A Power-Enhancing Complementary Coupling Integration Strategy for Misalignment-Tolerant WPT Systems

被引:4
|
作者
Yuan, Zhaoyang [1 ]
Yang, Qingxin [2 ]
Zhang, Xian [1 ]
Wang, Ran [1 ]
Ma, Xianjie [1 ]
Cai, Changsong [3 ]
Zhang, Pengcheng [4 ]
Lin, Hongjian [5 ]
Saeedifard, Maryam [6 ]
机构
[1] Hebei Univ Technol, State Key Lab Reliabil & Intelligence Elect Equip, Tianjin 300401, Peoples R China
[2] Tianjin Univ Technol, Tianjin 300384, Peoples R China
[3] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
[4] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[5] City Univ Hong Kong, Dept Elect Engn, Hong Kong, Peoples R China
[6] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
Complementary coupling integration; constant current (CC) output; misalignment tolerance; power enhancement; wireless power transfer (WPT); IPT SYSTEM; CHARGING SYSTEMS; DESIGN; COMPENSATION; INDUCTOR; RANGE; COILS;
D O I
10.1109/TPEL.2023.3302699
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents a complementary coupling integration method for an inductor-capacitor-capacitor-series-compensated wireless power transfer (WPT) system to improve the misalignment tolerance and power transfer capability. To this end, a compensation (Cx) coil formed by a long rectangular coil wound into a C-shaped structure is proposed. As a result, two multiples of the mutual inductance (MI) between the Cx and receiver (Rx) coils are added to the MI between the transmitter and Rx coils, providing the MI complement effect to increase the equivalent MI under both the perfectly aligned and misaligned conditions. Amathematicalmodel based on the Delta-Wye network transform is developed to obtain the zero-phase-angle (ZPA) input and load-independent constant current (CC) output conditions. A 1-kW scaled-downWPT prototype based on the proposed method is built, and its performance is experimentally validated. The proposed system achieves 85.22% efficiency at 150-mm air gap and tolerates +/- 200-mm x-, y-, and diagonal misalignments, +/- 50-mm z-misalignment, and 20. angular misalignment withZPAinput and load-independent CC output as the load varies from 5 to 20 O. In addition, the system performance is barely affected by the planar rotation misalignment.
引用
收藏
页码:14689 / 14701
页数:13
相关论文
共 50 条
  • [31] Study on Control Strategy of Hydropower Asynchronous Integration Coupling with DC Emergency Power Support
    Sun Zhongqing
    Chen Rui
    Fang Hui
    Yang Yinguo
    Chen Tao
    Liu Fusuo
    RENEWABLE ENERGY INTEGRATION WITH MINI/MICROGRID, 2018, 145 : 205 - 210
  • [32] Enhancing Renewable Energy Accommodation by Coupling Integration Optimization with Flexible Retrofitted Thermal Power Plant
    Zou, Yao
    Xia, Qinqin
    Chi, Yuan
    Wang, Qianggang
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [33] A Maximum Power Transfer Tracking Method for WPT Systems with Coupling Coefficient Identification Considering Two-Value Problem
    Dai, Xin
    Li, Xiaofei
    Li, Yanling
    Deng, Pengqi
    Tang, Chunsen
    ENERGIES, 2017, 10 (10)
  • [34] Demand response integration in microgrid planning as a strategy for energy transition in power systems
    Mina-Casaran, Juan D.
    Echeverry, Diego F.
    Lozano, Carlos A.
    IET RENEWABLE POWER GENERATION, 2021, 15 (04) : 889 - 902
  • [35] Reconfigurable Topology Design on the Secondary Side of Rotary WPT Systems for Ensuring Stable Power Transmission over Large Coupling Variation
    Ji, Li
    Zhang, Jianghong
    Zhang, Jiaqi
    Ge, Fuchen
    PROCEEDINGS OF 2023 INTERNATIONAL CONFERENCE ON WIRELESS POWER TRANSFER, VOL 1, ICWPT 2023, 2024, 1158 : 330 - 337
  • [36] Enhancing Privacy Strategy in New Power Systems: Problem Assessment, Comparative Analysis and Suggestions
    Chen, Li
    Yao, Xuyan
    Zhang, Xin
    Cao, Yuxin
    Su, Jiahe
    Tian, Yuan
    BIG DATA AND SECURITY, ICBDS 2023, PT II, 2024, 2100 : 145 - 153
  • [37] Decision-making strategy for cogeneration power systems integration in the Lebanese electricity grid
    Al Asmar, Joseph
    Lahoud, Chawki
    Brouche, Marwan
    INTERNATIONAL CONFERENCE ON TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY, TMREES17, 2017, 119 : 801 - 805
  • [38] The Operation Strategy of the MIDC Systems for Optimizing Renewable Energy Integration of Jeju Power System
    Son, Hyeokjin
    Jang, Gilsoo
    ENERGIES, 2023, 16 (15)
  • [39] Enhancing the economic efficiency of wind-photovoltaic-hydrogen complementary power systems via optimizing capacity allocation
    Wei, Daohong
    He, Mengwei
    Zhang, Jingjing
    Liu, Dong
    Mahmud, Md. Apel
    JOURNAL OF ENERGY STORAGE, 2024, 104
  • [40] Innovative Power Smoothing Technique for Enhancing Renewable Integration in Insular Power Systems Using Electric Vehicle Charging Stations
    Villa-Avila, Edisson
    Arevalo, Paul
    Ochoa-Correa, Danny
    Iniguez-Moran, Vinicio
    Jurado, Francisco
    APPLIED SCIENCES-BASEL, 2024, 14 (01):