摘要
With the development of new energy technologies, dual-source trolleybuses are widely used in public transportation systems. A synergistic schedule can further improve the service quality of vehicles and optimize the passenger travel experience. This study investigated the synchronized scheduling of dual-source trolleybus networks to reduce the transfer time of passengers and the fleet size problem to reduce the operating cost of enterprises. A bi-objective mixed-integer linear programming model was developed to maximize the total synchronizations and minimize the total fleet size of dual-source trolleybus lines. A two-stage algorithm was designed to obtain multiple sets of Pareto effective solutions. Meanwhile, to demonstrate the effectiveness of the proposed method, the results of numerical examples solved by the two-stage algorithm were compared with those of a genetic algorithm (GA) and a nondominated sorting genetic algorithm (NSGA-II). A real-world case study based on the Beijing dual-source trolleybus network was studied to validate the proposed model. The results show that the model can obtain synchronized schedules. The optimization of the number of synchronizations and fleet size is obvious. The model and algorithm can be applied to a large dual-source trolleybus network.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Noise Reduction in Dual-Source CT Scanning
    Petersilka, M.
    Krauss, B.
    Stierstorfer, K.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [32] Dual-source CT for chest pain assessment
    Johnson, Thorsten R. C.
    Nikolaou, Konstantin
    Becker, Alexander
    Leber, Alexander W.
    Rist, Carsten
    Wintersperger, Bernd J.
    Reiser, Maximilian F.
    Becker, Christoph R.
    EUROPEAN RADIOLOGY, 2008, 18 (04) : 773 - 780
  • [33] Application of a dual-source Weissenberg type diffractometer
    Borrmann, H.
    Zhang, H.
    Prots, Yu.
    Schmidt, M.
    Schnelle, W.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2004, 60 : S114 - S114
  • [34] STATIONARY PREMIXED FLAMES IN A DUAL-SOURCE SYSTEM
    BREWSTER, ME
    COMBUSTION AND FLAME, 1992, 91 (01) : 99 - 105
  • [35] TOMAHAWK MOVES TOWARD DUAL-SOURCE PRODUCTION
    KOZICHAROW, E
    AVIATION WEEK & SPACE TECHNOLOGY, 1984, 120 (06): : 56 - &
  • [36] Dual-source CT for chest pain assessment
    Thorsten R. C. Johnson
    Konstantin Nikolaou
    Alexander Becker
    Alexander W. Leber
    Carsten Rist
    Bernd J. Wintersperger
    Maximilian F. Reiser
    Christoph R. Becker
    European Radiology, 2008, 18 : 773 - 780
  • [37] Fundamentals of Dual-Source Heating Systems.
    Kalischer, Peter
    Elektrowaerme International, 1975, 33 (A4):
  • [38] Particle Swarm Optimization for energy management fuzzy controller design in dual-source electric vehicle
    Zhang Chenghui
    Shi Qingsheng
    Cui Naxin
    Li Wuhua
    2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 1405 - 1410
  • [39] Design and Optimization of a Dual-Source Triple Gate FET Using Electrostatically Induced Reconfigurable Property
    Kundu, Antara
    Saha, Priyanka
    Sarkar, Subir Kumar
    IETE TECHNICAL REVIEW, 2022, 39 (06) : 1254 - 1264
  • [40] Reproducibility of coronary artery calcium quantification on dual-source CT and dual-source photon-counting CT: a dynamic phantom study
    van der Werf, Niels R.
    Booij, Ronald
    Greuter, Marcel J. W.
    Bos, Daniel
    van der Lugt, A.
    Budde, R. P. J.
    van Straten, Marcel
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (07): : 1613 - 1619