Modified endurance time method for seismic performance assessment of base-isolated structures

被引:13
|
作者
Movahhed, Ataallah Sadeghi [1 ]
Shirkhani, Amir [2 ]
Zardari, Saeid [3 ]
Mashayekhi, Mohammadreza [4 ]
Farsangi, Ehsan Noroozinejad [5 ]
Majdi, Ali [6 ]
机构
[1] Islamic Azad Univ, Dept Civil Engn, Shabestar Branch, Shabestar, Iran
[2] Univ Tabriz, Fac Civil Engn, Dept Struct Engn, Tabriz, Iran
[3] Istanbul Okan Univ, Dept Civil Engn, Istanbul, Turkiye
[4] K N Toosi Univ Technol, Dept Civil Engn, Tehran, Iran
[5] Grad Univ Adv Technol, Fac Civil & Surveying Engn, Kerman, Iran
[6] Al Mustaqbal Univ Coll, Dept Bldg & Construct Tech Engn, Hillah 51001, Babylon, Iraq
来源
关键词
Endurance time method; Endurance time excitation functions; Nonlinear time history analysis; Base isolation system; Modified endurance time method; Seismic resilience; SLIDING ISOLATION BEARINGS; STRONG-MOTION DURATION; STEEL FRAMES; ADAPTIVE-BEHAVIOR; FRICTION; EXCITATIONS; DESIGN;
D O I
10.1016/j.jobe.2023.105955
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Endurance time (ET) method is a novel Time History Analysis (THA) approach in which structures are subjected to a set of intensifying excitations called endurance time excitation functions (ETEF). Although various studies show the efficiency of the ET method for the seismic evaluation of fixed base structures, this method has been less employed in isolated structures. The lack of coverage of high-intensity measures by existing ETEFs is the major obstacle to adopting the ET method in high-period structures such as isolated structures. It must be noted that high-intensity measures that are associated with large earthquakes are of paramount importance in performance assessment. This paper introduced a novel method called the modified endurance time (MET) method based on scaling existing ETEFs to alleviate this problem. By averaging multiple scaled ETEFs, the accuracy of the ET method is improved. Three steel structures with a different number of stories (6, 9, and 12), including Intermediate Moment Frames (IMFs), mounted on Triple Friction Pendulum Isolators (TFPIs) are considered to demonstrate the efficiency of the proposed method. These structures are analyzed under ETEFs with intensity multipliers 1 to 4 for three seismic hazard levels with return periods of 72, 475, and 2475 years. The effect of changing parameters such as isolator damping and period is also investigated on the results. The seismic responses obtained from the Endurance Time Analysis (ETA) are compared with the responses obtained from the nonlinear THA and pushover analysis. Results show that increasing the intensity multiplier of ETEFs can greatly improve the accuracy of results. However, it should be careful in the procedure of selecting the appropriate intensity multiplier. Because of the unbalanced changes in some ETEFs parameters such as PGV/PGA, the accuracy of results may also reduce by increasing the intensity multiplier. Therefore, the use of different combinations of results, obtained from several intensity multipliers, is investigated and proposed to reduce the error in results.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Application of the Modified Endurance Time Method for Predicting Seismic Response of Base-Isolated Structures Under Pounding
    Majdi, Ali
    Sadeghi-Movahhed, Ataallah
    Farsangi, Ehsan Noroozinejad
    Mashayekhi, Mohammadreza
    Almujibah, Hamad
    De Domenico, Dario
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2025,
  • [2] Seismic performance assessment of base-isolated safety-related nuclear structures
    Huang, Yin-Nan
    Whittaker, Andrew S.
    Luco, Nicolas
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (13): : 1421 - 1442
  • [3] Modified tuned Maxwell-Wiechert model for improving seismic performance of base-isolated structures
    Liu, Wei
    Ikago, Kohju
    Wu, Zhanzhan
    Fukuda, Iori
    JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [4] Seismic performance assessment of fixed offshore structures by endurance time method
    Diznab, Mohammad Ali Dastan
    Mehdigholi, Hamid
    Seif, Mohammad Saeed
    SHIPS AND OFFSHORE STRUCTURES, 2019, 14 (07) : 709 - 722
  • [5] Seismic behavior of rocking base-isolated structures
    Cheng, Chin -Tung
    Chao, Chih-Hung
    ENGINEERING STRUCTURES, 2017, 139 : 46 - 58
  • [6] Influence of FPS bearing properties on the seismic performance of base-isolated structures
    Castaldo, Paolo
    Tubaldi, Enrico
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (15): : 2817 - 2836
  • [7] Performance Evaluation of Base-Isolated Structures
    Chimamphant, Sarun
    Kasai, Kazuhiko
    JOURNAL OF DISASTER RESEARCH, 2015, 10 (04) : 647 - 654
  • [8] Seismic performance of a base-isolated demonstration building
    Taniwangsa, W
    EARTHQUAKE SPECTRA, 2002, 18 (04) : 777 - 793
  • [9] Seismic performance evaluation of base-isolated bridges
    Abé, M
    Fujino, Y
    Yoshida, J
    CONTROL IN NATURAL DISASTERS (CND'98), 1999, : 117 - 121
  • [10] SEISMIC RELIABILITY ASSESSMENT OF YIELDING BASE-ISOLATED STRUCTURES FOR AN INTERMEDIATE ISOLATION DEGREE
    Alfano, Gaetano