Improved accuracy of the biodistribution and internal radiation dosimetry of 13N-ammonia using a total-body PET/CT scanner

被引:5
|
作者
Yu, Xiaofeng [1 ]
Sun, Hongyan [2 ]
Xu, Lian [1 ]
Han, Yuan [1 ]
Wang, Cheng [1 ]
Li, Lianghua [1 ]
Ng, YeeLing [2 ]
Shi, Fuxiao [2 ]
Qiu, Ju [1 ]
Huang, Gang [1 ]
Zhou, Yun [2 ]
Chen, Yumei [1 ,3 ]
Liu, Jianjun [1 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Renji Hosp, Sch Med, Dept Nucl Med, Shanghai, Peoples R China
[2] United Imaging Healthcare, Cent Res Inst, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Renji Hosp, Sch Med, Dept Nucl Med, 160 Pujian Rd, Shanghai 200127, Peoples R China
基金
中国国家自然科学基金;
关键词
13N-ammonia; biodistribution; internal radiation dose; total-body PET; CT; uEXPLORER;
D O I
10.1002/mp.16450
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundConventional short-axis PET typically utilizes multi-bed multi-pass acquisition to produce quantitative whole-body dynamic images and cannot record all the uptake information simultaneously, resulting in errors when fitting the time-activity curves (TACs) and calculating radiation doses. PurposeThe aim of this study is to evaluate the N-13-ammonia biodistribution and the internal radiation doses using a 194 cm long total-body PET/CT scanner (uEXPLORER), and make a comparison with the previous short-axis PET results. MethodsTen subjects (age 40-74 years) received N-13-NH3 injection (418.1-670.81 MBq) and were under a dynamic scan for about 60 min with using a 3-dimensional whole-body protocol. ROIs were drawn visually on 11 major organs (brain, thyroid, gallbladder, heart wall, kidneys, liver, pancreas, spleen, lungs, bone marrow, and urinary bladder content) for each subject. TACs were generated using Pmod and the absorbed radiation doses were calculated using Olinda 2.2. To compare with the conventional PET/CT, five points were sampled on uEXPLORER's TACs to mimic the result of a short-axis PET/CT (15 cm axial FOV, consisted of 9 or 10 bed positions). Then the TACs were obtained using the multi-exponential fitting method, and the residence time and radiation dose were also calculated and compared with uEXPLORER. ResultsThe highest absorbed organ doses were the pancreas, thyroid, spleen, heart wall, and kidneys for the male. For the female, the first five highest absorbed organ dose coefficients were the pancreas, heart wall, spleen, lungs, and kidneys. The lowest absorbed dose was found in red marrow both for male and female. The simulated short-axis PET can fit TACs well for the gradually-changed uptake organs but typically underestimated for the rapid-uptake organs during the first-10 min, resulting in errors in the calculated radiation dose. ConclusionuEXPLORER PET/CT can measure N-13-ammonia's TACs simultaneously in all organs of the whole body, which can provide more accurate biodistribution and radiation dose estimation compared with the conventional short-axis scanners.
引用
收藏
页码:5865 / 5874
页数:10
相关论文
共 50 条
  • [1] Quantitative accuracy in total-body imaging using the uEXPLORER PET/CT scanner
    Leung, Edwin K.
    Berg, Eric
    Omidvari, Negar
    Spencer, Benjamin A.
    Li, Elizabeth
    Abdelhafez, Yasser G.
    Schmall, Jeffrey P.
    Liu, Weiping
    He, Liuchun
    Tang, Songsong
    Liu, Yilin
    Dong, Yun
    Jones, Terry
    Cherry, Simon R.
    Badawi, Ramsey D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (20):
  • [2] Biodistribution and estimation of radiation-absorbed doses in humans for 13N-ammonia PET
    Yi, Chang
    Yu, Donglan
    Shi, Xinchong
    He, Qiao
    Zhang, Xuezhen
    Zhang, Xiangsong
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (09) : 810 - 815
  • [3] Biodistribution and estimation of radiation-absorbed doses in humans for 13N-ammonia PET
    Chang Yi
    Donglan Yu
    Xinchong Shi
    Qiao He
    Xuezhen Zhang
    Xiangsong Zhang
    Annals of Nuclear Medicine, 2015, 29 : 810 - 815
  • [4] Pilot study on 11C-CFT dynamic imaging using total-body PET/CT: biodistribution and radiation dosimetry in Parkinson's disease
    Xin, Mei
    Li, Lianghua
    Wang, Cheng
    Shao, Hongda
    Liu, Jianjun
    Zhang, Chenpeng
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [5] Performance and application of the total-body PET/CT scanner: a literature review
    Sun, Yuanyuan
    Cheng, Zhaoping
    Qiu, Jianfeng
    Lu, Weizhao
    EJNMMI RESEARCH, 2024, 14 (01)
  • [6] Feasibility of in vivo small animal imaging using a clinical total-body PET/CT scanner
    Mannheim, J.
    Lan, W.
    Krueger, M. A.
    la Fougere, C.
    Schmidt, F. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S37 - S37
  • [7] 13N-ammonia myocardial perfusion imaging with a PET/CT scanner: impact on clinical decision making and cost-effectiveness
    Patrick T. Siegrist
    Lars Husmann
    Martina Knabenhans
    Oliver Gaemperli
    Ines Valenta
    Tobias Hoefflinghaus
    Hans Scheffel
    Paul Stolzmann
    Hatem Alkadhi
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 889 - 895
  • [8] Effects of misalignment between CT attenuation and emission PET images in 13N-ammonia myocardial PET/CT
    Tomita, Yoya
    Ichikawa, Yasutaka
    Ishida, Masaki
    Takeda, Kan
    Maeda, Hisato
    Sakuma, Hajime
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [9] Biodistribution and radiation dosimetry of multiple tracers on total-body positron emission tomography/computed tomography
    Li, Lianghua
    Wan, Liangrong
    Zhao, Haitao
    Wang, Cheng
    Wei, Weijun
    Liu, Jianjun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (08) : 5182 - 5194
  • [10] 13N-ammonia myocardial perfusion imaging with a PET/CT scanner:: impact on clinical decision making and cost-effectiveness
    Siegrist, Patrick T.
    Husmann, Lars
    Knabenhans, Martina
    Gaemperli, Oliver
    Valenta, Ines
    Hoefflinghaus, Tobias
    Scheffel, Hans
    Stolzmann, Paul
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (05) : 889 - 895