Feature Fusion for Multi-Coil Compressed MR Image Reconstruction

被引:0
|
作者
Cheng, Hang [1 ]
Hou, Xuewen [2 ]
Huang, Gang [3 ]
Jia, Shouqiang [4 ]
Yang, Guang [5 ]
Nie, Shengdong [1 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai 200093, Peoples R China
[2] Shanghai United Imaging Healthcare Co Ltd, Radiotherapy Business Unit, Shanghai 201807, Peoples R China
[3] Shanghai Univ Med & Hlth Sci, Shanghai Key Lab Mol Imaging, Shanghai 201318, Peoples R China
[4] Shandong First Med Univ, Jinan Peoples Hosp, Dept Radiol, Shandong 271199, Jinan, Peoples R China
[5] E China Normal Univ, Dept Phys, Shanghai Key Lab Magnet Resonance, Shanghai 200062, Peoples R China
来源
JOURNAL OF IMAGING INFORMATICS IN MEDICINE | 2024年 / 37卷 / 04期
关键词
MRI reconstruction; Deep learning; Multi-coil feature extraction; Feature fusion; NETWORKS; SENSE;
D O I
10.1007/s10278-024-01057-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) occupies a pivotal position within contemporary diagnostic imaging modalities, offering non-invasive and radiation-free scanning. Despite its significance, MRI's principal limitation is the protracted data acquisition time, which hampers broader practical application. Promising deep learning (DL) methods for undersampled magnetic resonance (MR) image reconstruction outperform the traditional approaches in terms of speed and image quality. However, the intricate inter-coil correlations have been insufficiently addressed, leading to an underexploitation of the rich information inherent in multi-coil acquisitions. In this article, we proposed a method called "Multi-coil Feature Fusion Variation Network" (MFFVN), which introduces an encoder to extract the feature from multi-coil MR image directly and explicitly, followed by a feature fusion operation. Coil reshaping enables the 2D network to achieve satisfactory reconstruction results, while avoiding the introduction of a significant number of parameters and preserving inter-coil information. Compared with VN, MFFVN yields an improvement in the average PSNR and SSIM of the test set, registering enhancements of 0.2622 dB and 0.0021 dB respectively. This uplift can be attributed to the integration of feature extraction and fusion stages into the network's architecture, thereby effectively leveraging and combining the multi-coil information for enhanced image reconstruction quality. The proposed method outperforms the state-of-the-art methods on fastMRI dataset of multi-coil brains under a fourfold acceleration factor without incurring substantial computation overhead.
引用
收藏
页码:1969 / 1979
页数:11
相关论文
共 50 条
  • [31] Development of single and multi-coil MR damper subjected to cyclic loading for structural vibration control
    Cruze, Daniel
    Krishnaraju, Nedunchezhian
    Ramalingam, Balaji
    ADVANCES IN CIVIL AND ARCHITECTURAL ENGINEERING, 2024, 15 (29): : 106 - 119
  • [32] Evaluation of the seismic performance of a multi-coil MR damper using non-linear method
    Daniel, C.
    Sharma, S. Vivekananda
    Hemalatha, G.
    Arunraj, E.
    STRUCTURES, 2024, 70
  • [33] A MR Image Sparse Reconstruction Method Based on Compressed Sensing
    Sun, Nan
    Dai, Qi
    NINTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2017), 2017, 10420
  • [34] Image reconstruction using compressed sensing for individual and collective coil methods
    Qureshi, Mahmood
    Junaid, Muhammad
    Najam, Asadullah
    Bashir, Daniyal
    Ullah, Irfan
    Kaleem, Muhammad
    Omer, Hammad
    BIOMEDICAL RESEARCH-INDIA, 2016, 27 : S287 - S292
  • [35] The Public Multi-Coil Information (PUMCIN) Policy
    Juchem, Christoph
    de Graaf, Robin A.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 2042 - 2047
  • [36] Analysis of Multi-Coil Omnidirectional Energy Harvester
    Tian, Xiaoyang
    Chau, K. T.
    Liu, Wei
    Lee, Christopher H. T.
    IEEE TRANSACTIONS ON MAGNETICS, 2021, 57 (02)
  • [37] Design optimization of multi-coil resistive magnets
    Prestemon, S
    Gilmore, P
    Gao, BJ
    Bird, MD
    IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (04) : 2550 - 2553
  • [38] Improvement of MR Image Resolution by Single Coil Multiple Image Reconstruction Technique
    Liu, Na.
    Ito, Satoshi
    Yamada, Yoshifumi
    Kasuga, Masao
    Tanaka, Kunio
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1455 - +
  • [39] The effect of coil polarity on electromagnetic forming using a multi-coil system
    Zhipeng Lai
    Quanliang Cao
    Meng Chen
    Ning Liu
    Xiaoxiang Li
    Yujie Huang
    Xiaotao Han
    Liang Li
    The International Journal of Advanced Manufacturing Technology, 2019, 103 : 1555 - 1566
  • [40] An iterative method for coil sensitivity estimation in multi-coil MRI systems
    Ling, Qiang
    Li, Zhaohui
    Song, Kaikai
    Li, Feng
    MAGNETIC RESONANCE IMAGING, 2014, 32 (10) : 1365 - 1376