A Comprehensive Analysis of the Penetration of Detailed Type 4 Wind Turbine Generators in the Two-Area Benchmark System

被引:1
|
作者
Trentini, Rodrigo [1 ]
Kutzner, Ruediger [2 ]
Saldanha, John J. A. [1 ,3 ]
Nied, Ademir [3 ]
Dezuo, Tiago Jackson May [3 ]
Cavalca, Mariana Santos Matos [3 ]
机构
[1] Fed Inst Santa Catarina, Dept Elect Engn, IFSC, R Imigrantes 445, BR-89254430 Jaragua Do Sul, Brazil
[2] Univ Appl Sci & Arts Hannover HsH, Dept Control Engn & Mechatron, D-30459 Hannover, Germany
[3] Santa Catarina State Univ, Dept Elect Engn, UDESC, R Paulo Malschitzki 200, BR-89219710 Joinville, Brazil
关键词
renewable energy sources; wind turbine generator; penetration of RES; two-area benchmark system; inverter-based resources; POWER-SYSTEM; STABILITY;
D O I
10.3390/en16134970
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The shift towards RES introduces challenges related to power system stability due to the characteristics of inverter-based resources (IBRs) and the intermittent nature of renewable resources. This paper addresses these challenges by conducting comprehensive time and frequency simulations on the IEEE two-area benchmark power system with detailed type 4 wind turbine generators (WTGs), including turbines, generators, converters, filters, and controllers. The simulations analyse small-signal and transient stability, considering variations in active and reactive power, short-circuit events, and wind variations. Metrics such as rate of change of frequency (RoCoF), frequency nadir, percentage of frequency variation, and probability density function (PDF) are used to evaluate the system performance. The findings emphasise the importance of including detailed models of RES in stability analyses and demonstrate the impact of RES penetration on power system dynamics. This study contributes to a deeper understanding of RES integration challenges and provides insights for ensuring the reliable and secure operation of power systems in the presence of high levels of RES penetration.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Effective participation of wind turbines in frequency control of a two-area power system using coot optimization
    Mahmoud Hussain El-Bahay
    Mohammed Elsayed Lotfy
    Mohamed A. El-Hameed
    Protection and Control of Modern Power Systems, 2023, 8
  • [22] Impact assessment of virtual synchronous generator on the electromechanical dynamics of type 4 wind turbine generators
    Tessaro, Heitor Jose
    de Oliveira, Ricardo Vasques
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (23) : 5294 - 5304
  • [23] Determination of the Optimum Capacity and Type of Wind Turbine Generators in a Power System Considering Reliability and Cost
    Xie, Kaigui
    Billinton, Roy
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 227 - 234
  • [24] Two-Area System Analysis and Control Using Real-Time Digital Simulator
    Fares, Abdou
    Nazari, Masoud H.
    Castaneda, Juan
    Chassiakos, Anastasios
    2016 IEEE GREEN ENERGY AND SYSTEMS CONFERENCE (IGSEC), 2016,
  • [25] Stability Improvement of a Two-Area Power System Connected with an Integrated Onshore and Offshore Wind Farm Using a STATCOM
    Wang, Li
    Chang, Che-hao
    Prokhorov, Anton V.
    2016 52ND ANNUAL MEETING OF THE IEEE INDUSTRY APPLICATIONS SOCIETY (IAS), 2016,
  • [26] Modelling and Analysis of Type 4 Wind Turbine Generator System For Utilization In Frequency Regulation Studies
    Aziz, Asma
    Mto, Amanullah
    Stojcevski, Alex
    2015 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2015,
  • [27] Stability Improvement of a Two-Area Power System Connected With an Integrated Onshore and Offshore Wind Farm Using a STATCOM
    Wang, Li
    Chang, Che-Hao
    Kuan, Bing-Lin
    Prokhorov, Anton V.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (02) : 867 - 877
  • [28] Effects of two-area variable inertia on transient stabilisation in interconnected power system with DFIG-based wind turbines
    Zhang, Xiangyu
    Fu, Yuan
    Wang, Shuang
    Wang, Yi
    IET RENEWABLE POWER GENERATION, 2017, 11 (05) : 696 - 706
  • [29] Transient Stability Analysis of the Two-Area With AC/DC Paralleled Interconnected Power System in Different Operation
    Liu, Hongbo
    Zhang, Shuyu
    Sun, Li
    Zhang, Chong
    Peng, Xiaoyu
    FRONTIERS IN ENERGY RESEARCH, 2021, 9
  • [30] Generic dynamic wind turbine models for power system stability analysis: A comprehensive review
    Honrubia-Escribano, A.
    Gomez-Lazaro, E.
    Fortmann, J.
    Sorensen, P.
    Martin-Martinez, S.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 : 1939 - 1952