Seismic Behavior of Lap Splice Reinforced Concrete Frames with Light-Steel-Framed Walls and Different Anchorage Details

被引:1
|
作者
Balik, Fatih Suleyman [1 ]
Bahadir, Fatih [1 ]
Kamanli, Mehmet [2 ]
机构
[1] Necmettin Erbakan Univ, Eregli High Vocat Sch, Konya, Turkey
[2] Konya Tech Univ, Civil Engn Dept, Konya, Turkey
关键词
reinforced concrete frame; light-steel-framed infill walls; reversed-cyclic lateral loading; load-carrying-capacity; energy-disspation; initial stiffness; EXTERNAL MESH REINFORCEMENT; INFILL WALLS; RC FRAMES; SHEAR WALL; PERFORMANCE; MORTAR;
D O I
10.1080/10168664.2022.2073941
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, the seismic behavior of light-steel-framed, infill-walled, lap splice reinforced concrete (RC) frames covered with steel sheets was experimentally investigated. A total of four RC frames to 1/5 scale, single-span and having two stories were produced for the experiments. One of the frames was a double-skeleton light-steel-framed infill-walled specimen having an anchorage spacing of 130 mm in the columns and the connection of the steel sheet plates to the profiles was made using self-drilling screws, and the other one had a 65 mm anchorage spacing in the columns and the connection of the steel sheet plates to the profiles was made using bolts. Two reference specimens were used. These are the bare frame and the aerated concrete infill wall frame. Tests of these specimens were carried out under constant axial load and reversed-cyclic lateral load. As a result of this study, it was observed that double-skeleton systems contributed positively to the lateral load-carrying capacity, energy-dissipation and initial stiffness of the RC frame. Additionally, it was concluded that the strength and energy-dissipation feature of the specimen could be increased by reducing the anchorage spacing in light-steel-framed wall systems and by attaching the steel sheet plate to the profiles using bolts.
引用
收藏
页码:488 / 497
页数:10
相关论文
共 50 条
  • [41] Experiments and FE Modeling on the Seismic Behavior of Partially Precast Steel-Reinforced Concrete Squat Walls
    Yu, Yunlong
    Liu, Yuntao
    Tan, Bin
    Liu, Yaping
    Xue, Yicong
    BUILDINGS, 2024, 14 (11)
  • [42] Seismic Behavior and Drift Limits of Different Performance Levels for Steel Reinforced Concrete Columns
    Guo, Zixiong
    Liu, Yang
    Huang, Qunxian
    ADVANCED SCIENCE LETTERS, 2011, 4 (8-10) : 3018 - 3022
  • [43] Seismic Behavior of Concrete-Filled Circular Steel Tubular Column-Reinforced Concrete Beam Frames with Recycled Aggregate Concrete
    Chen, Zongping
    Zhou, Ji
    Li, Zhibin
    Wang, Xinyue
    Zhou, Xingyu
    APPLIED SCIENCES-BASEL, 2020, 10 (07):
  • [44] THE EFFECT OF AXIAL COMPRESSION RATIO ON SEISMIC BEHAVIOR OF INFILLED REINFORCED CONCRETE FRAMES WITH PROFILED STEEL SHEET BRACING
    Feng Ningning
    Wu Changsheng
    Ma Junyue
    Mao Xiaotian
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2018, 27 (03):
  • [45] Assessment for behavior of axially loaded reinforced concrete columns strengthened by different patterns of steel-framed jacket
    Shhatha, Muaid Adnan
    Mahdi, Waseem H. H.
    Alalikhan, Ahmed A. A.
    OPEN ENGINEERING, 2023, 13 (01):
  • [46] Experimental study on seismic behavior of a reinforced concrete column-steel beam frame interior joint with various details
    Men, Jinjie
    Guo, Zhifeng
    Shi, Qingxuan
    Zhou, Qi
    Zhang, Xinghu
    Hu, Jun
    Xiong, Liquan
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2014, 35 (08): : 72 - 79
  • [47] Influence of Axial Load Ratio on the Seismic Behavior of Steel Fiber-Reinforced Concrete Composite Shear Walls
    Zhang, Hongmei
    Zhang, Ying
    Lu, Xilin
    Duan, Yuanfeng
    Zhang, Hanshu
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (01)
  • [48] Test and analysis on seismic behavior of low-rise steel-encased reinforced concrete shear walls
    Liu, Hang
    Lan, Zongjian
    Pang, Tonghe
    Meng, Zhaopei
    Liu, Ailian
    Wen, Feng
    Gongye Jianzhu/Industrial Construction, 1997, 27 (05): : 32 - 36
  • [49] Seismic behavior of concrete-filled double-skin steel tube/moment-resisting frames with beam-only-connected precast reinforced concrete shear walls
    Hu, Yi
    Zhao, Junhai
    Zhang, Dongfang
    Chen, Yanxiong
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2019, 19 (04) : 967 - 980
  • [50] Seismic behavior of superimposed reinforced concrete shear walls with X-shaped steel plate bracings under different axial load ratios
    Wang, Mengfu
    Guo, Shengqi
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2021, 30 (16):