Clinical application of spinal robot in cervical spine surgery: safety and accuracy of posterior pedicle screw placement in comparison with conventional freehand methods

被引:16
|
作者
Zhou, Lu-Ping [1 ,2 ]
Zhang, Ren-Jie [1 ,2 ]
Zhang, Wen-Kui [1 ,2 ]
Kang, Liang [1 ,2 ]
Li, Kai-Xuan [1 ,2 ]
Zhang, Hua-Qing [1 ,2 ]
Jia, Chong-Yu [1 ,2 ]
Zhang, Yin-Shun [1 ,2 ]
Shen, Cai-Liang [1 ,2 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthoped & Spine Surg, Hefei 230022, Anhui, Peoples R China
[2] Anhui Med Univ, Affiliated Hosp 1, Lab Spinal & Spinal Cord Injury Regenerat & Repair, Hefei 230022, Anhui, Peoples R China
关键词
Robot-assisted screw placement; Freehand; Pedicle screw accuracy; Posterior cervical; Cervical traumatic diseases; Risk factor; VERTEBRAL ARTERY INJURY; FACET JOINT VIOLATION; INTERNAL-FIXATION; ATLANTOAXIAL INSTABILITY; RISK; INSTRUMENTATION; NAVIGATION; ANOMALIES;
D O I
10.1007/s10143-023-02027-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The novel robot-assisted (RA) technique has been utilized increasingly to improve the accuracy of cervical pedicle screw placement. Although the clinical application of the RA technique has been investigated in several case series and comparative studies, the superiority and safety of RA over conventional freehand (FH) methods remain controversial. Meanwhile, the intra-pedicular accuracy of the two methods has not been compared for patients with cervical traumatic conditions. This study aimed to compare the rate and risk factors of intra-pedicular accuracy of RA versus the conventional FH approach for posterior pedicle screw placement in cervical traumatic diseases. A total of 52 patients with cervical traumatic diseases who received cervical screw placement using RA (26 patients) and FH (26 patients) techniques were retrospectively included. The primary outcome was the intra-pedicular accuracy of cervical pedicle screw placement according to the Gertzbin-Robbins scale. Secondary outcome parameters included surgical time, intraoperative blood loss, postoperative drainage, postoperative hospital stay, and complications. Moreover, the risk factors that possibly affected intra-pedicular accuracy were assessed using univariate analyses. Out of 52 screws inserted using the RA method, 43 screws (82.7%) were classified as grade A, with the remaining 7 (13.5%) and 2 (3.8%) screws classified as grades B and C. In the FH cohort, 60.8% of the 79 screws were graded A, with the remaining screws graded B (21, 26.6%), C (8, 10.1%), and D (2, 2.5%). The RA technique showed a significantly higher rate of optimal intra-pedicular accuracy than the FH method (P = 0.008), but there was no significant difference between the two groups in terms of clinically acceptable accuracy (P = 0.161). Besides, the RA technique showed remarkably longer surgery time, less postoperative drainage, shorter postoperative hospital stay, and equivalent intraoperative blood loss and complications than the FH technique. Furthermore, the univariate analyses showed that severe obliquity of the lateral atlantoaxial joint in the coronal plane (P = 0.003) and shorter width of the lateral mass at the inferior margin of the posterior arch (P = 0.014) were risk factors related to the inaccuracy of C1 screw placement. The diagnosis of HRVA (P < 0.001), severe obliquity of the lateral atlantoaxial joint in the coronal plane (P < 0.001), short pedicle width (P < 0.001), and short pedicle height (P < 0.001) were risk factors related to the inaccuracy of C2 screw placement. RA cervical pedicle screw placement was associated with a higher rate of optimal intra-pedicular accuracy to the FH technique for patients with cervical traumatic conditions. The severe obliquity of the lateral atlantoaxial joint in the coronal plane independently contributed to high rates of the inaccuracy of C1 and C2 screw placements. RA pedicle screw placement is safe and useful for cervical traumatic surgery.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Clinical application of spinal robot in cervical spine surgery: safety and accuracy of posterior pedicle screw placement in comparison with conventional freehand methods
    Lu-Ping Zhou
    Ren-Jie Zhang
    Wen-Kui Zhang
    Liang Kang
    Kai-Xuan Li
    Hua-Qing Zhang
    Chong-Yu Jia
    Yin-Shun Zhang
    Cai-Liang Shen
    Neurosurgical Review, 46
  • [2] The Safety and Accuracy of Freehand Pedicle Screw Placement in the Subaxial Cervical Spine A Series of 45 Consecutive Patients
    Park, Jin Hoon
    Jeon, Sang Ryong
    Roh, Sung Woo
    Kim, Jeoung Hee
    Rhim, Seung Chul
    SPINE, 2014, 39 (04) : 280 - 285
  • [3] Comparison of Accuracy and Clinical Outcomes of Robot-Assisted Versus Fluoroscopy-Guided Pedicle Screw Placement in Posterior Cervical Surgery
    Su, Xin-Jin
    Lv, Zhen-Dong
    Chen, Zhi
    Wang, Kun
    Zhu, Chao
    Chen, Hao
    Han, Ying-Chao
    Song, Qing-Xin
    Lao, Li-Feng
    Zhang, Yu-Hui
    Li, Quan
    Shen, Hong-Xing
    GLOBAL SPINE JOURNAL, 2022, 12 (04) : 620 - 626
  • [4] Comparison of robot-assisted and freehand pedicle screw placement for lumbar revision surgery
    Zhang, Jia-Nan
    Fan, Yong
    He, Xin
    Liu, Tuan-Jiang
    Hao, Ding-Jun
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (06) : 1531 - 1538
  • [5] Comparison of robot-assisted and freehand pedicle screw placement for lumbar revision surgery
    Jia-Nan Zhang
    Yong Fan
    Xin He
    Tuan-Jiang Liu
    Ding-Jun Hao
    International Orthopaedics, 2021, 45 : 1531 - 1538
  • [6] Robotics in Cervical Spine Surgery: Feasibility and Safety of Posterior Screw Placement
    Zhou, Lu-Ping
    Zhang, Zhi-Gang
    Li, Dui
    Fang, Shu
    Sheng, Rui
    Zhang, Ren-Jie
    Shen, Cai-Liang
    NEUROSPINE, 2023, 20 (01) : 329 - +
  • [7] Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials
    Peng, Yu-Ning
    Tsai, Li-Cheng
    Hsu, Horng-Chaung
    Kao, Chia-Hung
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (13)
  • [8] Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review
    Aoude, Ahmed A.
    Fortin, Maryse
    Figueiredo, Rainer
    Jarzem, Peter
    Ouellet, Jean
    Weber, Michael H.
    EUROPEAN SPINE JOURNAL, 2015, 24 (05) : 990 - 1004
  • [9] Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review
    Ahmed A. Aoude
    Maryse Fortin
    Rainer Figueiredo
    Peter Jarzem
    Jean Ouellet
    Michael H. Weber
    European Spine Journal, 2015, 24 : 990 - 1004
  • [10] Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis
    Liu, Hao
    Chen, Weikai
    Wang, Zongyi
    Lin, Jun
    Meng, Bin
    Yang, Huilin
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (12) : 2273 - 2281