A Modified Hand-Held Force Meter to Measure Yarn Tension in the Ring Spinning Process

被引:0
|
作者
Ling, Yali [1 ]
Chen, Mingtai [2 ]
Liu, Yang [1 ,3 ]
Yin, Rong [1 ]
机构
[1] North Carolina State Univ, Wilson Coll Text, Text Engn Chem & Sci, Raleigh, NC 27695 USA
[2] North Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC 27695 USA
[3] Xiayi Lixing Res Inst Text & Apparel, Shangqiu 476400, Henan, Peoples R China
关键词
Yarn tension; Yarn twist; Tension meter; Mathematical modeling; Ring spinning;
D O I
10.1007/s12221-023-00271-z
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
Yarn tension measurement and control are crucial in ensuring high-quality ring yarn production. Currently, the predominant testing method is to apply a three-roller tension meter to measure the yarn tension between the front rollers and yarn guide. However, the measurement hinders the twist propagation probably causing yarn breakage during the spinning process. In this study, a modified hand-held force meter was proposed to measure the yarn tension with reduced wrap angle. The yarn tension meter was calibrated, and the results showed that the errors between actual yarn tension and theoretical tension are less than 7%. The tension meter was then used in the real-spinning process, and it was found that the spinning stability was not affected by the tension sensor. Additionally, a theoretical model was used to analyze the effect of the wrap angle on the yarn tension and twist distribution. The results showed that due to the reduced wrap angle, yarn tension and twist distribution were not significantly affected. The most significant advantage of this tension meter is its minimal impact on the spinning process and yarn performance, while being a cost-effective and simple solution for measuring yarn tension.
引用
收藏
页码:2967 / 2975
页数:9
相关论文
共 50 条
  • [41] Evaluation of a hand-held electrical conductivity meter for detection of subclinical mastitis in cattle
    Musser, JMB
    Anderson, KL
    Caballero, M
    Amaya, D
    Maroto-Puga, J
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1998, 59 (09) : 1087 - 1091
  • [42] AN EVALUATION OF 14 HAND-HELD BATTERY-OPERATED SPINNING DISK SPRAYERS
    ARNOLD, AC
    TROPICAL PEST MANAGEMENT, 1983, 29 (02): : 105 - 121
  • [43] A new hand-held indirect calorimeter to measure postprandial energy expenditure
    St-Onge, MP
    Rubiano, F
    Jones, A
    Heymsfield, SB
    OBESITY RESEARCH, 2004, 12 (04): : 704 - 709
  • [44] Grip force control during gait initiation with a hand-held object
    Gudrun Diermayr
    Priska Gysin
    Chris J. Hass
    Andrew M. Gordon
    Experimental Brain Research, 2008, 190 : 337 - 345
  • [45] Effects of surface texture and grip force on the discrimination of hand-held loads
    Flanagan, JR
    Wing, AM
    PERCEPTION & PSYCHOPHYSICS, 1997, 59 (01): : 111 - 118
  • [46] Effects of surface texture and grip force on the discrimination of hand-held loads
    J. Randall Flanagan
    Alan M. Wing
    Perception & Psychophysics, 1997, 59 : 111 - 118
  • [47] Grip force control during gait initiation with a hand-held object
    Diermayr, Gudrun
    Gysin, Priska
    Hass, Chris J.
    Gordon, Andrew M.
    EXPERIMENTAL BRAIN RESEARCH, 2008, 190 (03) : 337 - 345
  • [48] Tension of rotor-spun composite yarn during spinning process
    Yang, Rui-Hua
    Wu, Yue
    Wang, Shan-Yuan
    INTERNATIONAL JOURNAL OF NONLINEAR SCIENCES AND NUMERICAL SIMULATION, 2009, 10 (07) : 903 - 906
  • [49] Validation of a portable hand-held whole-blood ketone meter for use in cats
    Weingart, Christiane
    Lotz, Fabian
    Kohn, Barbara
    VETERINARY CLINICAL PATHOLOGY, 2012, 41 (01) : 114 - 118
  • [50] Use of a hand-held meter for the measurement of blood beta-hydroxybutyrate in dogs and cats
    Hoenig, Margarethe
    Dorfman, Mark
    Koenig, Amie
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2008, 18 (01) : 86 - 87