Thermal and draught perception in fluctuating stratified thermal environments with intermittent impinging jet ventilation

被引:5
|
作者
Zhou, Bin [1 ]
Li, Zhe [1 ]
Yang, Bin [2 ]
Li, Xiaojing [1 ]
Wang, Faming [3 ]
Wei, Shen [4 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[3] Katholieke Univ Leuven, Dept Biosyst, B-3001 Leuven, Belgium
[4] Univ Coll London UCL, Bartlett Sch Sustainable Construct, London WC1E 7HB, England
基金
中国国家自然科学基金;
关键词
Thermal comfort; Impinging jet ventilation; Intermittent air supply; Fluctuated thermal environment; Draught sensation; AIR SUPPLY-SYSTEM; DISPLACEMENT VENTILATION; COMFORT; FLOW; QUALITY; ROOMS;
D O I
10.1016/j.buildenv.2022.109934
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes a new integrated air supply strategy of impinging jet ventilation (IJV) and intermittent airflow to improve indoor thermal comfort. Vertical thermal stratification is created by the IJV, and a fluctuating thermal environment is created by the intermittent airflow. Three pulsating periods (3 min, 5 min, and 7 min), two supply air temperatures (18 degrees C and 16 degrees C), and four air supply velocities (1.8 m/s steady, 1.5/2.1 m/s, 0.9/ 2.7 m/s, and 0/3.6 m/s) were designed. In both steady and fluctuating indoor environments, fifteen college students were asked to report their perceptions of thermal sensation, thermal comfort, thermal preference, ankle air movement acceptability and preference, and perceived air quality. The results showed that pulsating airflow could lower the mean air temperature above 0.6 m and raise it below 0.6 m. Furthermore, pulsating airflow could reduce overall and local thermal sensation by up to 0.21 and 0.28 scale unit, respectively, and the thermal sensation difference between the head and the foot by up to 0.23 scale unit. While in neutral thermal conditions, the pulsating period of 3 min had the best cooling effect of the 10 cases, but the corresponding percentage of mean dissatisfied ankle draught was 4.3% higher than in the steady operation case. Draught sensation is so closely related to ankle thermal sensation that extending the pulsating periods to 5 or 7 min could reduce ankle draught risk by up to 12.3%. The perceived air quality did not differ significantly between the steady and intermittent cases. The intermittent operation of IJV was shown to have superior cooling performance in order to improve indoor thermal comfort.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Modeling thermal comfort in stratified environments
    Zhang, H
    Huizenga, C
    Arens, E
    Yu, T
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 133 - 137
  • [22] Numerical investigation of indoor thermal comfort and air quality for an office equipped with corner impinging jet ventilation
    Ameen, Arman
    Cehlin, Mathias
    Karimipanah, Taghi
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (05) : 578 - 604
  • [23] Geometric-parameter influence and orthogonal evaluation on the thermal environment for an impinging jet ventilation system inlet
    Wang, Chen
    Zhang, Xiaoying
    Hu, Ke
    Liu, Yin
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 51
  • [24] Simplified models for predicting thermal stratification in impinging jet ventilation rooms using multiple regression analysis
    Hu, Jun
    Kang, Yanming
    Lu, Yihang
    Yu, Jia
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2021, 206
  • [25] Study of indoor local thermal comfort for impinging jet ventilation combined with ductless personalized ventilation under different cooling loads
    Duan, Tao
    Ye, Xiao
    Du, Peng
    Qi, Hechuang
    Kang, Yanming
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2024, 265
  • [26] The effect of short pin fin aspect ratio on thermal characteristics of intermittent impinging jet; An experimental and numerical study
    Yousefi-Lafouraki, Babak
    Zargarabadi, Mehran Rajabi
    Sunden, Bengt
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 148
  • [27] Evaluation of thermal comfort, IAQ and energy consumption in an impinging jet ventilation (IJV) system with/without ceiling exhaust
    Haghshenaskashani, Samira
    Sajadi, Behrang
    JOURNAL OF BUILDING ENGINEERING, 2018, 18 : 142 - 153
  • [28] Selection and variation in size and growth in fluctuating thermal environments
    Kingsolver, JG
    Izem, R
    Ragland, G
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2003, 43 (06) : 922 - 922
  • [29] Predicting the physiological performance of ectotherms in fluctuating thermal environments
    Niehaus, Amanda C.
    Angilletta, Michael J., Jr.
    Sears, Michael W.
    Franklin, Craig E.
    Wilson, Robbie S.
    JOURNAL OF EXPERIMENTAL BIOLOGY, 2012, 215 (04): : 694 - 701
  • [30] Adaptation of thermal reaction norms in constant and fluctuating environments
    Suleiman, Abdulrahaman Lawal
    Landi, Pietro
    Hui, Cang
    EVOLUTIONARY ECOLOGY, 2025, : 209 - 224