Hypoglycemia in children and young adults with cystic fibrosis during oral glucose tolerance testing vs. continuous glucose monitoring

被引:0
|
作者
Finn, Erin [1 ,5 ]
Severn, Cameron [2 ]
Pyle, Laura [2 ]
Garrish, Justin [3 ]
Vigers, Timothy [1 ]
Behn, Cecilia G. Diniz [1 ,3 ]
Zeitler, Philip S. [1 ]
Sagel, Scott D. [4 ]
Nadeau, Kristen J. [1 ]
Chan, Christine L. [1 ]
机构
[1] Univ Colorado, Childrens Hosp Colorado, Dept Pediat, Sect Pediat Endocrinol, Anschutz Med Campus, Aurora, CO USA
[2] Univ Colorado, Dept Biostat, Anschutz Med Campus, Aurora, CO USA
[3] Colorado Sch Mines, Dept Appl Math & Stat, Golden, CO USA
[4] Univ Colorado, Dept Pediat, Sect Pediat Pulmonol, Anschutz Med Campus, Aurora, CO USA
[5] Univ Colorado, Childrens Hosp Colorado, Anschutz Med Ctr, Aurora, CO 80045 USA
基金
美国国家科学基金会;
关键词
continuous glucose monitoring; cystic fibrosis; hypoglycemia; insulin sensitivity; oral glucose tolerance test; INSULIN SENSITIVITY; PANCREATIC-INSUFFICIENT; MINIMAL MODEL; SECRETION; PREVALENCE; CLEARANCE; THERAPY; IMPACT; CFTR;
D O I
10.1002/ppul.26533
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundHypoglycemia is common in people with cystic fibrosis (pwCF) during oral glucose tolerance tests (OGTTs) and in the free-living setting, yet its pathophysiology remains unclear. ObjectiveTo evaluate hypoglycemia in children and young adults with CF by OGTT and continuous glucose monitoring (CGM). MethodsA 3-h OGTT was performed in children and young adults with CF and healthy controls (HC). Individuals were classified as experiencing hypoglycemia on OGTT (glucose <70 mg/dL) or not. Insulin, C-peptide, glucose, glucagon, and incretins were measured. CGM was performed for 7 days in the free-living setting. Measures of insulin sensitivity, beta cell function accounting for insulin sensitivity, and insulin clearance were calculated. ResultsA total of 57 participants (40 CF and 17 HC) underwent assessment. Rates of hypoglycemia by OGTT were similar in pwCF (53%, 21/40) compared to HC (35%, 6/17), p = 0.23. PwCF compared to HC had higher A1c; on OGTT higher and later glucose peaks, later insulin peaks; and on CGM more glucose variability. CF Hypo+ versus CF Hypo- had higher lung function, higher insulin sensitivity, higher beta cell function accounting for insulin sensitivity, and decreased CGM variability. When comparing CF Hypo+ to HC Hypo+, although rates of hypoglycemia are similar, pwCF had blunted glucagon responses to hypoglycemia. OGTT hypoglycemia was not associated with CGM hypoglycemia in any group. ConclusionYouth with CF have increased insulin sensitivity and impaired glucagon response to hypoglycemia on OGTT. Hypoglycemia on OGTT did not associate with free-living hypoglycemia.
引用
收藏
页码:2495 / 2504
页数:10
相关论文
共 50 条
  • [41] Increased sputum lactate during oral glucose tolerance test in cystic fibrosis
    Jensen, Peter Ostrup
    Nielsen, Bibi Uhre
    Kolpen, Mette
    Pressler, Tacjana
    Faurholt-Jepsen, Daniel
    Mathiesen, Inger Hee Mabuza
    APMIS, 2022, 130 (08) : 535 - 539
  • [42] Elevation of 1-Hour Plasma Glucose During Oral Glucose Tolerance Testing Is Associated With Worse Pulmonary Function in Cystic Fibrosis
    Brodsky, Jill
    Dougherty, Shayne
    Makani, Ramkrishna
    Rubenstein, Ronald C.
    Kelly, Andrea
    DIABETES CARE, 2011, 34 (02) : 292 - 295
  • [43] Predictive Value of 1-Hour Glucose Elevations during Oral Glucose Tolerance Testing for Cystic Fibrosis-Related Diabetes
    Lorenz, Andrea N. N.
    Pyle, Laura
    Ha, Joon
    Sherman, Arthur
    Cree-Green, Melanie
    Sagel, Scott D. D.
    Nadeau, Kristen J. J.
    Chan, Christine L. L.
    PEDIATRIC DIABETES, 2023, 2023
  • [44] Continuous glucose monitoring in cystic fibrosis - A practical guide
    Chan, Christine L.
    Ode, Katie Larson
    Granados, Andrea
    Moheet, Amir
    Moran, Antoinette
    Hameed, Shihab
    JOURNAL OF CYSTIC FIBROSIS, 2019, 18 : S25 - S31
  • [45] Analysis of pancreatic response after oral glucose tolerance test in adults with cystic fibrosis
    Sanchez-Lopez, I.
    Sampedro-Nunez, M. A.
    Campos, S.
    Vicuna, A.
    Zelada, M.
    Maillo, M. A.
    Mosse, A.
    Ramos-Levi, A. M.
    Giron, R. M.
    Marazuela, M.
    Arranz, A.
    DIABETOLOGIA, 2014, 57 : S211 - S211
  • [46] Nocturnal saturation and glucose tolerance in children with cystic fibrosis
    Suratwala, Dharmeshkumar
    Chan, June S. H.
    Kelly, Andrea
    Meltzer, Lisa J.
    Gallagher, Paul R.
    Traylor, Joel
    Rubenstein, Ronald C.
    Marcus, Carole L.
    THORAX, 2011, 66 (07) : 574 - 578
  • [47] Association between postpartum continuous glucose monitoring and oral glucose tolerance testing for screening after GDM
    Drexler, Kathleen
    Boggess, Kim
    Battarbee, Ashley N.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 230 (01) : S96 - S97
  • [48] COMPARISON OF CONTINUOUS GLUCOSE MONITORING (CGM) AND ORAL GLUCOSE TOLERANCE TESTING (OGTT) IN THE DETECTION OF EARLY CFRD
    Dyce, P.
    Jones, G. H.
    Walshaw, M. J.
    PEDIATRIC PULMONOLOGY, 2014, 49 : 428 - 428
  • [49] Hemoglobin A1c Accurately Predicts Continuous Glucose Monitoring-Derived Average Glucose in Youth and Young Adults With Cystic Fibrosis
    Chan, Christine L.
    Hope, Emma
    Thurston, Jessica
    Vigers, Timothy
    Pyle, Laura
    Zeitler, Philip S.
    Nadeau, Kristen J.
    DIABETES CARE, 2018, 41 (07) : 1406 - 1413
  • [50] Continuous glucose monitoring (CGMS) enhances the detection of cystic fibrosis related diabetes (CFRD) in children with cystic fibrosis
    O'Riordan, S. M. P.
    Roche, E. F.
    George, S.
    Hoey, H. M. V.
    Costigan, C.
    DIABETOLOGIA, 2007, 50 : S84 - S85