Accuracy of implant site preparation in robotic navigated dental implant surgery

被引:21
|
作者
Linn, Thu Ya [1 ]
Salamanca, Eisner [1 ]
Aung, Lwin Moe [1 ]
Huang, Ta-Ko [2 ,3 ]
Wu, Yi-Fan [1 ]
Chang, Wei-Jen [1 ,4 ]
机构
[1] Taipei Med Univ, Coll Oral Med, Sch Dent, Taipei, Taiwan
[2] Kaohsiung Med Univ, Sch Dent, Kaohsiung, Taiwan
[3] EPED Inc, Kaohsiung, Taiwan
[4] Taipei Med Univ, Shuang Ho Hosp, Dent Dept, New Taipei City, Taiwan
关键词
digital dentistry; implant drilled socket; implantology; radiographs; surgical; techniques; DYNAMIC NAVIGATION; PLACEMENT; SYSTEM;
D O I
10.1111/cid.13224
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundModern technological advancements have led to increase in the development of surgical robots in dentistry, resulting in excellent clinical treatment outcomes. PurposeThis study aimed to determine the accuracy of automatic robotic implant site preparation for different implant sizes by correlating planned and posttreatment positions, and to compare the performance of robotic and human freehand drilling. MethodSeventy-six drilling sites on partially edentulous models were used, with three different implant sizes (o = 3.5 x 10 mm, 4.0 x 10 mm, 5.0 x 10 mm). The robotic procedure was performed using software for calibration and step-by-step drilling processes. After robotic drilling, deviations in the implant position from the planned position were determined. The angulation, depth, and coronal and apical diameters on the sagittal plane of sockets created by human and robotic drilling were measured. ResultsThe deviation of the robotic system was 3.78 degrees +/- 1.97 degrees (angulation), 0.58 +/- 0.36 mm (entry point), and 0.99 +/- 0.56 mm (apical point). Comparison of implant groups showed the largest deviation from the planned position for 5 mm implants. On the sagittal plane, there were no significant differences between robotic and human surgery except for the 5-mm implant angulation, indicating similar quality between human and robotic drilling. Based on standard implant measurements, robotic drilling exhibited comparable performance to freehand human drilling. ConclusionsA robotic surgical system can provide the greatest accuracy and reliability regarding the preoperative plan for small implant diameters. In addition, the accuracy of robotic drilling for anterior implant surgery can also be comparable to that of human drilling.
引用
收藏
页码:881 / 891
页数:11
相关论文
共 50 条
  • [1] Accuracy of an autonomous dental implant robotic system in dental implant surgery
    Wu, Yu
    Zou, Shiqi
    Lv, Pin
    Wang, Xiao
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 764 - 770
  • [2] Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches
    Bolding, Scotty L.
    Reebye, Uday N.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 639 - 647
  • [3] Dental Implant Surgery: From Conventional to Guided to Navigated Approach
    Kasten B.
    Arastu A.
    Panchal N.
    Current Oral Health Reports, 2018, 5 (2) : 140 - 146
  • [4] Accuracy of robotic surgery for dental implant placement: A systematic review and meta-analysis
    Wu, Xin-Yu
    Shi, Jun-Yu
    Qiao, Shi-Chong
    Tonetti, Maurizio S.
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) : 598 - 608
  • [5] Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study
    Tao, Baoxin
    Feng, Yuan
    Fan, Xingqi
    Zhuang, Minjie
    Chen, Xiaojun
    Wang, Feng
    Wu, Yiqun
    JOURNAL OF DENTISTRY, 2022, 123
  • [6] Accuracy of an autonomous dental implant robotic system versus static guide-assisted implant surgery: A retrospective clinical study
    Jia, Shasha
    Wang, Guowei
    Zhao, Yimin
    Wang, Xiaojing
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 771 - 779
  • [7] Accuracy of mucosa supported guided dental implant surgery
    Jones, Andoni
    CLINICAL CASE REPORTS, 2018, 6 (11): : 2131 - 2139
  • [8] Accuracy of dental implant surgery with robotic position feedback and registration algorithm: An in-vitro study
    Cheng, Kang-jie
    Kan, Tian-shu
    Liu, Yun-feng
    Zhu, Wei-dong
    Zhu, Fu-dong
    Wang, Wei-bin
    Jiang, Xian-feng
    Dong, Xing-tao
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 129
  • [9] Assessment of accuracy of navigated implant placement in the maxilla
    Gaggl, A
    Schultes, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (02) : 263 - 270
  • [10] Optics-guided Robotic System for Dental Implant Surgery
    Biao Yan
    Wenlong Zhang
    Lijing Cai
    Lingxiang Zheng
    Kaiyang Bao
    Yuming Rao
    Lin Yang
    Weitao Ye
    Peifeng Guan
    Wei Yang
    Jiang Li
    Rongqian Yang
    Chinese Journal of Mechanical Engineering, 2022, 35 (03) : 149 - 161