3D ultrasound strain imaging of puborectal muscle with and without unilateral avulsion

被引:0
|
作者
Das, Shreya [1 ]
Hendriks, Gijs A. G. M. [1 ]
van den Noort, Frieda [2 ]
Manzini, Claudia [3 ]
van der Vaart, C. H. [3 ]
de Korte, Chris L. [1 ,4 ]
机构
[1] Radboud Univ Nijmegen, Med Ultrasound Imaging Ctr, Dept Med Imaging, Med Ctr, Geert Grootepl Zuid 10 767,POB 9101 766, NL-6500 HB Nijmegen, Netherlands
[2] Univ Twente, Tech Med Ctr, Robot & Mechatron, Enschede, Netherlands
[3] Univ Med Ctr, Dept Reprod Med & Gynecol, Utrecht, Netherlands
[4] Univ Twente, TechMed Ctr, Phys Fluids, Enschede, Netherlands
关键词
Ultrasound; Puborectal muscle; Unilateral avulsion; PELVIC FLOOR; WOMEN;
D O I
10.1007/s00192-023-05498-1
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction and hypothesisThe puborectal muscle (PRM), one of the female pelvic floor (PF) muscles, can get damaged during vaginal delivery, leading to disorders such as pelvic organ prolapse. Current diagnosis involves ultrasound (US) imaging of the female PF muscles, but functional information is limited. Previously, we developed a method for strain imaging of the PRM from US images in order to obtain functional information. In this article, we hypothesize that strain in the PRM would differ from intact to the avulsed end.MethodsWe calculated strain in PRMs at maximum contraction, along their muscle fiber direction, from US images of two groups of women, which consisted of women with intact (n(1) = 8) and avulsed PRMs (unilateral) (n(2) = 10). Normalized strain ratios between both ends of the PRM (avulsed or intact) and the mid region were calculated. Subsequently, the difference in ratio between the avulsed and intact PRMs was determined.ResultsWe observe from the obtained results that the contraction/strain pattern of intact and undamaged PRMs is different from PRMs with unilateral avulsion. Normalized strain ratios between avulsed and intact PRMs were statistically significant (p = 0.04).ConclusionIn this pilot study, we were able to show that US strain imaging of PRMs can show differences between intact PRMs and PRMs with unilateral avulsion.
引用
收藏
页码:2225 / 2233
页数:9
相关论文
共 50 条
  • [31] In Vivo 3D Cardiac and Skeletal Muscle Strain Estimation
    Lopata, Richard G. P.
    Nillesen, Maartje M.
    Gerrits, Inge H.
    Thijssen, Johan M.
    Kapusta, Livia
    van de Vosse, Frans N.
    de Korte, Chris L.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 744 - +
  • [32] DIFFERENCES IN LEVATOR HIATAL DIMENSIONS AND PUBORECTALIS MUSCLE LENGTH IN WOMEN WITH AND WITHOUT PROVOKED VESTIBULODYNIA EVALUATED USING 3D/4D TRANSPERINEAL ULTRASOUND IMAGING
    Thibault-Gagnon, S.
    McLean, L.
    Pukall, C.
    Goldfinger, C.
    Chamberlain, S.
    JOURNAL OF SEXUAL MEDICINE, 2011, 8 : 57 - 57
  • [33] Prenatal diagnosis of unilateral megalencephaly by 2D and 3D ultrasound: A case report
    Hafner, E
    Bock, W
    Zoder, G
    Schuchter, K
    Rosen, A
    Plattner, M
    PRENATAL DIAGNOSIS, 1999, 19 (02) : 159 - 162
  • [34] 3D Fetal Face Reconstruction from Ultrasound Imaging
    Alomar, Antonia
    Morales, Araceli
    Vellve, Kilian
    Porras, Antonio R.
    Crispi, Fatima
    Linguraru, Marius George
    Piella, Gemma
    Sukno, Federico
    VISAPP: PROCEEDINGS OF THE 16TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS - VOL. 4: VISAPP, 2021, : 615 - 624
  • [35] 3D printed phantom for high frequency ultrasound imaging
    Jacquet, Jean-Rene
    Levassort, Franck
    Ossant, Frederic
    Gregoire, Jean-Marc
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [36] A Linear Slide Platform for 3D Ocular Ultrasound Imaging
    Qureshi, Amad
    Ryan, Andrew
    Huang, Yidi
    Yao, Ningshi
    Demer, Joseph L.
    Wei, Qi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [37] Elevation Resolution Enhancement Oriented 3D Ultrasound Imaging
    Fan, Kai
    Cai, Yunye
    Shen, Enxiang
    Wang, Yuxin
    Yuan, Jie
    Tao, Chao
    Liu, Xiaojun
    ULTRASONIC IMAGING, 2024, 46 (4-5) : 220 - 232
  • [38] Reconstruction error in 3D ultrasound imaging with mechanical probes
    Cao, Ji
    Karaday, Kerem
    Managuli, Ravi
    Kim, Yongmin
    MEDICAL IMAGING 2010: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2010, 7629
  • [39] Tackling the Bottleneck of Delay Tables in 3D Ultrasound Imaging
    Ibrahim, A.
    Hager, P.
    Bartolini, A.
    Angiolini, F.
    Arditi, M.
    Benini, L.
    De Micheli, G.
    2015 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE), 2015, : 1683 - 1688
  • [40] 3D Ultrasound Imaging in Image-Guided Intervention
    Fenster, Aaron
    Bax, Jeff
    Neshat, Hamid
    Cool, Derek
    Kakani, Nirmal
    Romagnoli, Cesare
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6151 - 6154