Electrochemical investigation on naproxen sensing and steady-state diffusion analysis using Ni-Fe layered double hydroxide modified gold electrode

被引:5
|
作者
Muruganandam, Girdega [1 ]
Srinivasan, Soorya [2 ]
Nesakumar, Noel [1 ,3 ,6 ]
Hariharan, G. [4 ,6 ]
Gunasekaran, Balu Mahendran [5 ]
机构
[1] SASTRA Deemed Univ, Sch Chem & Biotechnol SCBT, Thanjavur 613401, Tamil Nadu, India
[2] Bharathidasan Univ, TBML Coll, PG & Res Dept Phys, Poraiyar 609307, Tamil Nadu, India
[3] SASTRA Deemed Univ, Ctr Nanotechnol & Adv Biomat CeNTAB, Thanjavur 613401, Tamil Nadu, India
[4] SASTRA Deemed Univ, Sch Humanities & Sci, Thanjavur 613401, Tamil Nadu, India
[5] Bharathidasan Univ, AVVM Sri Pushpam Coll Autonomous, Dept Chem, Thanjavur 613503, Tamil Nadu, India
[6] SASTRA Deemed Univ, Sch Chem & Biotechnol, Thanjavur 613401, Tamil Nadu, India
关键词
Naproxen; NiFe Layered double hydroxide; Electrodeposition; Modified gold electrode; Electrochemical sensor; CARBON NANOTUBES; SENSOR; HYBRID;
D O I
10.1016/j.measurement.2023.113389
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Naproxen, a nonsteroidal anti-inflammatory drug commonly used to treat various types of arthritis, including osteoarthritis, juvenile arthritis, and rheumatoid arthritis, has been associated with serious gastrointestinal and kidney complications. To address this issue, a long-lasting electrochemical sensor capable of sensitively and rapidly detecting naproxen has been developed. The sensor was fabricated by electrodepositing nickel-iron layered double hydroxide (NiFe LDH) on the surface of gold electrode, utilizing ferric nitrate and nickel nitrate as precursors. The NiFe LDH thin film serves as an efficient sensing platform for naproxen determination, and its electrochemical performance was characterized using differential pulse voltammetry and amperometry. Impressively, the developed naproxen sensor boasts a wide dynamic detection range (1-307 & mu;M) and a remarkably low limit of detection of 0.32 & mu;M. Additionally, the NiFe LDH/Au electrode exhibited long-term operational stability of 28 days, rapid response time (<80 s), excellent selectivity, and good reproducibility (1.89% RSD). In addition, Hermite wavelet was employed to formulate the relationship between the steady-state concentration of naproxen and the distance from the electrode's surface. With these impressive attributes, the NiFe LDH modified Au electrode is a promising candidate for the development of a long-lasting and reliable naproxen sensor.
引用
收藏
页数:12
相关论文
共 35 条
  • [21] Simultaneous Electrochemical Determination of Catechol and Hydroquinone Using a Flower-Like Ni-Al Layered Double Hydroxide/Carbon Black Nanocomposite-Modified Electrode
    Liu, Zhenhua
    Liu, Qiangbing
    Liao, Dan
    Yu, Jingang
    Jiang, Xinyu
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (11)
  • [22] Ni-Al/layered double hydroxide/Ag nanoparticle composite modified carbon-paste electrode as a renewable electrode and novel electrochemical sensor for hydrogen peroxide
    Habibi, Biuck
    Azhar, Fahimeh Farshi
    Fakkar, Jhila
    Rezvani, Zolfaghar
    ANALYTICAL METHODS, 2017, 9 (12) : 1956 - 1964
  • [23] Low-cost and high-performance of a vertically grown 3D Ni-Fe layered double hydroxide/graphene aerogel supercapacitor electrode material
    Gao X.
    Lv H.
    Li Z.
    Xu Q.
    Liu H.
    Wang Y.
    Xia Y.
    Liu, Haimei (liuhm@shiep.edu.cn), 1600, Royal Society of Chemistry (06): : 107278 - 107285
  • [24] Low-cost and high-performance of a vertically grown 3D Ni-Fe layered double hydroxide/graphene aerogel supercapacitor electrode material
    Gao, Xiujiao
    Lv, Haipeng
    Li, Zhihong
    Xu, Qunjie
    Liu, Haimei
    Wang, Yonggang
    Xia, Yongyao
    RSC ADVANCES, 2016, 6 (109) : 107278 - 107285
  • [25] A novel non-enzymatic glucose electrochemical sensor based on CNF@Ni-Co layered double hydroxide modified glassy carbon electrode
    Fu, Rong
    Lu, Youlan
    Ding, Yaping
    Li, Li
    Ren, Zhongming
    Si, Xiaojing
    Wu, Qingsheng
    MICROCHEMICAL JOURNAL, 2019, 150
  • [26] Determination of methotrexate using carbon paste electrode modified with ionic liquid/Ni-Co layered double hydroxide nanosheets as a voltammetric sensor
    Jahani, Peyman Mohammadzadeh
    Nejad, Fariba Garkani
    Zaimbashi, Reza
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Beitollahi, Hadi
    ADMET AND DMPK, 2024, 12 (04): : 637 - 648
  • [27] Synthesis of Nitrogen-doped Carbon Nanocoils via One-step Acetonitrile Catalytic CVD using a Ni-Fe Layered Double Hydroxide as Catalyst Precursor
    Iwasaki, Tomohiro
    Tomisawa, Masashi
    Nakamura, Hideya
    Watano, Satoru
    CHEMICAL VAPOR DEPOSITION, 2013, 19 (10-12) : 323 - 326
  • [28] Highly Sensitive Electrochemical Detection of Chlorpromazine Using Broccoli-Like Copper-Aluminum-Layered Double Hydroxide-Modified Platinum Electrode
    Narayanan, Charuchitra Siva Sankara
    Srinivasan, Soorya
    Ls, Sivagaama Sundari
    Ezhilan, Madeshwari
    Nesakumar, Noel
    Gunasekaran, Balu Mahendran
    Hariharan, G.
    CHEMISTRYSELECT, 2024, 9 (42):
  • [29] Sensitive determination of kojic acid in tomato sauces using Ni-Fe layered double hydroxide synthesized through Fe-MIL-88 metal-organic framework templated route
    Yadav, Dharmendra Kumar
    Ganesan, Vellaichamy
    Gupta, Rupali
    Yadav, Mamta
    Rastogi, Pankaj Kumar
    JOURNAL OF CHEMICAL SCIENCES, 2020, 132 (01)
  • [30] Life cycle assessment of chitosan modified Ni-Fe layered double hydroxide for arsenic(<sc>iii</sc>) sequestration in aqueous medium: comparison of the impacts of adsorbent recycling, instrument use and source of energy
    Bisaria, Kavya
    Seth, Chandra Shekhar
    Singh, Rachana
    ENVIRONMENTAL SCIENCE-ADVANCES, 2024, 3 (08): : 1153 - 1162