Analytical Quality by Design-Compliant Development of a Cyclodextrin-Modified Micellar ElectroKinetic Chromatography Method for the Determination of Trimecaine and Its Impurities

被引:3
|
作者
Marzullo, Luca [1 ]
Gotti, Roberto [2 ]
Orlandini, Serena [1 ]
Slavickova, Patricie [3 ]
Jires, Jakub [3 ,4 ]
Zapadlo, Michal [3 ]
Dousa, Michal [3 ]
Nekvapilova, Pavla [4 ]
Rezanka, Pavel [4 ]
Furlanetto, Sandra [1 ]
机构
[1] Univ Florence, Dept Chem U Schiff, I-50019 Sesto Fiorentino, Italy
[2] Univ Bologna, Dept Pharm & Biotechnol, I-40126 Bologna, Italy
[3] Zentiva k s, Prague 10237, Czech Republic
[4] UCT Prague, Fac Chem Engn, Dept Analyt Chem, Prague 16628, Czech Republic
来源
MOLECULES | 2023年 / 28卷 / 12期
关键词
capillary electrophoresis; experimental design; impurities; method operable design region; quality by design; trimecaine; LOCAL-ANESTHETICS; CAPILLARY; PHARMACEUTICALS; PLASMA;
D O I
10.3390/molecules28124747
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In 2022, the International Council for Harmonisation released draft guidelines Q2(R2) and Q14, intending to specify the development and validation activities that should be carried out during the lifespan of an analytical technique addressed to assess the quality of medicinal products. In the present study, these recommendations were implemented in Capillary Electrophoresis method development for the quality control of a drug product containing trimecaine, by applying Analytical Quality by Design. According to the Analytical Target Profile, the procedure should be able to simultaneously quantify trimecaine and its four impurities, with specified analytical performances. The selected operative mode was Micellar ElectroKinetic Chromatography employing sodium dodecyl sulfate micelles supplemented with dimethyl-& beta;-cyclodextrin, in a phosphate-borate buffer. The Knowledge Space was investigated through a screening matrix encompassing the composition of the background electrolyte and the instrumental settings. The Critical Method Attributes were identified as analysis time, efficiency, and critical resolution values. Response Surface Methodology and Monte Carlo Simulations allowed the definition of the Method Operable Design Region: 21-26 mM phosphate-borate buffer pH 9.50-9.77; 65.0 mM sodium dodecyl sulfate; 0.25-1.29% v/v n-butanol; 21-26 mM dimethyl-& beta;-cyclodextrin; temperature, 22 & DEG;C; voltage, 23-29 kV. The method was validated and applied to ampoules drug products.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Micellar electrokinetic chromatography method development for determination of impurities in Ritonavir
    Carvalho, Alexandre Zatkovskis
    El-Attug, Mohamed Nouri
    Zayed, Sahar Ebrahem
    Van Hove, Els
    Van Duppen, Joost
    Hoogmartens, Jos
    Van Schepdael, Ann
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 53 (05) : 1210 - 1216
  • [22] CYCLODEXTRIN-MODIFIED MICELLAR ELECTROKINETIC CHROMATOGRAPHY - SEPARATION OF HYDROPHOBIC AND ENANTIOMERIC COMPOUNDS
    TERABE, S
    MIYASHITA, Y
    ISHIHAMA, Y
    SHIBATA, O
    JOURNAL OF CHROMATOGRAPHY, 1993, 636 (01): : 47 - 55
  • [23] Enantiomeric and isomeric separation of pesticides by cyclodextrin-modified micellar electrokinetic chromatography
    Shea, D
    Penmetsa, KV
    Leidy, RB
    JOURNAL OF AOAC INTERNATIONAL, 1999, 82 (06) : 1550 - 1561
  • [24] Separation of doxorubicin and doxorubicinol by cyclodextrin-modified micellar electrokinetic capillary chromatography
    Eder, Angela R.
    Chen, Jennifer S.
    Arriaga, Edgar A.
    ELECTROPHORESIS, 2006, 27 (16) : 3263 - 3270
  • [25] SEPARATION OF HIGHLY HYDROPHOBIC COMPOUNDS BY CYCLODEXTRIN-MODIFIED MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    TERABE, S
    MIYASHITA, Y
    SHIBATA, O
    BARNHART, ER
    ALEXANDER, LR
    PATTERSON, DG
    KARGER, BL
    HOSOYA, K
    TANAKA, N
    JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01): : 23 - 31
  • [26] ENANTIOMERIC SEPARATION OF DINICONAZOLE AND UNICONAZOLE BY CYCLODEXTRIN-MODIFIED MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    FURUTA, R
    DOI, T
    JOURNAL OF CHROMATOGRAPHY A, 1994, 676 (02) : 431 - 436
  • [27] Chiral separation of vinpocetine using cyclodextrin-modified micellar electrokinetic chromatography
    Ibrahim, Wan Aini Wan
    Abd Wahib, Siti Munirah
    Hermawan, Dadan
    Sanagi, Mohd Marsin
    Aboul-Enein, Hassan Y.
    CHIRALITY, 2012, 24 (03) : 252 - 254
  • [28] Simultaneous determination of free and conjugated bile acids in serum by cyclodextrin-modified micellar electrokinetic chromatography
    Tripodi, VP
    Lucangioli, SE
    Scioscia, SL
    Carducci, CN
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01): : 147 - 155
  • [29] Validation and Further Optimisation of a Cyclodextrin-Modified Micellar Electrokinetic Capillary Chromatography Method for Urine Profiling
    Ch. Guillo
    D. Perrett
    M. Hanna-Brown
    Chromatographia, 2004, 59 : S157 - S164
  • [30] Validation and further optimisation of a cyclodextrin-modified micellar electrokinetic capillary chromatography method for urine profiling
    Guillo, C
    Perrett, D
    Hanna-Brown, M
    CHROMATOGRAPHIA, 2004, 59 (Suppl 2) : S157 - S164