Plasma Electrolytic Oxidation for Dental Implant Surface Treatment

被引:1
|
作者
Muraev, A. A. [1 ]
Murzabekov, A. I. [2 ]
Ivanov, S. Yu. [1 ,3 ]
Tarasov, Yu. V. [4 ]
Orlov, E. A. [4 ]
Dolgalev, A. A. [5 ]
机构
[1] RUDN Univ, Peoples Friendship Univ Russia, 6 Miklukho Maklaya St, Moscow 117198, Russia
[2] Polyclin Presidential Adm Russian Federat, Cent Clin Hosp, 15 Marshal Timoshenko St, Moscow 121359, Russia
[3] IM Sechenov First Moscow State Med Univ, 8-2 Trubetskaya St, Moscow 119991, Russia
[4] Skolkovo Innovat Ctr, Beta Tech Med LLC, Bldg 1,42 Bolshoy Blvd, Moscow 121205, Russia
[5] Stavropol State Med Univ, 310 Mira St, Stavropol 355017, Russia
关键词
dental implant; osteointegration; implant surface treatment techniques; plasma electrolytic oxidation; hydroxyapatite; calcium hydroxyphosphate; TITANIUM-ALLOY; ROUGHNESS;
D O I
10.17691/stm2023.15.3.02
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Current technologies of plasma electrolytic oxidation (PEO) for modifying the surfaces of dental implants made of the Grade IV titan alloy provide predictable long-term results in implant dentistry. The aim of the study is to evaluate the efficacy of PEO technology comparing two types of surface modification of dental implants made of VT1-0 medical titanium alloy. Materials and Methods. 50 IRIS dental implants (Scientific Production Company LICOSTOM, Russia), 10-mm long and 4 mm in diameter, were manufactured from the VT1-0 alloy. The implant surface was treated by two PEO methods: 1) in the aqueous solution of alkaline electrolyte without any additional modifiers (PEO- Ti); 2) in the aqueous solution of orthophosphoric acid-based electrolyte containing calcium carbonate (PEO-Ca). Implants made of VT1-0 alloy after milling and without additional treatment served as control samples. The implant surfaces were studied by electron microscopy and energy dispersive X-ray spectrometry. Some of the implants were installed in sheep, samples were obtained at 2, 4, and 8 weeks and studied by microcomputer tomography. Results. Regardless of the electrolyte composition, a highly developed porous surface was formed in the samples with PEO-modified surfaces. The surface of the PEO-Ti samples in a simple unmodified electrolyte was characterized by a large number of open pores with a wide range of size distribution from 200 nm to 3 mu m. The pore size distribution was of a monomodal character, with a maximum near 0.23 mu m. The PEO samples in the Ca-containing electrolyte had pores also in a wide range from similar to 80 nm to similar to 7 mu m. The pore distribution, in contrast to PEO- Ti, was bimodal in nature, with the main maximum in the region of 1.05 mu m and the concomitant maximum near 2.45 mu m. The obtained surfaces of both types (PEO with Ca and Ti) possessed high purity and optimal microroughness for osseointegration. Both types of PEO treatment (PEO with Ca and Ti) have demonstrated a similar osseointegrative potential, nevertheless, the surface of the PEO-Ca showed a better contact with the implant surface (49.8%) than PEO-Ti (42.4%) obviously due to the presence of calcium in its composition. Conclusion. The PEO-formed implant surfaces demonstrate high osseointegrative properties after any variants of treatment and show the potential for application in osteoporosis.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 50 条
  • [31] Magnetic properties of surface layers formed on titanium by plasma electrolytic oxidation
    S. V. Gnedenkov
    S. L. Sinebryukhov
    I. A. Tkachenko
    D. V. Mashtalyar
    A. Yu. Ustinov
    A. V. Samokhin
    Yu. V. Tsvetkov
    Gnedenkov, S.V. (svg21@hotmail.com), 1600, Maik Nauka Publishing / Springer SBM (03): : 151 - 156
  • [32] Anodising and Plasma Electrolytic Oxidation for the Surface Modification of Aluminium Alloys: Review
    Sahoo, Baidehish
    Das, Tannnoy
    Paul, Jinu
    JOURNAL OF SURFACE SCIENCE AND TECHNOLOGY, 2021, 37 (1-2) : 1 - 14
  • [33] Effect of plasma electrolytic oxidation process on surface characteristics and tribological behavior
    Cai, Ran
    Zhao, Chen
    Nie, Xueyuan
    SURFACE & COATINGS TECHNOLOGY, 2019, 375 : 824 - 832
  • [34] Dental Implant Surface Decontamination and Surface Change of an Electrolytic Method versus Mechanical Approaches: A Pilot In Vitro Study
    Assuncao, Mariana Anselmo
    Botelho, Joao
    Machado, Vanessa
    Proenca, Luis
    Matos, Antonio P. A.
    Mendes, Jose Joao
    Bessa, Lucinda J. J.
    Taveira, Nuno
    Santos, Alexandre
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (04)
  • [35] Modification of tantalum surface via plasma electrolytic oxidation in silicate solutions
    Sowa, Maciej
    Kazek-Kesik, Alicja
    Socha, Robert P.
    Dercz, Grzegorz
    Michalska, Joanna
    Simka, Wojciech
    ELECTROCHIMICA ACTA, 2013, 114 : 627 - 636
  • [36] Effect of surface nanostructuring of aluminum alloy on post plasma electrolytic oxidation
    Masiha, H. R.
    Bagheri, H. R.
    Gheytani, M.
    Aliofkhazraei, M.
    Rouhaghdam, A. Sabour
    Shahrabi, T.
    APPLIED SURFACE SCIENCE, 2014, 317 : 962 - 969
  • [37] Achieving surface chemical and morphologic alterations on tantalum by plasma electrolytic oxidation
    Marcelo Augusto Pinto Cardoso Goularte
    Gustavo Frainer Barbosa
    Nilson Cristino da Cruz
    Luciana Mayumi Hirakata
    International Journal of Implant Dentistry, 2 (1)
  • [38] Influences of urea and sodium nitrite on surface coating of plasma electrolytic oxidation
    Yeh, Shang-Chun
    Tsai, Dah-Shyang
    Guan, Sheng-Yong
    Chou, Chen-Chia
    APPLIED SURFACE SCIENCE, 2015, 356 : 135 - 141
  • [39] The effects of different bioceramics-incorporated oxide films on titanium implant by plasma electrolytic oxidation
    Sakiru Adekunle Adeleke
    Journal of Materials Research, 2022, 37 : 4348 - 4359
  • [40] The effects of different bioceramics-incorporated oxide films on titanium implant by plasma electrolytic oxidation
    Adeleke, Sakiru Adekunle
    JOURNAL OF MATERIALS RESEARCH, 2022, 37 (23) : 4348 - 4359