Voltammetric Determination of Metrafenone Using an Iridium Oxide Nanoparticle - Ionic Liquid Nanocomposite Modified Glassy Carbon Electrode

被引:2
|
作者
Celik, Murat [1 ,2 ]
Bozal-Palabiyik, Burcin [1 ]
Kanbes Dindar, Cigdem [1 ]
Uslu, Bengi [1 ,3 ]
机构
[1] Ankara Univ, Fac Pharm, Dept Analyt Chem, Ankara, Turkiye
[2] Ankara Univ, Grad Sch Hlth Sci, Ankara, Turkiye
[3] Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06565 Ankara, Turkiye
关键词
Adsorptive stripping differential pulse voltammetry (DPV); electrochemical analysis; ionic liquid; iridium oxide nanoparticles; metrafenone; nanosensor; PHARMACEUTICALS; PESTICIDES; NANOSENSOR; SENSOR;
D O I
10.1080/00032719.2024.2318653
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the first sensitive voltammetric nanosensor was developed for the determination of metrafenone. For this purpose, iridium oxide nanoparticles (IrOxNPs) were synthesized, and a nanocomposite was formed on the glassy carbon electrode with IrOxNPs and an ionic liquid (IL). The influence of pH on the metrafenone response was examined using phosphate and Britton-Robinson buffers as a function of pH. The influence of scan rate on the response to metrafenone was investigated in pH 7.0 phosphate buffer where the highest peak current was obtained and the peak shape was good. It was concluded that the oxidation occurred by the adsorption and diffusion mechanisms. According to cyclic voltammetry measurements for metrofenone, a single irreversible anodic peak was observed in all buffer solutions. Using the relationship between the peak potential and the logarithm of the scan rate, the electron number for the oxidation process was determined to be 2. Using adsorptive stripping differential pulse voltammetry, the detection limits for standard and the serum samples were 0.08 mg/L and 0.07 mg/L, respectively, and the calibration curve was linear up to 1.4 mg/L. The developed nanosensor was also employed to analyze to commercial preparations and good recovery values were obtained.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Voltammetric Determination of Dopamine Using Glassy Carbon Electrode Modified with ZnO/Al2O3 Nanocomposite
    Ganjali, Mohammad Reza
    Beitollahi, Hadi
    Zaimbashi, Reza
    Tajik, Somayeh
    Rezapour, Morteza
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (03): : 2519 - 2529
  • [42] Sensitive Voltammetric Detection of Indomethacin Using TiO2 Nanoparticle Modified Carbon Ionic Liquid Electrode
    Baezzat, Mohammad Reza
    Banavand, Fatemeh
    Hakkani, Sedigheh Kamran
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2020, 7 (01): : 89 - 98
  • [43] Voltammetric Determination of Tryptophan Using a Carbon Paste Electrode Modified with Magnesium Core Shell Nanocomposite and Ionic Liquids
    Mohammadi, Sayed Zia
    Beitollahi, Hadi
    Hassanzadeh, Mohsen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2018, 5 (01): : 55 - 65
  • [44] Determination of 4-aminophenylarsonic acid using a glassy carbon electrode modified with an ionic liquid and carbon nanohorns
    Hong Dai
    Lingshan Gong
    Shuangyan Lu
    Qingrong Zhang
    Yilin Li
    Shupei Zhang
    Guifang Xu
    Xiuhua Li
    Yanyu Lin
    Guonan Chen
    Microchimica Acta, 2015, 182 : 1247 - 1254
  • [45] Determination of 4-aminophenylarsonic acid using a glassy carbon electrode modified with an ionic liquid and carbon nanohorns
    Dai, Hong
    Gong, Lingshan
    Lu, Shuangyan
    Zhang, Qingrong
    Li, Yilin
    Zhang, Shupei
    Xu, Guifang
    Li, Xiuhua
    Lin, Yanyu
    Chen, Guonan
    MICROCHIMICA ACTA, 2015, 182 (7-8) : 1247 - 1254
  • [46] Simultaneous voltammetric determination of tramadol and acetaminophen using carbon nanoparticles modified glassy carbon electrode
    Ghorbani-Bidkorbeh, Fatemeh
    Shahrokhian, Saeed
    Mohammadi, Ali
    Dinarvand, Rassoul
    ELECTROCHIMICA ACTA, 2010, 55 (08) : 2752 - 2759
  • [47] Voltammetric Determination of Tetracycline by Using Multi-Wall Carbon Nanotube - Ionic Liquid Film Coated Glassy Carbon Electrode
    Guo, Gaiping
    Zhao, Faqiong
    Xiao, Fei
    Zeng, Baizhao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (09): : 1365 - 1372
  • [48] Voltammetric Determination of Sulfonamides with a Modified Glassy Carbon Electrode Using Carboxyl Multiwalled Carbon Nanotubes
    He, Bao-Shan
    Chen, Wen-Bo
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (12) : 2216 - 2225
  • [49] Voltammetric Determination of Cefuroxime Axetil in Pharmaceuticals Using Graphene Oxide Modified Glassy Carbon Electrode and Hanging Mercury Drop Electrode
    Kablan, Sevilay Erdogan
    Ozaltin, Nuran
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2019, 55 (04) : 305 - 313
  • [50] Voltammetric Determination of Cefuroxime Axetil in Pharmaceuticals Using Graphene Oxide Modified Glassy Carbon Electrode and Hanging Mercury Drop Electrode
    Sevilay Erdoğan Kablan
    Nuran Özaltın
    Russian Journal of Electrochemistry, 2019, 55 : 305 - 313