Mechanobiochemical bone remodelling around an uncemented acetabular component: influence of bone orthotropy

被引:0
|
作者
Saviour, Ceby Mullakkara [1 ]
Mathai, Basil [1 ,2 ]
Gupta, Sanjay [1 ]
机构
[1] Indian Inst Technol Kharagpur, Dept Mech Engn, Kharagpur 721302, West Bengal, India
[2] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, England
关键词
Pelvic bone; Total hip arthroplasty; Cementless acetabular component; Bone anisotropy; Bone adaptation; Mechanobiochemical stimulus; TOTAL HIP-ARTHROPLASTY; PARATHYROID-HORMONE; MODEL; ADAPTATION; RESORPTION; RISK; CUPS; STEM;
D O I
10.1007/s11517-024-03023-0
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Mechanical loosening of an implant is often caused by bone resorption, owing to stress/strain shielding. Adaptive bone remodelling elucidates the response of bone tissue to alterations in mechanical and biochemical environments. This study aims to propose a novel framework of bone remodelling based on the combined effects of bone orthotropy and mechanobiochemical stimulus. The proposed remodelling framework was employed in the finite element model of an implanted hemipelvis to predict evolutionary changes in bone density and associated orthotropic bone material properties. In order to account for variations in load transfer during common daily activities, several musculoskeletal loading conditions of hip joint corresponding to sitting down/up, stairs ascend/descend and normal walking were considered. The bone remodelling predictions were compared with those of isotropic strain energy density (SED)-based, isotropic mechanobiochemical and orthotropic strain-based bone remodelling formulations. Although similar trends of bone resorption were predicted by orthotropic mechanobiochemical (MBC) and orthotropic strain-based models across implanted acetabulum, more volume (10-20%) of bone elements was subjected to bone resorption for the orthotropic MBC model. Higher bone resorption (75-85%) was predicted by the orthotropic strain-based and orthotropic MBC models compared to the isotropic MBC and SED-based models. Higher bone apposition (35-160%) across the implanted acetabulum was predicted by the isotropic MBC model, compared to the SED-based model. The remodelling predictions indicated that a reduction in estrogen level might lead to an increase in bone resorption. The study highlighted the importance of including mechanobiochemical stimulus and bone anisotropy to predict bone remodelling adequately.
引用
收藏
页码:1717 / 1732
页数:16
相关论文
共 50 条
  • [21] Quantitative CT with finite element analysis: towards a predictive tool for bone remodelling around an uncemented tapered stem
    Vickie B. Shim
    Rocco P. Pitto
    Iain A. Anderson
    International Orthopaedics, 2012, 36 : 1363 - 1369
  • [22] Periprosthetic acetabular bone loss using a constrained acetabular component
    Ito, H
    Matsuno, T
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (02) : 137 - 139
  • [23] Periprosthetic acetabular bone loss using a constrained acetabular component
    Hiroshi Ito
    Takeo Matsuno
    Archives of Orthopaedic and Trauma Surgery, 2004, 124 : 137 - 139
  • [24] MICROMOTION OF THE ACETABULAR COMPONENT AND PERIACETABULAR BONE MORPHOLOGY
    ONSTEN, I
    AKESSON, K
    OBRANT, KJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (310) : 103 - 110
  • [25] The Influence of the Pelvic Bone on the Computational Results of the Acetabular Component of a Total Hip Prosthesis
    Barreto, Sara
    Folgado, Joao
    Fernandes, Paulo R.
    Monteiro, Jacinto
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (05):
  • [26] Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study
    Anderl, Conrad
    Mattiassich, Georg
    Ortmaier, Reinhold
    Steinmair, Martin
    Hochreiter, Josef
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [27] Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study
    Conrad Anderl
    Georg Mattiassich
    Reinhold Ortmaier
    Martin Steinmair
    Josef Hochreiter
    BMC Musculoskeletal Disorders, 21
  • [28] Design of a functionally graded porous uncemented acetabular component: Influence of polar gradation
    Saviour, Ceby Mullakkara
    Gupta, Sanjay
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2023, 39 (06)
  • [29] Measurement of early bone loss around an uncemented femoral stem
    Boe, Berte
    Heier, Tore
    Nordsletten, Lars
    ACTA ORTHOPAEDICA, 2011, 82 (03) : 321 - 324
  • [30] Destruction of acetabular bone caused by early failure of a constrained acetabular component
    Ito, H
    Minami, A
    Kondo, E
    Fujita, M
    Ubayama, Y
    Matsuno, T
    JOURNAL OF ARTHROPLASTY, 2001, 16 (07): : 938 - 941