Depth-profiling analysis of ZnO layers with three morphologies by direct-current glow discharge mass spectrometry

被引:4
|
作者
Huang, Lei [1 ,2 ]
Zeng, Wang [1 ,2 ]
Qian, Rong [1 ,2 ]
Zhuo, Shangjun [1 ,2 ]
Gu, Zheming [3 ]
Liu, Anqi [1 ,2 ]
Gao, Jie [1 ,2 ]
Chen, Qiao [4 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Natl Ctr Inorgan Mass Spectrometry Shanghai, Shanghai 200050, Peoples R China
[2] Univ Chinese Acad Sci, Ctr Mat Sci & Optoelect Engn, Beijing 100864, Peoples R China
[3] Shanghai Res Inst Mat, Shanghai 200080, Peoples R China
[4] Univ Sussex, Sch Life Sci, Dept Chem, Brighton BN1 9QJ, England
基金
中国国家自然科学基金;
关键词
Glow discharge mass spectrometry; Depth-profiling analysis; ZnO layer; Morphology; Thickness; Depth resolution; NANOPARTICLES; SPECTROSCOPY; ELEMENTS;
D O I
10.1016/j.microc.2023.108904
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the fabrication of high-quality materials, information regarding the element concentration and distribution in the depth direction is particularly important. In this study, the potential applicability of direct-current glow discharge mass spectrometry (dc-GD-MS) was explored for depth-profiling analysis of zinc oxide (ZnO) layers on steel substrates. The ZnO layers on steel substrates presented three morphologies of thin films, network textures and nanorods fabricated by magnetron sputtering (ZnO-1/steel), sol-gel method (ZnO-2/steel) and hydrothermal synthesis (ZnO-3/steel), respectively. The discharge conditions were optimized based on dc-GD-MS to obtain the ideal depth resolutions. The results revealed that compared with ZnO layers of ZnO-2/steel and ZnO-3/steel, the dc-GD-MS depth-profiling analysis of ZnO-1/steel presented superior performance with depth resolution of 0.22 mu m and a clear interface between ZnO layer and steel substrate. dc-GD-MS depth-profiling analysis suggested that the ZnO layer morphology, thickness and sputtering rate could affect the depth resolution. Furthermore, the fuzzy synthetic evaluation method (FSEM) suggested that the layer morphology had a greater impact on the depth resolutions than thickness and sputtering rate under the optimized discharge conditions. The study presented an efficient and sensitive approach for determining the elemental concentrations and distributions of semi-conducting materials, offering novel insights into material fabrication.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] MASS-SPECTROMETRY STUDY OF A MAGNETRON PLANAR GLOW-DISCHARGE EXCITED IN THE DIRECT-CURRENT AND IN THE RADIOFREQUENCY MODE - AN EXPERIMENTAL-DESIGN APPROACH
    MOLLE, C
    SPRINGAEL, S
    WAUTELET, M
    DAUCHOT, JP
    HECQ, M
    APPLIED SPECTROSCOPY, 1995, 49 (07) : 872 - 879
  • [32] Microsecond pulsed versus direct current glow discharge as ion sources for analytical glow discharge-time of ight mass spectrometry
    Martin, Antonio
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (09) : 1179 - 1183
  • [33] Microsecond pulsed versus direct current glow discharge as ion sources for analytical glow discharge-time of flight mass spectrometry
    Martín, Antonio
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    Journal of Analytical Atomic Spectrometry, 2007, 22 (09): : 1179 - 1183
  • [34] Improvement of analyte to interferent line intensity ratio in direct current glow discharge mass spectrometry
    Oksenoid, KG
    Liebich, V
    Pietzsch, G
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 355 (7-8): : 863 - 865
  • [35] Improvement of analyte to interferent line intensity ratio in direct current glow discharge mass spectrometry
    N.S. Kurnakov Institute of General, and Inorganic Chemistry, Russian, Academy of Sciences, 31 Leninsky, 117907 Moscow, Russia
    Fresenius J Anal Chem, 7-8 (863-865):
  • [36] Depth profiling by pulsed glow discharge time-of-flight mass spectrometry with a combined hollow cathode cell
    Gubal, Anna
    Chuchina, Victoria
    Lyalkin, Yegor
    Mikhailovskii, Vladimir
    Yakobson, Viktor
    Solovyev, Nikolay
    Ganeev, Alexander
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (08) : 1587 - 1596
  • [37] ELEMENTAL COMPOSITION PROFILING IN THIN-FILMS BY GLOW-DISCHARGE MASS-SPECTROMETRY - DEPTH RESOLUTION
    COBURN, JW
    ECKSTEIN, EW
    KAY, E
    JOURNAL OF APPLIED PHYSICS, 1975, 46 (07) : 2828 - 2830
  • [38] Glow discharge optical emission spectrometry (GDOES) depth profiling analysis of anodic alumina film - a depth resolution study
    Shimizu, K
    Brown, GM
    Habazaki, H
    Kobayashi, G
    Skeldon, P
    Thompson, GE
    Wood, GC
    SURFACE AND INTERFACE ANALYSIS, 1999, 27 (01) : 24 - 28
  • [39] Application of glow discharge mass spectrometry for direct trace impurity analysis in Cu films
    Lim, JW
    Mimura, K
    Isshiki, A
    APPLIED SURFACE SCIENCE, 2004, 227 (1-4) : 300 - 305
  • [40] RELATIVE SENSITIVITY FACTORS IN DIRECT-CURRENT GLOW-DISCHARGE MASS-SPECTROMETRY USING KR AND XE GAS - ESTIMATION OF THE ROLE OF PENNING IONIZATION
    SAITO, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (2-3): : 148 - 153