Multicenter Experience with Good Manufacturing Practice Production of [11C]PiB for Amyloid Positron Emission Tomography Imaging

被引:0
|
作者
Andersen, Anders Bruhn Arndal [1 ]
Lehel, Szabolcs [2 ]
Grove, Ebbe Klit [3 ,4 ]
Langkjaer, Niels [5 ]
Fuglo, Dan [1 ]
Huynh, Tri Hien Viet [1 ]
机构
[1] Copenhagen Univ Hosp, Dept Nucl Med, Borgmester Ib Juuls Vej 1, DK-2730 Herlev, Denmark
[2] Copenhagen Univ Hosp Rigshospitalet, Dept Clin Physiol Nucl Med & PET, DK-2100 Copenhagen, Denmark
[3] Aarhus Univ Hosp, Dept Nucl Med, DK-8200 Aarhus, Denmark
[4] Aarhus Univ Hosp, PET Ctr, DK-8200 Aarhus, Denmark
[5] Odense Univ Hosp, Dept Nucl Med, DK-5000 Odense, Denmark
关键词
C-11]PiB; radiosynthesis; PET/CT imaging; GMP production; Alzheimer's disease; ALZHEIMERS-DISEASE; DIAGNOSTIC-ACCURACY; RADIOSYNTHESIS;
D O I
10.3390/ph17020217
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Alzheimer's disease (AD) is a neurodegenerative disorder with increasing global prevalence and accounts for over half of all dementia cases. Early diagnosis is paramount for not only the management of the disease, but also for the development of new AD treatments. The current golden standard for diagnosis is performed by positron emission tomography (PET) scans with the tracer [C-11]Pittsburg Compound B ([C-11]PiB), which targets amyloid beta protein (A beta) that builds up as plaques in the brain of AD patients. The increasing demand for AD diagnostics is in turn expected to drive an increase in [C-11]PiB-PET scans and the setup of new [C-11]PiB production lines at PET centers globally. Here, we present the [C-11]PiB production setups, experiences, and use from four Danish PET facilities and discuss the challenges and potential pitfalls of [C-11]PiB production. We report on the [C-11]PiB production performed with the 6-OH-BTA-0 precursor dissolved in either dry acetone or 2-butanone and by using either [C-11]CO2 or [C-11]CH4 as C-11- precursors on three different commercial synthesis modules: TracerLab FX C Pro, ScanSys, or TracerMaker. It was found that the [C-11]CO2 method gives the highest radioactive yield (1.5 to 3.2 GBq vs. 0.8 +/- 0.3 GBq), while the highest molar activity (98.0 +/- 61.4 GBq/mu mol vs. 21.2 to 95.6 GBq/mu mol) was achieved using [C-11]CH4. [C-11]PiB production with [C-11]CO2 on a TracerLab FX C Pro offered the most desirable results, with the highest yield of 3.17 +/- 1.20 GBq and good molar activity of 95.6 +/- 44.2 GBq/mu mol. Moreover, all reported methods produced [C-11]PiB in quantities suitable for clinical applications, thus providing a foundation for other PET facilities seeking to establish their own [C-11]PiB production.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A novel 11C-labeled thymidine analog, [11C]AZT, for tumor imaging by positron emission tomography
    Tahara, Tsuyoshi
    Zhang, Zhouen
    Ohno, Masahiro
    Hirao, Yukako
    Hosaka, Nami
    Doi, Hisashi
    Suzuki, Masaaki
    Onoe, Hirotaka
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [22] [11C]acetate positron emission tomography in prostate carcinoma -: New perspectives in metabolic imaging
    Hautzel, H
    Müller-Mattheis, V
    Herzog, H
    Roden, W
    Coenen, HH
    Ackermann, R
    Müller-Gärtner, HW
    Krause, BJ
    UROLOGE A, 2002, 41 (06): : 569 - 576
  • [23] [11C]Paraoxon: Radiosynthesis, Biodistribution and In Vivo Positron Emission Tomography (PET) Imaging in Rat
    Hayes, Thomas R.
    Chao, Chih-Kai
    Blecha, Joseph E.
    Huynh, Tony L.
    VanBrocklin, Henry F.
    Zinn, Kurt R.
    Gerdes, John M.
    Thompson, Charles M.
    JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2024, 388 (02): : 333 - 346
  • [24] An updated synthesis of [11C]carfentanil for positron emission tomography (PET) imaging of the μ-opioid receptor
    Blecha, Joseph E.
    Henderson, Bradford D.
    Hockley, Brian G.
    VanBrocklin, Henry F.
    Zubieta, Jon-Kar
    DaSilva, Alexandre F.
    Kilbourn, Michael R.
    Koeppe, Robert A.
    Scott, Peter J. H.
    Shao, Xia
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2017, 60 (08): : 375 - 380
  • [25] A novel 11C-labeled thymidine analog, [11C] AZT, for tumor imaging by positron emission tomography
    Tahara, Tsuyoshi
    Zhang, Zhouen
    Ohno, Masahiro
    Hirao, Yukako
    Hosaka, Nami
    Doi, Hisashi
    Suzuki, Masaaki
    Onoe, Hirotaka
    EJNMMI RESEARCH, 2015, 5
  • [26] A novel 11C-labeled thymidine analog, [11C]AZT, for tumor imaging by positron emission tomography
    Tsuyoshi Tahara
    Zhouen Zhang
    Masahiro Ohno
    Yukako Hirao
    Nami Hosaka
    Hisashi Doi
    Masaaki Suzuki
    Hirotaka Onoe
    EJNMMI Research, 5
  • [27] Improved synthesis and application of [11C]benzyl iodide in positron emission tomography radiotracer production
    Pekosak, Aleksandra
    Filp, Ulrike
    Rotteveel, Lonneke
    Poot, Alex J.
    Windhorst, Albert D.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2015, 58 (08): : 342 - 348
  • [28] Imaging of Vascular Inflammation With [11C]-PK11195 and Positron Emission Tomography/Computed Tomography Angiography
    Pugliese, Francesca
    Gaemperli, Oliver
    Kinderlerer, Anne R.
    Lamare, Frederic
    Shalhoub, Joseph
    Davies, Alun Huw
    Rimoldi, Ornella E.
    Mason, Justin C.
    Camici, Paolo G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (08) : 653 - 661
  • [29] Synthesis of Endogenous Compounds Labeled with 11C for Positron Emission Tomography
    Kilian, K.
    Pekal, A.
    ACTA PHYSICA POLONICA A, 2015, 127 (05) : 1475 - 1478
  • [30] Positron emission tomography with [11C]-PIB: a clinically relevant tool for voxel-wise myelin quantification in multiple sclerosis
    Bodini, B.
    Veronese, M.
    Garcia-Lorenzo, D.
    Freeman, L.
    Papeix, C.
    Zalc, B.
    Lehericy, S.
    Lubetzki, C.
    Bottlaender, M.
    Stankoff, B.
    Turkheimer, F.
    MULTIPLE SCLEROSIS JOURNAL, 2013, 19 (11) : 174 - 175