FINITE ELEMENT ANALYSIS OF CUSTOMIZED KNEE IMPLANTS BY VARYING LOADS DURING FLEXION-EXTENSION MOVEMENT

被引:0
|
作者
Alshewaier, Shady A. A. [1 ]
Alshehri, Majed Ali Ghurmallah [2 ]
Begum, S. Sabarunisha [3 ]
Sikkandar, Mohamed Yacin [2 ]
Almukil, Ali Abdullah A. [2 ]
Alhazmi, Aishah Mohammad [4 ]
机构
[1] Majmaah Univ, Coll Appl Med Sci, Dept Phys Therapy, Al Majmaah 11952, Saudi Arabia
[2] Majmaah Univ, Coll Appl Med Sci, Dept Med Equipment Technol, Al Majmaah 11952, Saudi Arabia
[3] PSR Engn Coll, Dept Biotechnol, Sivakasi 626140, Tamil Nadu, India
[4] Ad Diriyah Hosp, Minist Hlth, Diriyah, Saudi Arabia
关键词
Total knee replacement; knee osteoarthritis; off-the-shelf knee; patient-specific; biomechanical; ARTHROPLASTY; BIOMECHANICS;
D O I
10.1142/S021951942340016X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A customized knee implant numerical modeling using finite element analysis (FEA) during flexion extension has been investigated in this paper with varying loads with an objective of studying its kinematics. Computed tomography (CT) images of 15 osteoarthritis subjects' images were used in this work. Various morphological characteristics were extracted from clinical images using a commercial CAE software and biomechanical properties were studied on applying standard loads on customized implant and off-the-shelf (OTS) implants. Patient-specific knee implants have been designed according to the morphological characteristics and bone dimension of patient with compressive loads (1500, 1700 and 3000 N) during normal gait and were compared with the normal knee. Results showed that the stresses are distributed equally to the spacer and the tibial plate, unlike the standard femoral component where the stresses get concentrated on the cut edges. In compressive load, active stress and strain (similar to 5-20 MPa) are lesser (similar to 5%) and in flexion extension also lesser with a scaling factor of 0.785 and 1.0. The designed implant was found to produce similar biomechanical properties when compared to normal knee joint and thus it can be considered as a valuable implant and could replace the standard OTS knee implants.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] FORCES ACTING ON THE PATELLA DURING MAXIMAL VOLUNTARY CONTRACTION OF THE QUADRICEPS FEMORIS MUSCLE AT DIFFERENT KNEE FLEXION-EXTENSION ANGLES
    VANEIJDEN, TMGJ
    WEIJS, WA
    KOUWENHOVEN, E
    VERBURG, J
    ACTA ANATOMICA, 1987, 129 (04): : 310 - 314
  • [42] Computational study of kinematics of the anterior cruciate ligament double-bundle structure during passive knee flexion-extension
    Otani, Tomohiro
    Kobayashi, Yo
    Tanaka, Masao
    MEDICAL ENGINEERING & PHYSICS, 2020, 83 : 56 - 63
  • [43] Estimation of 2-D Center of Mass Movement During Trunk Flexion-Extension Movements Using Body Accelerations
    Betker, Aimee L.
    Szturm, Tony
    Moussavi, Zahra M. K.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2009, 17 (06) : 553 - 559
  • [44] Cervical Motion Segment Percent Contributions to Flexion-Extension During Continuous Functional Movement in Control Subjects and Arthrodesis Patients
    Anderst, William J.
    Donaldson, William F., III
    Lee, Joon Y.
    Kang, James D.
    SPINE, 2013, 38 (09) : E533 - E539
  • [45] Movement of the posterior cruciate ligament during knee flexion - MRI analysis
    Komatsu, T
    Kadoya, Y
    Nakagawa, S
    Yoshida, G
    Takaoka, K
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (02) : 334 - 339
  • [46] The Study of Contact Pressure of a Customized Knee Spacer Using Finite Element Analysis
    Choh, Alex C. T.
    Ng, Jaryl C. K.
    Yew, Andy K. S.
    Chia Shi-Lu
    Chong, Desmond Y. R.
    7TH WACBE WORLD CONGRESS ON BIOENGINEERING 2015, 2015, 52 : 92 - 95
  • [47] Characterizing forearm muscle activity in young adults during dynamic wrist flexion-extension movement using a wrist robot
    Forman, Davis A.
    Forman, Garrick N.
    Avila-Mireles, Edwin J.
    Mugnosso, Maddalena
    Zenzeri, Jacopo
    Murphy, Bernadette
    Holmes, Michael W. R.
    JOURNAL OF BIOMECHANICS, 2020, 108
  • [48] Finite element modeling and analysis of effect of preexisting cervical degenerative disease on the spinal cord during flexion and extension
    Meng-lei Xu
    Yi-ting Yang
    Hui-zi Zeng
    Yu-ting Cao
    Liang-dong Zheng
    Chen Jin
    Shi-jie Zhu
    Rui Zhu
    Medical & Biological Engineering & Computing, 2024, 62 : 1089 - 1104
  • [49] Finite element modeling and analysis of effect of preexisting cervical degenerative disease on the spinal cord during flexion and extension
    Xu, Meng-lei
    Yang, Yi-ting
    Zeng, Hui-zi
    Cao, Yu-ting
    Zheng, Liang-dong
    Jin, Chen
    Zhu, Shi-jie
    Zhu, Rui
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (04) : 1089 - 1104
  • [50] Activation EMG pattern during isokinetic knee flexion-extension assessment: Comparison between healthy subjects and chronic pain patients
    Maquet, D
    Demoulin, C
    Forthomme, B
    Crielaard, JM
    Croisier, JL
    ISOKINETICS AND EXERCISE SCIENCE, 2005, 13 (01) : 5 - 11