Enhancing Seismic Resilience of Existing Reinforced Concrete Building Using Non-Linear Viscous Dampers: A Comparative Study

被引:9
|
作者
Riaz, Raja Dilawar [1 ]
Malik, Umair Jalil [1 ]
Shah, Mati Ullah [1 ]
Usman, Muhammad [1 ]
Najam, Fawad Ahmed [1 ,2 ]
机构
[1] Natl Univ Sci & Technol NUST, Sch Civil & Environm Engn SCEE, H 12 Sect Islamabad, Islamabad 44000, Pakistan
[2] Univ British Columbia, Fac Appl Sci, Sch Engn, Kelowna, BC V1V 1V7, Canada
关键词
fluid viscous damper; energy dissipation; structural dynamics; non-linear analysis; retrofitting; seismic resilience; ENERGY-DISSIPATION; RETROFIT; DESIGN; STRATEGIES; BEHAVIOR; PHYSICS; DEMAND;
D O I
10.3390/act12040175
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
After the catastrophic destruction of the October 2005 Kashmir earthquake, the first building code of Pakistan was developed in 2007. The sole purpose of the building code of Pakistan (BCP) was to incorporate advancements in earthquake-resistant design to fortify structures and ensure the safety of citizens against future seismic events. After 2007, the BCP was not revised till 2021 to include the changes over time. However, the recently updated version of BCP 2021 highlights that the seismicity of many regions in Pakistan is high, which is not truly reflected in the BCP 2007. Therefore, the advancements in earthquake-resistant design due to the growing concerns about the potential risks of seismicity in the region have been incorporated into the updated version of the BCP. However, there are concerns among researchers that many structures designed on the 2007 code may need seismic fortification. Therefore, the current study focuses on the seismic fortification of existing systems that were developed using previous codes. Non-linear viscous fluid dampers are used to improve the seismic resilience of existing structures. This study compares the seismic performance of an existing reinforced concrete building with and without non-linear viscous dampers and subjected to a non-linear dynamic analysis. The performance of the building is evaluated in terms of story displacement, story drift, story acceleration, and energy dissipation mechanisms. Adding the non-linear fluid viscous dampers in the structure caused a decrease in the inter-story drift by around 31.16% and the roof displacement was reduced by around 36.58%. In addition to that, in a controlled structure, more than 70% of energy was dissipated by the fluid viscous dampers. These results indicate that adding the non-linear fluid viscous dampers to the existing structure significantly improved the vibration performance of the system against undesirous vibrations. The outcomes of this study also provide a very detailed insight into the usage of non-linear viscous dampers for improving the seismic performance of existing buildings and can be used to develop effective strategies to mitigate the impact of seismic events on already built structures.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Topology optimization of non-linear viscous dampers for energy-dissipating structures subjected to non-stationary random seismic excitation
    Cheng Su
    Jianhua Xian
    Structural and Multidisciplinary Optimization, 2022, 65
  • [22] Topology optimization of non-linear viscous dampers for energy-dissipating structures subjected to non-stationary random seismic excitation
    Su, Cheng
    Xian, Jianhua
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2022, 65 (07)
  • [23] Non-linear dynamic response of a reinforced concrete secondary containment shell subjected to seismic load
    Manjuprasad, M
    Gopalakrishnan, S
    Rao, TVSRA
    ENGINEERING STRUCTURES, 2001, 23 (05) : 397 - 406
  • [24] Influence of the Plan Structural Symmetry on the Non-Linear Seismic Response of Framed Reinforced Concrete Buildings
    Vielma-Quintero, Juan Carlos
    Diaz-Segura, Edgar Giovanny
    Vielma, Juan Carlos
    SYMMETRY-BASEL, 2024, 16 (03):
  • [25] Seismic assessment of mixed masonry-reinforced concrete buildings by non-linear static analyses
    Cattari, S.
    Lagomarsino, S.
    EARTHQUAKES AND STRUCTURES, 2013, 4 (03) : 241 - 264
  • [26] Comparative study on the effectiveness of fluid viscous dampers and base isolation: an approach toward enhancing seismic performance of composite structures
    Thakur, Ranbeer
    Tiwary, Aditya Kumar
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2023, 8 (10)
  • [27] Comparative study on the effectiveness of fluid viscous dampers and base isolation: an approach toward enhancing seismic performance of composite structures
    Ranbeer Thakur
    Aditya Kumar Tiwary
    Innovative Infrastructure Solutions, 2023, 8
  • [28] 2D-Linear static and non-linear dynamic progressive collapse analysis of reinforced concrete building
    Gowtham, S.
    Prakash, M.
    Parthasarathi, N.
    Satyanarayanan, K. S.
    Thamilarasu, V.
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (02) : 8775 - 8783
  • [29] Tall buildings seismic behavior comparative study by increasing the concrete mechanical strength through non-linear static analysis and seismic performance
    Lopez-De-La-Cruz, F.
    Choncen-Arboleda, A.
    Moreno-Sanchez, J.
    6TH INTERNATIONAL CONFERENCE ON MECHANICAL, MATERIALS AND MANUFACTURING, 2019, 689
  • [30] Study on non-linear damping ratio response spectrum of reinforced concrete buildings
    He, Yibin
    Fan, Haitao
    Zhou, Xuhong
    Li, Yan
    Xiao, Alin
    Huang, Pin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2010, 31 (03): : 38 - 44