Electrocardiogram Belt guidance for left ventricular lead placement and biventricular pacing optimization

被引:10
|
作者
Rickard, John [1 ,10 ]
Jackson, Kevin [2 ]
Gold, Michael [3 ]
Biffi, Mauro [4 ]
Ziacchi, Matteo [4 ]
Silverstein, Joshua [5 ]
Ramza, Brian [6 ]
Metzl, Mark [7 ]
Grubman, Eric [8 ]
Abben, Richard [9 ]
Varma, Niraj [1 ]
Tabbal, Ghiyath [9 ]
Jensen, Cory
Wouters, Griet
Ghosh, Subham
Vernooy, Kevin
机构
[1] Cleveland Clin, Heart & Vasc Inst, Dept Cardiovasc Med, Cleveland, OH USA
[2] Duke Univ, Div Cardiovasc Dis, Sect Cardiac Electrophysiol, Med Ctr, Durham, NC USA
[3] Med Univ South Carolina, Dept Med, Charleston, SC USA
[4] IRCCS Azienda Osped Univ Bologna, Inst Cardiol, Dept Expt Diagnost & Specialty Med, Bologna, Italy
[5] Mt Carmel Hlth Syst, Columbus, OH USA
[6] St Lukes Mid Amer Heart Inst, Div Cardiol, Kansas City, MO USA
[7] NorthShore Univ HealthSyst, Dept Med, Evanston, IL USA
[8] Yale Univ, Sect Cardiovasc Med, Sch Med, New Haven, CT USA
[9] Cardiovasc Inst South, Cardiac Intervent & Cardiac Arrythmia Ctr, Houma, LA USA
[10] Cleveland Clin, Heart Vasc & Thorac Inst, Sect Cardiac Electrophysiol, 9500 Euclid Ave-J2-2, Cleveland, OH 44195 USA
关键词
Cardiac resynchronization therapy; SDAT; Electrocar-diographic imaging; Heart failure; CARDIAC-RESYNCHRONIZATION THERAPY; BUNDLE-BRANCH BLOCK; HEART-FAILURE; MORBIDITY; MORTALITY;
D O I
10.1016/j.hrthm.2022.11.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Patients with ischemic cardiomyopathy, non-left bundle branch block, or QRS duration ,150 ms have a lower response rate to cardiac resynchronization therapy (CRT) than did other indicated patients. The ECG Belt system (EBS) is a novel sur -face mapping system designed to measure electrical dyssynchrony via the standard deviation of the activation times of the left ventricle. OBJECTIVES The objectives of this study were to evaluate the effi-cacy of the EBS in patients less likely to respond to CRT and to deter-mine whether EBS use in lead placement guidance and device programming was superior to standard CRT care.METHODS This was a prospective randomized trial of patients with heart failure and EBS-guided CRT implantation and programming vs standard CRT care. The primary end point was relative change in left ventricular end-systolic volume from baseline to 6 months postim-plantation.RESULTS A total of 408 patients from centers in Europe and North America were randomized. Although both patients with EBS and control patients had a mean improvement in left ventricular end-systolic volume, there was no significant difference in relative change from baseline (P 5 .26). While patients with a higher base-line standard deviation of the activation times derived greater left ventricular reverse remodeling, improvement in electrical dyssyn-chrony did not correlate with the extent of reverse remodeling.CONCLUSION The findings of the present study do not support EBS guided therapy for CRT management of heart failure with reduced ejection fraction.
引用
收藏
页码:537 / 544
页数:8
相关论文
共 50 条
  • [11] Long-term left ventricular lead stability during biventricular pacing
    Willis, J.
    Thomas, D.
    Webb, G.
    Penny, A.
    O'Callaghan, P.
    Anderson, R.
    Yousef, Z.
    HEART, 2007, 93 : A86 - A87
  • [12] Coronary sinus spasm during left ventricular lead implantation for biventricular pacing
    Russo, Vincenzo
    De Crescenzo, Llaria
    Arnmendola, Ernesto
    Cavallaro, Ciro
    Santangelo, Lucio
    Calabro, Raffaele
    EUROPACE, 2007, 9 (07): : 528 - 530
  • [13] Acute haemodynamic comparison of multisite and biventricular pacing with a quadripolar left ventricular lead
    Thibault, Bernard
    Dubuc, Marc
    Khairy, Paul
    Guerra, Peter G.
    Macle, Laurent
    Rivard, Lena
    Roy, Denis
    Talajic, Mario
    Karst, Edward
    Ryu, Kyungmoo
    Paiement, Patrice
    Farazi, Taraneh G.
    EUROPACE, 2013, 15 (07): : 984 - 991
  • [14] BIVENTRICULAR PACING IN PATIENTS WITH LEFT VENTRICULAR ASSIST DEVICES - IS LEFT VENTRICULAR PACING PROARRHYTHMIC??
    Choi, Andrew D.
    Fischer, Avi
    Anyanwu, Anelechi
    Pinney, Sean
    Adler, Eric
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [15] Prophylactic Epicardial Left Ventricular Lead Implantation for Biventricular Pacing During Operations
    Shan, Leonard
    Buratto, Edward
    Conaglen, Paul
    Davis, Philip
    Yii, Michael
    Nixon, Ian
    Newcomb, Andrew
    ANNALS OF THORACIC SURGERY, 2014, 97 (02): : 603 - 609
  • [16] Optimization of atrioventricular and interventricular pacing delay in biventricular pacing with different left ventricular electrode position
    Heinke, M.
    Dannberg, G.
    Solbrig, O.
    Querengasser, J.
    Kuehnert, H.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S230 - S232
  • [17] CEPHALIC VEIN CUTDOWN FOR LEFT VENTRICULAR LEAD PLACEMENT IN BIVENTRICULAR DEVICE UPGRADES
    Paydak, H.
    Pant, S.
    Siddique, K.
    Singh, D.
    CARDIOLOGY, 2014, 128 : 187 - 187
  • [18] Left Ventricular Pacing Lead Placement and Anatomy of Coronary Vein System
    Wang, D. M.
    Han, Y. L.
    Zang, H. Y.
    Yu, H. B.
    Wang, S. L.
    Jin, Q. M.
    Wang, Z. L.
    Geng, J. C.
    CARDIOLOGY, 2009, 114 : 31 - 31
  • [19] Is right ventricular outflow tract pacing an alternative to left ventricular/biventricular pacing?
    Riedlbauchová, L
    Kautzner, J
    Hatala, R
    Buckingham, TA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06): : 871 - 877
  • [20] Robotically assisted left ventricular epicardial lead implantation for biventricular pacing: The posterior approach
    Derose, JJ
    Belsley, S
    Swistel, DG
    Shaw, R
    Ashton, RC
    ANNALS OF THORACIC SURGERY, 2004, 77 (04): : 1472 - 1474