Modified endurance time method for seismic performance assessment of base-isolated structures

被引:13
|
作者
Movahhed, Ataallah Sadeghi [1 ]
Shirkhani, Amir [2 ]
Zardari, Saeid [3 ]
Mashayekhi, Mohammadreza [4 ]
Farsangi, Ehsan Noroozinejad [5 ]
Majdi, Ali [6 ]
机构
[1] Islamic Azad Univ, Dept Civil Engn, Shabestar Branch, Shabestar, Iran
[2] Univ Tabriz, Fac Civil Engn, Dept Struct Engn, Tabriz, Iran
[3] Istanbul Okan Univ, Dept Civil Engn, Istanbul, Turkiye
[4] K N Toosi Univ Technol, Dept Civil Engn, Tehran, Iran
[5] Grad Univ Adv Technol, Fac Civil & Surveying Engn, Kerman, Iran
[6] Al Mustaqbal Univ Coll, Dept Bldg & Construct Tech Engn, Hillah 51001, Babylon, Iraq
来源
关键词
Endurance time method; Endurance time excitation functions; Nonlinear time history analysis; Base isolation system; Modified endurance time method; Seismic resilience; SLIDING ISOLATION BEARINGS; STRONG-MOTION DURATION; STEEL FRAMES; ADAPTIVE-BEHAVIOR; FRICTION; EXCITATIONS; DESIGN;
D O I
10.1016/j.jobe.2023.105955
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Endurance time (ET) method is a novel Time History Analysis (THA) approach in which structures are subjected to a set of intensifying excitations called endurance time excitation functions (ETEF). Although various studies show the efficiency of the ET method for the seismic evaluation of fixed base structures, this method has been less employed in isolated structures. The lack of coverage of high-intensity measures by existing ETEFs is the major obstacle to adopting the ET method in high-period structures such as isolated structures. It must be noted that high-intensity measures that are associated with large earthquakes are of paramount importance in performance assessment. This paper introduced a novel method called the modified endurance time (MET) method based on scaling existing ETEFs to alleviate this problem. By averaging multiple scaled ETEFs, the accuracy of the ET method is improved. Three steel structures with a different number of stories (6, 9, and 12), including Intermediate Moment Frames (IMFs), mounted on Triple Friction Pendulum Isolators (TFPIs) are considered to demonstrate the efficiency of the proposed method. These structures are analyzed under ETEFs with intensity multipliers 1 to 4 for three seismic hazard levels with return periods of 72, 475, and 2475 years. The effect of changing parameters such as isolator damping and period is also investigated on the results. The seismic responses obtained from the Endurance Time Analysis (ETA) are compared with the responses obtained from the nonlinear THA and pushover analysis. Results show that increasing the intensity multiplier of ETEFs can greatly improve the accuracy of results. However, it should be careful in the procedure of selecting the appropriate intensity multiplier. Because of the unbalanced changes in some ETEFs parameters such as PGV/PGA, the accuracy of results may also reduce by increasing the intensity multiplier. Therefore, the use of different combinations of results, obtained from several intensity multipliers, is investigated and proposed to reduce the error in results.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Parametric Study on Seismic Energy Response of Base-isolated Structures
    Wu, Chenghao
    Li, Yu
    Li, Haoyu
    Zhang, Kai
    WMSO: 2008 INTERNATIONAL WORKSHOP ON MODELLING, SIMULATION AND OPTIMIZATION, PROCEEDINGS, 2009, : 375 - 378
  • [42] Seismic performance assessment and base-isolated floor protection of statues exhibited in museum halls
    Stefano Sorace
    Gloria Terenzi
    Bulletin of Earthquake Engineering, 2015, 13 : 1873 - 1892
  • [43] Seismic performance assessment and base-isolated floor protection of statues exhibited in museum halls
    Sorace, Stefano
    Terenzi, Gloria
    BULLETIN OF EARTHQUAKE ENGINEERING, 2015, 13 (06) : 1873 - 1892
  • [44] Seismic Performance Assessment of SMRF Structures Subjected to Mainshock-Aftershock Seismic Sequences by Endurance Time Method
    Farivarrad, Amir H.
    Estekanchi, Homayoon E.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (07) : 3281 - 3299
  • [45] Experimental seismic performance of a base-isolated building with displacement limiters
    Du, Hongkai
    Wang, Yuandong
    Han, Miao
    Ibarra, Luis F.
    ENGINEERING STRUCTURES, 2021, 244
  • [46] Seismic performance of a building base-isolated by TFP to with a moat wall
    Movahhed, Ataallah Sadeghi
    Zardari, Saeid
    Sadoglu, Erol
    EARTHQUAKES AND STRUCTURES, 2022, 23 (01) : 87 - 100
  • [47] Effect of structural details on seismic performance of base-isolated bridges
    Chaudhary, MT
    Abé, M
    Fujino, Y
    PROCEEDINGS OF IMAC-XIX: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, 2001, 4359 : 1351 - 1357
  • [48] Seismic performance of base-isolated structures for swimming pool reactors under different foundation conditions
    Zhao, Jie
    Wang, Jianshan
    Huang, Jiehua
    PLOS ONE, 2024, 19 (10):
  • [49] Simplified inelastic seismic analysis of base-isolated structures using the N2 method
    Kilar, Vojko
    Koren, David
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (09): : 967 - 989
  • [50] DAMPING EFFECTS ON THE SEISMIC RESPONSE OF BASE-ISOLATED STRUCTURES WITH LRB DEVICES
    Avossa, Alberto Maria
    Pianese, Giovanna
    INGEGNERIA SISMICA, 2017, 34 (02): : 3 - 30