Effect of chevron angle on the thermofluids performance of shell-and-plate heat exchangers - A numerical approach

被引:2
|
作者
Zhao, Yi [1 ]
Liu, Hai-yong [1 ]
Zhang, Li [1 ]
Wang, Chi-Chuan [2 ]
机构
[1] Northwestern Polytech Univ, Sch Power & Energy, Xian 710072, Shaanxi, Peoples R China
[2] Natl Yang Ming Chiao Tung Univ, Dept Mech Engn, Hsinchu 300, Taiwan
关键词
Shell-and-plate heat exchanger; Chevron angle; Nusselt number; Friction factor; Mal; -distribution; FLOW;
D O I
10.1016/j.applthermaleng.2023.122061
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study conducts a detailed numerical study upon the effect of chevron angle on the thermofluids characteristics of shell-and-plate heat exchangers. The plate diameter is 215 mm and the chevron angles (beta) are 30 degrees, 45 degrees, 60 degrees, and 75 degrees. Simulations are performed with Reynolds number ranging from 200 to 1000. The heat transfer and frictional performance are termed as Nusselt number (Nu) and friction factor (f), and results for both shell and plate side are reported. The Nusselt number and friction factor in the shell side are increased with the rise of chevron angle. For the same inlet flowrate, the pressure profile in the shell side changes significantly with the chevron angle, from uniform (beta = 30 degrees) to concave (beta = 45 degrees similar to 60 degrees) and finally to slightly convex (beta = 75 degrees) while the pressure profile in the plate side is always convex. In the plate side, the Nusselt number increases with the rise of chevron angle. But the lowest friction factor occurs when beta = 45 degrees due to a better flow distribution. The heat transfer performance in the shell side is superior to the plate side due to the presence of the inlet/outlet manifold in association with the chevron angles. Based on the performance evaluation criteria, it is found that the best overall performance occurs at a chevron angle of 45 degrees. This angle is applicable in both shell side and plate side. For the shell side, the index is about 25 %, 60 %, and 340 % higher than those of beta = 75 degrees, 60 degrees, and 30 degrees, respectively at a Reynolds number of 300 at the shell side. For the plate side, the index amid beta = 75 degrees, 60 degrees, and 45 degrees is roughly the same when the Reynolds number is lower than 500, and the index is about 220 % for beta = 45 degrees when compared to beta = 30 degrees at a Reynolds number of 300.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Flow characteristics and thermal performance in chevron type plate heat exchangers
    Lee, Jonghyeok
    Lee, Kwan-Soo
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 78 : 699 - 706
  • [22] Flow characteristics and thermal performance in chevron type plate heat exchangers
    Lee, Jonghyeok
    Lee, Kwan-Soo
    International Journal of Heat and Mass Transfer, 2014, 78 : 699 - 706
  • [23] A novel wavy chevron design for plate heat exchangers: experimental and numerical analysis
    Farshidian Far, Alireza
    Bashirnezhad, Kazem
    Bashi Shahabi, Peyman
    Jahanpour, Javad
    CHEMICAL ENGINEERING COMMUNICATIONS, 2023, 210 (04) : 449 - 459
  • [24] Performance Evaluation of Plate Heat Exchanger with Chevron Angle Variations
    Kwon, Oh-kyung
    Cha, Dong-an
    Yun, Jae-ho
    Kim, Hyo-sang
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2009, 33 (07) : 520 - 526
  • [25] Fatigue performance evaluation of plate and shell heat exchangers
    Martins, G. S. M.
    da Silva, R. P. P. D.
    Beckedorff, L.
    Monteiro, A. S.
    de Paiva, K., V
    Oliveira, J. L. G.
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2020, 188 (188)
  • [26] EFFECT OF THE CORRUGATION INCLINATION ANGLE ON THE THERMOHYDRAULIC PERFORMANCE OF PLATE HEAT EXCHANGERS.
    Focke, W.W.
    Zachariades, J.
    Olivier, I.
    1600, (28):
  • [27] The characteristics of flow patterns in the shell-and-plate heat exchanger
    Wang, Ke
    Chen, Ju
    Wu, Pengfei
    Zhong, Hao
    Liu, Li
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 152 : 315 - 330
  • [28] THE EFFECT OF THE CORRUGATION INCLINATION ANGLE ON THE THERMOHYDRAULIC PERFORMANCE OF PLATE HEAT-EXCHANGERS
    FOCKE, WW
    ZACHARIADES, J
    OLIVIER, I
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1985, 28 (08) : 1469 - 1479
  • [29] Effect of chevron angle on heat transfer performance in plate heat exchanger using ZnO/water nanofluid
    Kumar, Vikas
    Tiwari, Arun Kumar
    Ghosh, Subrata Kumar
    ENERGY CONVERSION AND MANAGEMENT, 2016, 118 : 142 - 154
  • [30] Relationship between inclination angle and friction factor of chevron-type plate heat exchangers
    Zhu, Xiaowei
    Haglind, Fredrik
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 162