wen-Hao
    FIBER AND INTEGRATED OPTICS, 2016, 35 (5-6) : 230 - 238
  • [50] Integrated optical dual Mach-Zehnder interferometer sensor
    Hua, P
    Kawaguchi, K
    Wilkinson, JS
    CLEO(R)/PACIFIC RIM 2001, VOL I, TECHNICAL DIGEST, 2001, : 156 - 157